The purpose of this study is to test the Fluispotter® technology: A novel system for collection of serial venous samples, which may overcome some of the problems associated with repeated sampling or 20-hour collection of blood samples using standard procedures. The Fluispotter® is the first fully automated, wearable device for obtaining serial blood samples from humans. It is designed to function without operator intervention. The wearable device and - when in place - painless sampling allow sampling during different situations e.g., during sleep, work, play or exercise - whatever the sampling situation requires, including sampling not possible today using wet samples e.g. during everyday activities. Further, it reduces the number of man-hours needed for serial sampling, and minimizes the risks of sample loss, wrong timing, misidentification and contamination.
The primary purpose of this investigator-initiated study is to assess the feasibility, including benefits and harms, of the Fluispotter®, a novel method for serial blood sampling, versus standard blood sampling. The planned setting is a test of the Fluispotter® is a 20-hour period in healthy adults and in adults with secondary adrenal insufficiency due to pituitary disease.
Background In an every-day endocrine setting the dynamic response of hormones is assessed for the diagnosis and evaluation of several conditions such as adrenal insufficiency, Cushing's disease, acromegaly, and growth hormone insufficiency. These procedures require repeated venous sampling. A novel system for collection of serial samples, the Fluispotter®, may overcome some of these problems associated with repeated sampling or 20-hour collection of blood samples. The Fluispotter® is the first fully automated, wearable device for obtaining serial blood samples from humans. It is designed to function without operator intervention. The wearable device and - when in place - painless sampling allow sampling during different situations e.g., during sleep, work, play or exercise - whatever the sampling situation requires, including sampling not possible today using wet samples e.g. during everyday activities. Further, it reduces the number of man-hours needed for serial sampling, and minimizes the risks of sample loss, wrong timing, misidentification and contamination. The dried blood spot technology used in the Fluispotter® was tested for cortisol by comparing with plasma samples and the interassay accuracy and precision were reported to less than 10% across a range of different haematocrit values.
Aim The primary purpose of this investigator-initiated study is to assess the feasibility, including benefits and harms, of the Fluispotter®, a novel method for serial blood sampling, versus standard blood sampling. The planned setting is a test of the Fluispotter® is a 20-hour period in healthy adults and in adults with secondary adrenal insufficiency due to pituitary disease.
The primary outcome for this study is feasibility. This will be assessed using a standardized questionnaire for both staff and participants including items regarding duration of the insertion procedure, ease of insertion, number of re-insertions during the 20-hour study, number of occlusions. Participants will also be asked about perception of pain during insertion, overall acceptance of insertion, acceptance of catheter during the 20-hour admission, and for an overall preference between the new method and conventional blood sampling. In addition, participants will be contacted one week after admission regarding problems related to catheter insertion such as haematomas, pain, infection.
Secondary outcomes will be to assess the validity of cortisol concentrations measured by Dried Blood Spot technology, i.e. the Fluispotter®, compared to the standard blood sampling technique in a clinical setting. Also, Study 1 will compare diurnal cortisol profiles in healthy adults and patients with secondary adrenal insufficiency as well as assessing if the Fluispotter® performs the planned sampling.
Participants In Study 1 a total of 20 individuals will be included, 10 of whom (5 healthy women and 5 healthy men) will constitute the healthy adults and will be recruited through media advertisements.
Five women and 5 men diagnosed with secondary adrenal insufficiency due to pituitary disease will be recruited as patients.These 10 participants will constitute the patient group
The intervention takes place at the Department of Endocrinology and Metabolism at Rigshospitalet, Copenhagen, Denmark.
Sampling Sampling from the Fluispotter® is automatic and does not require attendance from staff. The Fluispotter® will be programmed for 20 samplings at 11:00 am, 13:00 p.m., 17:00 p.m., 21:00 p.m., 23:00 p.m., 00:50 a.m., 02:00 a.m., 02:50 a.m., 04:00 a.m., 04:30 a.m., 05:00 a.m., 05:30 a.m., 06:00 a.m., 06:15 a.m., 06:30 a.m., 06:45 a.m., 07:00 a.m., 07:15 a.m., 07:30 a.m. and 08:00 a.m. The cassettes containing the dried blood spots will be stored at -80◦C until analysis.
