Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The aim of this study was to describe a novel digital technique to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist. Materials and methods: Ten patients were consecutively included to rehabilitate partial edentulism by dental implants. Both the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were submitted to a digital impression through an intraoral scan to generate a Standard Tessellation Language digital file preoperatively (STL1), at 3 months (STL2), and 6 months (STL3) follow-up. Afterwards, an alignment procedure of the digital files (STL1-STL3) was performed on a reverse engineering morphometric software and volume changes at the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were analyzed using Student's t-test. Moreover, Gage R&R statistical analysis was conducted to analyze the repeatability and reproducibility of the digital technique.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients thats were chosen in order to rehabilitate partial edentulism by dental implants. | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| The wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth | Procedure | A novel digital technique to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist |
| Measure | Description | Time Frame |
|---|---|---|
| Wear volume (µm3) of the screw-retained implant-supported metal-ceramic dental prostheses | Wear volume (µm3) of the screw-retained implant-supported metal-ceramic dental prostheses at 3 months follow-up appointment | 3 months follow-up appointment |
| Wear volume (µm3) of the screw-retained implant-supported metal-ceramic dental prostheses | Wear volume (µm3) of the screw-retained implant-supported metal-ceramic dental prostheses at 6 months follow-up appointment | 6 months follow-up appointment |
| Wear volume (µm3) of the natural tooth as antagonist | Wear volume (µm3) of the natural tooth as antagonist at 3 months follow-up appointment | 3 months follow-up appointment |
| Wear volume (µm3) of the natural tooth as antagonist | Wear volume (µm3) of the natural tooth as antagonist at 6 months follow-up appointment | 6 months follow-up appointment |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Salamanca | Salamanca | 37008 | Spain |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31655831 | Result | Castellanos-Cosano L, Rodriguez-Perez A, Spinato S, Wainwright M, Machuca-Portillo G, Serrera-Figallo MA, Torres-Lagares D. Descriptive retrospective study analyzing relevant factors related to dental implant failure. Med Oral Patol Oral Cir Bucal. 2019 Nov 1;24(6):e726-e738. doi: 10.4317/medoral.23082. | |
| 2654359 | Result |
Not provided
Not provided
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Wiley MG. Effects of porcelain on occluding surfaces of restored teeth. J Prosthet Dent. 1989 Feb;61(2):133-7. doi: 10.1016/0022-3913(89)90360-0. |
| 8778391 | Result | Hudson JD, Goldstein GR, Georgescu M. Enamel wear caused by three different restorative materials. J Prosthet Dent. 1995 Dec;74(6):647-54. doi: 10.1016/s0022-3913(05)80319-1. |
| 6358468 | Result | Fisher RM, Moore BK, Swartz ML, Dykema RW. The effects of enamel wear on the metal-porcelain interface. J Prosthet Dent. 1983 Nov;50(5):627-31. doi: 10.1016/0022-3913(83)90198-1. |
| 1999562 | Result | Seghi RR, Rosenstiel SF, Bauer P. Abrasion of human enamel by different dental ceramics in vitro. J Dent Res. 1991 Mar;70(3):221-5. doi: 10.1177/00220345910700031301. |
| 12011863 | Result | Oh WS, Delong R, Anusavice KJ. Factors affecting enamel and ceramic wear: a literature review. J Prosthet Dent. 2002 Apr;87(4):451-9. doi: 10.1067/mpr.2002.123851. |
| 18482349 | Result | Ohlmann B, Trame JP, Dreyhaupt J, Gabbert O, Koob A, Rammelsberg P. Wear of posterior metal-free polymer crowns after 2 years. J Oral Rehabil. 2008 Oct;35(10):782-8. doi: 10.1111/j.1365-2842.2008.01865.x. Epub 2008 May 9. |
| 24136675 | Result | Hmaidouch R, Weigl P. Tooth wear against ceramic crowns in posterior region: a systematic literature review. Int J Oral Sci. 2013 Dec;5(4):183-90. doi: 10.1038/ijos.2013.73. Epub 2013 Oct 18. |
| 18548965 | Result | Etman MK, Woolford M, Dunne S. Quantitative measurement of tooth and ceramic wear: in vivo study. Int J Prosthodont. 2008 May-Jun;21(3):245-52. |
| 17692593 | Result | Yilmaz H, Aydin C, Gul BE. Flexural strength and fracture toughness of dental core ceramics. J Prosthet Dent. 2007 Aug;98(2):120-8. doi: 10.1016/S0022-3913(07)60045-6. |
| 23746749 | Result | Heintze SD, Zellweger G, Sbicego S, Rousson V, Munoz-Viveros C, Stober T. Wear of two denture teeth materials in vivo-2-year results. Dent Mater. 2013 Sep;29(9):e191-204. doi: 10.1016/j.dental.2013.04.012. Epub 2013 Jun 6. |
| 21384126 | Result | Stober T, Geiger A, Rues S, Dreyhaupt J, Rammelsberg P, Ohlmann B. Factors affecting wear of composite resin denture teeth--24-month results from a clinical study. Clin Oral Investig. 2012 Apr;16(2):413-20. doi: 10.1007/s00784-011-0534-y. Epub 2011 Mar 8. |
| 32290554 | Result | Zubizarreta-Macho A, Triduo M, Alonso Perez-Barquero J, Guinot Barona C, Albaladejo Martinez A. Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study. J Clin Med. 2020 Apr 12;9(4):1098. doi: 10.3390/jcm9041098. |