Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Trainee Investigator did not come to institution.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This is a study to investigate if a device that temporarily changes brain activity (repetitive transcranial magnetic stimulation, rTMS) might be used to change how healthy participants make decisions. This study involves 2 visits to MUSC that will each take between 2-3 hours. This study is not a treatment study, but it could help inform studies investigating treatment in the future. Participants in this study will be compensated for their time.
This study aims to investigate whether a single session of excitatory repetitive transcranial magnetic stimulation (rTMS) compared to electrical sham stimulation to the medial prefrontal cortex (mPFC) facilitates rational decision making. Our prior data suggests that decisions are biased depending on if the available options are presented with a negative or positive connotation (even in the case of mathematical equivalence). Work by us and others has demonstrated that even if both options are equal, the negatively framed choice is most often avoided.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Real TBS to the mPFC | Experimental | The type of stimulation to be used will be intermittent theta burst (iTBS) stimulation to the mPFC with a figure 8 coil (Coil Cool-B65 A/P). Participants will receive three 3-minute sessions of iTBS (600 pulses; 190s; 120% resting motor threshold) with 10-15-minute breaks in between each session or more per participant preference. |
|
| Sham TBS to the mPFC | Sham Comparator | The MagVenture MagPro system has an integrated, active sham which passes current through two surface electrodes placed on the scalp. The electrodes will be placed on the left frontalis muscle for all sessions. A patient identification card will randomize participants to receive either sham or active stimulation in the first session.This system maintains blinding by a gyroscope in the coil which indicates to the clinical staff whether the coil should be rotated up or down for this participant once the card is entered into the machine. One side of the coil is active, the other is sham. The integrity of the double blind procedure will be assessed by asking the patients and study personnel rate their confidence regarding whether they thought they received real or sham. (Scale 1-10) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Real TBS to mPFC | Device | This will be delivered with the Magventure MagPro System; (double blinded using the integrated active sham system). |
|
| Measure | Description | Time Frame |
|---|---|---|
| Baratt Impulsiveness Scale | Change in 30-item self-report scale that is commonly used to measure impulsiveness. Participants respond to each item using a 4-point Likert scale: 1 (rarely/never), 2 (occasionally), 3 (often), and 4 (almost always/always). | Change assessed at visit 1 (day 1) and visit 2 (day 2) |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
• Current psychiatric disorder (as defined by DSM-5 and determined using standardized self-report instruments)
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Lisa McTeague, Ph.D. | Medical University of South Carolina | Principal Investigator |
Not provided
Not provided
Participants will be randomly assigned to receive active or sham stimulation either first or second. All participants will receive active and sham during the study, only the order will be randomized.
Not provided
Not provided
This study is double blinded. Both the investigators and the participants will be blinded as to which method of stimulation they receive first.
| Sham TBS to mPFC | Device | This will be delivered with the Magventure MagPro System; (double blinded using the integrated active sham system). The Magventure MagPro system has an integrated active sham that passes current through two surface electrodes placed on the scalp. The electrodes are placed on the left frontalis muscle under the coil for both the real and sham stimulation sessions. |
|