Also, eighteen samples from the venous catheter will be drawn at 11:00 am, 13:00 p.m., 17:00 p.m., 21:00 p.m., 23:00 p.m., 01:00 a.m., 03:00 a.m., 04:00 a.m., 04:30 a.m., 05:00 a.m., 05:30 a.m., 06:00 a.m., 06:15 a.m., 06:30 a.m., 06:45 a.m., 07:00 a.m., 07:15 a.m., 07:30 a.m. and 08:00 a.m.
One week after admission the patients will be scheduled for a post-intervention interview. At this visit the patients' arms will be checked for haematomas and the patients will be asked about possible health problems occurring which have arisen after the admission.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients with adrenal insufficiency | 10 patients with adrenal insufficiency due to pituitary desease will be recruited for this arm. |
| |
| Healthy controls | 10 healthy controls will be recruited for this arm. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Fluispotter® | Device | The Fluispotter® has been developed for automated extraction, collection and storage of up to 20 dried venous dried blood spot samples of 3-10 μl over the course of up to 20 hours. The system is attached to the patient through a multilumen microcatheter inserted into a peripheral vein in the arm. The Fluispotter will be inserted in both healthy subjects and patients with adrenal insufficiency. |
| Measure | Description | Time Frame |
|---|---|---|
| Feasibility - subjects | Subjects' acceptance of device - Assessed by a questionnaire consisting of 11 questions designed for this study | Day 2-7 |
| Measure | Description | Time Frame |
|---|---|---|
| Number of succesfull samples by the Fluispotter | The Fluispotter is designed to collect 20 samples during 20 hours. This outcome will describe have many succesful samples the Fluispotter on average performed. | Day 2 |
| Feasibility - operator |
| Measure | Description | Time Frame |
|---|---|---|
| Increase of cortisol due to sampling stress | The samples obtained from the Fluispotter willl be compared with wet samples prior to and after collection of samples. Any difference could be attribued to sampling stress. | through study completion, an average of 1 year |
Healthy subjects
Inclusion Criteria:
Patients Inclusion criteria
Not provided
Not provided
Patients with secondary pituitary insufficiency
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Ulla Feldt-Rasmussen, Professor | Contact | +45 35 45 10 23 | ufeldt@rh.dk | |
| Jesper Krogh, Ass. Prof | Contact | +45 25 53 54 85 | jesper.krogh.01@regionh.dk |
| Name | Affiliation | Role |
|---|---|---|
| Ulla Feldt-Rasmussen, Prof | Rigshospitalet, Denmark | Principal Investigator |
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 35038558 | Background | Ollerenshaw JD, Schroder M, Velschow S. A novel device for serial venous blood sampling in a canine model. J Pharmacol Toxicol Methods. 2022 Mar-Apr;114:107155. doi: 10.1016/j.vascn.2022.107155. Epub 2022 Jan 14. | |
| 32489105 | Background | Adhikari KB, Rohde M, Velschow S, Feldt-Rasmussen U, Johannesen J, Johnsen AH. Fluispotter, a novel automated and wearable device for accurate volume serial dried blood spot sampling. Bioanalysis. 2020 May;12(10):665-681. doi: 10.4155/bio-2020-0048. Epub 2020 Jun 3. |
Not provided
Not provided
There are currently no plan to share IPD with other researchers
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000309 | Adrenal Insufficiency |
| ID | Term |
|---|---|
| D000307 | Adrenal Gland Diseases |
| D004700 | Endocrine System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
hormone measurements
|
How did the anesthesiologist inserting the Fluispotter catheter percieve the feasibility of the device - Assessed by a questionnaire (uploaded)
| Day 1 |