Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| National Science and Technology Council | FED |
| SEHA Kidney Care | UNKNOWN |
| Asia University Hospital | UNKNOWN |
Not provided
Not provided
Not provided
Not provided
Not provided
The global prevalence of end-stage renal disease (ESRD) was estimated ranging 5.3 to 9.7 million patients in 2017 and is a major healthcare cost driver in both developed and developing economies. The majority of patients with ESRD, approximately 90%, received in-center maintenance hemodialysis (HD). Although HD patients are under the close supervision of a nephrologist, they are vulnerable to anemia and substantial hemoglobin (Hb) variability, which are controversially associated with poor clinical outcomes, such as all-cause mortality. The contemporary narrow target hemoglobin level recommended in the KDIGO and KDOQI guidelines, despite the ongoing debates, poses a crucial challenge in maintaining the optimal hemoglobin level in HD patients.
The Big Data Center at China Medical University Hospital (CMUH) has developed a tool, Hb Scope APP, that can use the color of the HD tubing to predict real-time Hb levels by leveraging the smartphone's camera capacity and machine learning (ML) technology. The performance of the Hb Scope ML algorithm in predicting Hb > 10 g/dL can reach an accuracy of 0.93 and an AUROC of 0.99 in the testing dataset. This opens an opportunity to establish a vibrant digital ecosystem for automatic anemia management.
Innovative ML tools must be appropriately regulated before these algorithms are adopted into clinical practice. Therefore, in the current validation study, we propose to do a multicenter validation trial for validating whether the Hb predicted by Hb Scope APP can achieve an area under the receiver operating curve (AUROC) of at least 0.80 in the adult HD populations from CMUH, Asia University Hospital (AUH) in Taiwan, and SEHA Kidney Care (SKC)-Central in the United Arab Emirates.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| CMUH | Adult patients who receive maintenance hemodialysis through an arteriovenous (AV) fistula or AV graft access at CMUH. |
| |
| AUH | Adult patients who receive maintenance hemodialysis through an arteriovenous (AV) fistula or AV graft access at AUH. |
| |
| SKC-Central | Adult patients who receive maintenance hemodialysis through an arteriovenous (AV) fistula or AV graft access at SKC-Central. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Hb Scope APP | Other | The study intervention is the Hb Scope APP, a camera-based real-time Hb estimation tool using a data collection function and a machine learning-based algorithm to analyze the image of HD tubing and output the estimated Hb value. Our proposed Hb Scope APP can provide a non-invasive and real-time estimation of Hb level for detecting the alarming Hb status (i.e., <=10 g/dL) during every HD session. The software is for information management purposes only and is not intended for diagnostic use. |
| Measure | Description | Time Frame |
|---|---|---|
| Agreement between the lab-derived and the Hb Scope-derived Hb level at the dichotomous cutoff of > 10 g/dL. | The targeted area under the receiver operating curve (AUROC) is 0.80. | 2 months |
| Measure | Description | Time Frame |
|---|---|---|
| Agreement between the lab-derived and the Hb Scope-derived Hb level at the dichotomous cutoff of < 8 g/dL. | The targeted area under the receiver operating curve (AUROC) is 0.80. | 2 months |
| Agreement between the lab-derived and the Hb Scope-derived Hb level at the dichotomous cutoff of > 12 g/dL. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Gender identity
Adult patients receiving regular maintenance HD through an arteriovenous (AV) fistula or AV graft access in the three participating sites.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| China Medical University Hospital | Taichung | 404 | Taiwan | |||
| Asia University Hospital |
Will not make IPD available to other researchers.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
The targeted area under the receiver operating curve (AUROC) is 0.80. |
| 2 months |
| Consistency between the lab-derived and Hb Scope-derived Hb continuous value. | The targeted correlation coefficient is 0.70. | 2 months |
| Taichung |
| Taiwan |
| SHEA Kidney Care | Abu Dhabi | United Arab Emirates |