This is a single-center, open-label, prospective study. Blood glucose was measured at different time points during oral glucose tolerance testing in patients with type 2 diabetes mellitus, using both venous plasma and multi-channel microspatial offset Raman scattering spectroscopy (mμSORS). Venous plasma glucose was set as gold standard.The two measurements were collected synchronously so as to calculate the mean absolute relative difference (MARD) and the consensus error grid (CEG). Accuracy of non-invasive blood glucose testing by mμSORS will be validated. MARD for two measurement methods in different blood glucose ranges and the safety outcomes of mμSORS such as adverse events will also be assessed.
In order to clinically verify the accuracy and safety of non-invasive blood glucose measurement by the mμSORS technology, and to explore the feasibility of non-invasive detection in multi-indicators of mμSORS, this study will conduct an oral glucose tolerance test on patients with type 2 diabetes. There will be 12 collection points of blood samples as follows: 0-min and post glucose-load 15-minļ¼30-minļ¼45-minļ¼60-minļ¼75-minļ¼90-minļ¼105-minļ¼120-minļ¼135-minļ¼150-minļ¼ and 180-min. Approximately 4ml of whole blood was collected at each time point for venous plasma glucose and serum insulin measurement. The blood glucose value measured by mμSORS will be obtained synchronously at the above 12 time points.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Preclinical Research of mμSORS for Noninvasive Blood Glucose Detection | Experimental | Enrolled subjects will perform oral glucose tolerance test. A measurement session of blood glucose consists of plasma sample and a measurement by mμSORS will be conducted synchronously. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Multi-channel Microspatial Offset Raman Scattering Spectroscopy (mμSORS) for Noninvasive Blood Glucose Detection | Device | Blood glucose of participants were measured by venous plasma and multi-channel microspatial offset Raman scattering spectroscopy (mμSORS). The two measurements were collected synchronously and analyzed. |
| Measure | Description | Time Frame |
|---|---|---|
| Mean absolute relative deviation (MARD) of venous plasma glucose and glucose values measured by mμSORS at each time point of OGTT. | Glucose will be measured using both intravenous sampling (plasma) and multi-channel microspatial offset Raman scattering spectroscopy (mμSORS) detection synchronously. | Four months. |
| Consensus Error Grid (CEG) for venous plasma glucose and glucose values measured by mμSORS at each time point of OGTT. | Glucose will be measured using both intravenous sampling (plasma) and multi-channel microspatial offset Raman scattering spectroscopy (mμSORS) detection synchronously. | Four months. |
| Measure | Description | Time Frame |
|---|---|---|
| MARD for two measurement methods in different blood glucose ranges. | Plasma glucose ranges 3.9-10.0 mmol/L, <3.9 mmol/L and >10.0 mmol/L. | Four months. |
| Incidence of Treatment-Emergent Adverse Events |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Weiqing Wang, Dr. | Ruijin Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ruijin Hospital, Shanghai Jiao Tong University School of Medicine | Shanghai | Shanghai Municipality | 200025 | China |
Not provided
| ID | Term |
|---|---|
| D003924 | Diabetes Mellitus, Type 2 |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
Safety outcomes.
| Four months. |
| D004700 | Endocrine System Diseases |