The new image reconstruction algorithm (Precise Image, Philips Healthcare) has a strong potential to maintain sufficient image quality suitable for diagnosis with ultra-low dose (ULD) chest and abdomen-pelvis scans.
The hypothesis is that the images obtained with the Precise Image algorithm for ULD acquisitions are of sufficient and suitable quality for the diagnosis of certain lung, abdominal-pelvic and bone lesions.
Recently a new image reconstruction algorithm based on Deep-learning has been developed (Precise Image, Philips Healthcare). Initial studies on phantoms have shown that this algorithm improves image quality and reduces patient dose compared to the iDose4 iterative reconstruction algorithm. Feasibility studies have validated the image quality for low-dose levels (LD). However, this algorithm has a strong potential to maintain sufficient image quality suitable for diagnosis with ultra-low dose (ULD) chest and abdomen-pelvis scans.
The hypothesis is that the images obtained with the Precise Image algorithm for ULD acquisitions are of sufficient and suitable quality for the diagnosis of certain lung, abdominal-pelvic and bone lesions.
The purpose of this study is to evaluate the concordance of the global quality of thoraco-abdominopelvic images of a ULD scan acquisition compared to a standard dose CT acquisition and measure the global agreement of the global quality of the images with a 4-point Likert scale.
The ULD acquisition will allow a significant reduction in the X-ray dose delivered to patients compared to a standard dose conventional scanner. This reduction is estimated at 70%.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients undergoing Ultra-Low-Dose scan plus conventional standard dose thoraco-abdominopelvic scan | Experimental | All adult patients (except pregnant women) presenting to the imaging department of the Institut de Cancérologie du Gard for a thoraco-abdominopelvic scan as part of an oncology follow-up will under a standard-dose can as well as an ultra-low-dose scan. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Ultra-Low-Dose thoraco-abdominopelvic scan | Radiation | In addition to the usual management (i.e. standard dose Computed Tomography), an Ultra-Low-Dose thoraco-abdominopelvic scan will be routinely performed. |
| Measure | Description | Time Frame |
|---|---|---|
| Concordance of the global quality of thoraco-abdomino-pelvic images from an Ultra-Low-Dose scanner acquisition compared to a standard dose scanner acquisition | A 4-point Likert scale will be used to evaluate the overall image quality to see whether it is good enough to visualize the structures of interest and possible lesions. Overall image quality is rated as follows:
| Day 0 |
| Measure | Description | Time Frame |
|---|---|---|
| Distribution of image quality with the standard dose scanner | Distribution of image quality for each of the two examinations of interest (ULD scanner and standard dose scanner) and to estimate the frequency of good quality images (level 1-2) for each of the two examinations.
|
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Julien FRANDON, Prof. | Nîmes University Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| CHU | Nîmes | 30029 | France |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Monocentric study of the subject as his/her own control
Not provided
Not provided
The reading of the images from the ULD scanner acquisition will be performed blinded to the patient's clinical record, the diagnosis made by the radiologist in charge of the patient on the basis of the standard dose conventional scanner, the result of the reading of the standard dose conventional scanner study and the reading of the other evaluator.
Not provided
| Day 0 |
| Frequency of good quality images with the standard dose scanner | Distribution of image quality for each of the two examinations of interest (ULD scanner and standard dose scanner) and to estimate the frequency of good quality images (level 1-2) for each of the two examinations. Grouping of the variable into 2 classes for the estimation of the frequency of good quality (1-2) images:- 1-2 vs. 3-4 | Day 0 |
| Distribution of image quality with the Ultra-Low-Dose scanner | Distribution of image quality for each of the two examinations of interest (ULD scanner and standard dose scanner) and to estimate the frequency of good quality images (level 1-2) for each of the two examinations.
