. 24 individuals were evaluated, with low back pain for more than 12 weeks and aged between 12 and 65 years. The current used in the lumbar region of the participants was of the tetrapolar interferential type and the stimulation mode was the automatic vector, carrier of 4,000 HZ, modulation frequency (AMF) of 50 HZ, sweep frequency of SWEEP of 20HZ. The assessment of pain and functionality was performed using the data collection instrument, the Visual Analogue Pain Scale (VAS), Rolland Morris Disability Questionnaire (RMDQ) and the Owestry Disability Questionnaire (ODQ) respectively. The present study demonstrates that treatment with interferential current promotes chemical improvement in participants, which opens up new perspectives on the use of this therapeutic approach.
Low back pain is characterized by pain and represents a change in health that affects mainly adults, although electrostimulation represents an important tool in the treatment of patients with chronic nonspecific low back pain, the clinical efficacy of the interferential current used in physiotherapy still lacks reinforcement for clinical validation. In this way, the present study evaluated whether the use of interferential current contributes to reducing chronic low back pain and analyzed whether the electrotherapeutic protocol can benefit the physical functionality of patients with chronic low back pain. 24 individuals were evaluated, with low back pain for more than 12 weeks and aged between 12 and 65 years. The current used in the lumbar region of the participants was of the tetrapolar interferential type and the stimulation mode was the automatic vector, carrier of 4,000 HZ, modulation frequency (AMF) of 50 HZ, sweep frequency of SWEEP of 20HZ. The assessment of pain and functionality was performed using the data collection instrument, the Visual Analogue Pain Scale (VAS), Rolland Morris Disability Questionnaire (RMDQ) and the Owestry Disability Questionnaire (ODQ) respectively. Data analysis was performed using the JAMOVI 2.2.5 software. Our data showed that individuals with interferential current showed significant improvement in pain relief, as well as in the functional pattern of pain improvement. The present study demonstrates that treatment with interferential current promotes chemical improvement in participants, which opens up new perspectives on the use of this therapeutic approach.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Intervenction | Experimental | We used the SONOPULSE II device from the manufacturer IBRAMED, the electrodes measuring nine centimeters in length and five centimeters in width, from the manufacturer ARKTUS, of the adhesive plate type. According to the IBRAMED manual (2011, p. 47), the application is produced by two medium frequency currents through four electrodes, quadripolar method. The current type is tetrapolar interferential and the stimulation mode is automatic vector; the carrier frequency of 4000HZ, AMF modulation frequency of 50HZ, and the sweep frequency of SWEEP will be 20HZ. SWEEP sweep modes with 6 seconds of rise from the modulation frequency to the threshold the sweep frequency upon reaching the threshold immediately decays over the next 6 seconds. The positioning of the four-leaf clover type electrodes and the intensity of the strong current, however comfortable, according to the patient's report. |
|
| Control Group 01 | Active Comparator | he treatment is based on non-invasive methods, highlighting manual therapy techniques, especially joint manipulation therapy. Manual therapy techniques are adjustments in lumbar rotation. Joint adjustment is a controlled lever-like force with direction, amplitude, and speed that is applied to specific, tissue-adjacent joints. While joint mobilization is manual therapy without the impulse, the joint remains within the physiological range of motion (SILVA et al., 2012). Therefore, a high-velocity, low-amplitude (HVA) manual maneuver was applied. The thrust (impulse) is carried out in the para-physiological environment, between the physiological and anatomical barriers. preload phase before the manipulation, thrust phase where the maneuver is performed with high speed and low amplitude and the resolution phase where the manipulation ends. The maneuver is detailed by the authors Bergmann & Peterson (2010). |
|
| Control Group 02 | Active Comparator |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| physiotherapy treatment | Other | this is an interventional study of the use of 3 physiotherapy treatment techniques in order to evaluate the effectiveness of interferential current in relieving chronic low back pain |
| Measure | Description | Time Frame |
|---|---|---|
| Isolated comparative evaluation method, before and after, in the three arms with Application of Rolland Morris Questionnaires | Application of Rolland Morris Questionnaires before and after intervention, this questionnaires assesses mild and moderate pain and disability | 12 months |
| Isolated comparative evaluation method, before and after, in the three arms, Application of Owestry Questionnaire | Application of Owestry Questionnaire before and after intervention, this questionnaires evaluates more severe disabilities | 12 months |
| Isolated comparative evaluation method, before and after, in the three arms, Application analogue visual score for pain | Application analogue visual score for pain before and after intervention, evaluates the level of pain according to the patient's reference | 12 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Luiz Paulo Sobral Pereia | Santarém | Pará | 680005150 | Brazil |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D009784 | Occupational Diseases |
Not provided
Not provided
Not provided
The research is a randomized clinical trial, was submitted and approved by the Human Ethics Committee (CEP) with opinion 5,175,882, CAEE: 52035721.9.0000.0171. Participants were chosen at random, with single-blind masking, Random Allocation ® software was used to generate random numbers for the intervention and control groups, non-probalistic convenience sample. There were three groups: interventional, control 01 and control 02
Not provided
Not provided
only the participant was blinded
The procedure adopted in this group was based on the guidelines and recommendations for non-pharmacological treatment of the Associação Médica Brasileira AMB (RACHED, R.D.V.A. et al, 2013) use of 1 MHZ Ultrasound with a power of 1W/cm2, continuous IBRAMED device for 10 minutes, Wave Diathermy Short for 15 minutes/day, HTM brand, TENS 50 HZ and 50 ms intensity phase according to the patient's threshold, 30 minutes, IBRAMED brand |
|