Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Tashkent state dental institute | UNKNOWN |
| I.M. Sechenov First Moscow State Medical University | OTHER |
| Pirogov Russian National Research Medical University | OTHER |
Not provided
Not provided
Not provided
Not provided
Purpose of study is to assess perioperative functional parameters of the anterior abdominal wall muscles and postural control status in patients with large and giant incisional hernias in a controlled diagnostic study.
The study involved 95 patients (100% completed) with a large or giant incisional hernia of the anterior abdominal wall. The participants were divided into three groups by type of hernia repair: bridged hernia repair, Rives-Stoppa procedure, or TAR technique. Perioperative functional parameters of the anterior abdominal wall muscles were assessed by tension dynamometry. The postural balance assessments were made by raster photostereography.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group I | Active Comparator | 32 patients who underwent classic abdominal wall anterior components separation and bridged hernia repair. |
|
| Group II | Active Comparator | 34 patients who underwent posterior components separation with the internal oblique myofascial release by Rives-Stoppa |
|
| Group III | Active Comparator | 29 patients who underwent posterior components separation with transversus abdominis release (TAR). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Dynamometric tension assessment | Diagnostic Test | Tension dynamometry was carried out using the "Back-Check 600" diagnostic complex by Dr.WOLFF® (GmbH, Germany). The dynamometric stress assessment included tasks for flexion and extension of the body. The functional assessment of the abdominal wall muscles was assessed when preparing the patient for surgery (1-10 days before AWR-abdominal wall reconstruction) and 6 months after AWR. |
| Measure | Description | Time Frame |
|---|---|---|
| Diagnostic accuracy | Sensitivity and specificity | 1-2 weeks before surgical treatment and 6 months after reconstructive hernioplasty of postoperative ventral hernia |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Otabek J. Eshonkhodjaev, MD, PhD | Republican specialiazed scientific practical medical center of surgery named after V.V. Vakhidov | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Republican specialized scientific practical medical center of surgery named after V.V. Vakhidov | Tashkent | 100100 | Uzbekistan |
Not provided
Not provided
Not provided
Not provided
Not provided
Cohort study
Not provided
Not provided
Not provided
|
|
| Postural balance | Diagnostic Test | Postural balance was assessed using raster photostereography and baropodometry on the "DIERS" diagnostic complex by Formetric-4D (GmbH, Germany). When analyzing the topography of the optical field, muscle imbalance is revealed in the form of lateral deviation and inclination of the trunk and pelvis, as well as the values of the angle of kyphosis and lordosis. When conducting baropodometry, the level of displacement of the pressure area on the feet of patients in a static and dynamic position was assessed. Diagnosis of postural balance in patients with incisional ventral hernia was performed a few days before surgical treatment and 6 months after AWR. |
|
|
| Assessment of the hernia defect size | Diagnostic Test | Parameters of the hernial defect, including the volume of the hernial sac, the diameter of the hernial orifice, the ratio of hernia volume to the abdominal cavity volume, were performed using preoperative (1-10 days before AWR) multispiral computed tomography on a GE "BrightSpeed 16" tomograph (General Electric©, USA) |
|
| Physical activity of patients | Diagnostic Test | To analyze the physical activity of patients, the measurement of the number of steps was used. The measurements of steps and the amount of distance traveled were carried out using a physical activity monitor - a fitness bracelet "MiBAND" (China). Measurements were taken 10 days before AWR and within 6 months after AWR. |
|
|
| ID | Term |
|---|---|
| D000069290 | Incisional Hernia |
| ID | Term |
|---|---|
| D006547 | Hernia |
| D020763 | Pathological Conditions, Anatomical |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D011183 | Postoperative Complications |
| D010335 | Pathologic Processes |
Not provided
Not provided
| ID | Term |
|---|---|
| D004856 | Postural Balance |
| ID | Term |
|---|---|
| D011434 | Proprioception |
| D000084323 | Vestibulocochlear Physiological Phenomena |
| D010829 | Physiological Phenomena |
| D009142 | Musculoskeletal Physiological Phenomena |
| D055687 | Musculoskeletal and Neural Physiological Phenomena |
| D012677 | Sensation |
| D009424 | Nervous System Physiological Phenomena |
Not provided
Not provided