| Day 0 |
| Frequency of good quality images with the Ultra-Low-Dose scanner | Distribution of image quality for each of the two examinations of interest (ULD scanner and standard dose scanner) and to estimate the frequency of good quality images (level 1-2) for each of the two examinations. Grouping of the variable into 2 classes for the estimation of the frequency of good quality (1-2) images:- 1-2 vs. 3-4 | Day 0 |
| Confidence level of each radiologist's diagnosis : Ultra-Low-Dose scan acquisition | To compare the confidence level of each radiologist's diagnosis for each of the two examinations of interest (Ultra-Low-Dose scan and standard dose scan) a subjective assessment of the each radiologist's (Junior/Senior) diagnostic confidence level will be made. | Day 0 |
| Confidence level of each radiologist's diagnosis : Standard-Dose scan acquisition | To compare the confidence level of each radiologist's diagnosis for each of the two examinations of interest (Ultra-Low-Dose scan and standard dose scan) a subjective assessment of the each radiologist's (Junior/Senior) diagnostic confidence level will be made. | Day 0 |
| Inter-rater agreement (Senior vs. junior radiologist) regarding the Ultra-Low-Dose scan acquisitions | Likert scales for global image quality and the level of confidence of the diagnosis will be used to assess inter-rater agreement (senior radiologist vs. junior radiologist) for each CT acquisition. | Day 0 |
| Inter-rater agreement (Senior vs. junior radiologist) regarding the Standard-Dose scan acquisitions | Likert scales for global image quality and the level of confidence of the diagnosis will be used to assess inter-rater agreement (senior radiologist vs. junior radiologist) for each CT acquisition. | Day 0 |
| Overall concordance of the diagnosis. Thoracic lesions seen on the Ultra-Low-Dose scan | Overall concordance of the diagnosis of thoracic, abdominal and/or pelvic lesions made from a ULD scan or from a conventional standard dose scan in these patients. Presence of at least one thoracic, (Yes/No) | Day 0 |
| Overall concordance of the diagnosis. Thoracic lesions seen on the Standard-Dose scan | Overall concordance of the diagnosis of thoracic, abdominal and/or pelvic lesions made from a ULD scan or from a conventional standard dose scan in these patients. Presence of at least one thoracic lesion (Yes/No) | Day 0 |
| Overall concordance of the diagnosis. Abdominal lesions seen on the Ultra-Low-Dose scan | Overall concordance of the diagnosis of thoracic, abdominal and/or pelvic lesions made from a ULD scan or from a conventional standard dose scan in these patients. Presence of at least one abdominal lesion (Yes/No) | Day 0 |
| Overall concordance of the diagnosis. Abdominal lesions seen on the Standard-Dose scan | Overall concordance of the diagnosis of thoracic, abdominal and/or pelvic lesions made from a ULD scan or from a conventional standard dose scan in these patients. Presence of at least one abdominal lesion (Yes/No) | Day 0 |
| Overall concordance of the diagnosis. Pelvic lesions seen on the Ultra-Low-Dose scan | Overall concordance of the diagnosis of thoracic, abdominal and/or pelvic lesions made from a ULD scan or from a conventional standard dose scan in these patients. Presence of at least one pelvic lesion (Yes/No) | Day 0 |
| Overall concordance of the diagnosis. Pelvic lesions seen on the Standard-Dose scan | Overall concordance of the diagnosis of thoracic, abdominal and/or pelvic lesions made from a ULD scan or from a conventional standard dose scan in these patients. Presence of at least one pelvic lesion (Yes/No) | Day 0 |
| Overall concordance of the diagnosis. Spine lesions seen on the Ultra-Low-Dose scan | Overall concordance of the diagnosis of bone lesions of the spine and pelvis made from a ULD scan or from a standard dose CT scan in these patients. Presence of at least one bone lesion within the spine (Yes/No). | Day 0 |
| Overall concordance of the diagnosis. Spine lesions seen on the Standard-Dose scan | Overall concordance of the diagnosis of bone lesions of the spine and pelvis made from a ULD scan or from a standard dose CT scan in these patients. Presence of at least one bone lesion within the spine (Yes/No). | Day 0 |
| Overall concordance of the diagnosis. Pelvic bone lesions seen on the Ultra-Low-Dose scan | Overall concordance of the diagnosis of bone lesions of the spine and pelvis made from a ULD scan or from a standard dose CT scan in these patients. Presence of at least one bone lesion on the pelvis (Yes/No). | Day 0 |
| Overall concordance of the diagnosis. Pelvic bone lesions seen on the Standard-Dose scan | Overall concordance of the diagnosis of bone lesions of the spine and pelvis made from a ULD scan or from a standard dose CT scan in these patients. Presence of at least one bone lesion on the pelvis (Yes/No). | Day 0 |
| ID | Term |
|---|---|
| D004194 | Disease |
| D008171 | Lung Diseases |
| D001847 | Bone Diseases |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D012140 | Respiratory Tract Diseases |
| D009140 | Musculoskeletal Diseases |
Not provided
Not provided