Nowadays, intraarterial catheterization is frequently used as an invasive method for intraoperative blood pressure monitoring and control.The radial artery is frequently used in this procedure and the cannula should be flushed with 2-3 ml of heparinized fluid intermittently to prevent occlusion. During the operation, the ambient temperature is approximately 22-24 C and the patient temperature can be 34-36 C. Since the flushing fluids are also in the environment, they are 22-24 C. The aim of this study is to determine whether the fluids at room temperature cause vasoconstriction in the vessel and cause a change in blood pressure arterial values.
The aim of this study is to determine whether room temperature fluids cause vasoconstriction or vasodilatation in the vessel and cause a change in blood pressure arterial values.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| room temperature washing solution | Active Comparator | İntra-arterial flushing with heparinized fluid kept in room air |
|
| washing solution at patient temperature | Active Comparator | Intra-arterial flushing with heparinized fluid at patient body temperature |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| intra-arterial flushing | Other | The catheter will be flushed to prevent occlusion after radial artery catheterization. intra-arterial flushing with heparinized fluid kept in room air |
| Measure | Description | Time Frame |
|---|---|---|
| Arterial flow velocities PSV | After flushing performed , peak systolic velocity (PSV) values in the radial artery by Ultrasound doppler method. | 30th seconds after arterial flush |
| Arterial flow velocities End-diastolic velocity | After flushing performed , end- diastolic velocity (EDV) values in the radial artery by ultrasound doppler method; | 30th seconds after arterial flush |
| Arterial flow velocities resistive indices | After flushing performed resistive indices (RI) values in the radial artery by ultrasound doppler method. | 30th seconds after arterial flush |
| Measure | Description | Time Frame |
|---|---|---|
| invasive and non-invasive blood pressure | After flushing performed systolic, diastolic, and average blood pressure values measured | 10th,30th,60th,90th ,120th and 150th seconds |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Korgün Ökmen, Assoc. PhD. | Contact | +905057081021 | korgunokmen@gmail.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Bursa Yuksek Ihtisas Training and Research Hospital | Bursa | 16110 | Turkey (Türkiye) |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| intra-arterial flushing | Other | Intra-arterial flushing with heparinized fluid at patient body temperature |
|
|