Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Magnamed Tecnologia Medica S/A | UNKNOWN |
Not provided
Not provided
Not provided
The goal of this diagnostic study is to validate estimation of inspiratory muscle pressure by an artificial intelligence algorithm compared to the gold standard, the measure from an esophageal catheter balloon, in patients under assisted mechanical ventilation. The main questions it aims to answer are:
• Are inspiratory muscle pressure estimates from an artificial intelligence algorithm accurate when compared to the direct measure from an esophageal balloon?
Participants will be monitored with an esophageal balloon and with an artificial intelligence algorithm simultaneously, with inspiratory muscle pressure estimation during assisted mechanical ventilation with decremental levels of pressure support.
This is a diagnostic study to validate estimation of inspiratory muscle pressure during assisted ventilation from an artificial intelligence algorithm integrated in a mechanical ventilator (FlexiMag, Magnamed, Brazil) compared to direct measure of muscle pressure from esophageal catheter balloon (gold standard). This is a novel non-invasive method to estimate inspiratory muscle pressure.
After obtaining informed consent, participants will be monitored simultaneously with the esophageal balloon and the artificial intelligence algorithm, with decremental levels of pressure support (20 to 2 cmH2O, in steps of 20 minutes). Esophageal balloon will be removed after completing the last pressure support step.
The investigators estimated a sample of 50 participants, considering 3 cmH2O as a clinically relevant discordance between methods and 10% of missing data. Concordance analysis and correlation analysis will be performed.
Procedures will follow a specific Standard Operating Procedures and participants inclusion data will be inserted in REDCap.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Artificial Intelligence Estimation of Muscle Pressure during Mechanical Ventilation | Other | All included subjects will be monitored simultaneously with the esophageal balloon (gold standard) and with the artificial intelligence algorithm integrated in the mechanical ventilator. Electrical Impedance Tomography will be used to monitor ventilatory patterns during different degrees of spontaneous effort. First, a single intravenous bolus of neuromuscular blockade (succinylcholine 1mg/kg or rocuronium 1.2mg/kg) will be performed to measure respiratory system mechanics (compliance and resistance). In cases where rocuronium is used, a single dose of sugammadex 4mg/kg will be administered intravenously to reverse neuromuscular blockade after measuring compliance and resistance. After initiation of spontaneous breathing effort, pressure support will be titrated from 20 cmH2O to 2 cmH2O, in decremental steps during 20 minutes each. After completing titrating of pressure support, the esophageal balloon will be removed. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Artificial Intelligence Estimation of Muscle Pressure during Mechanical Ventilation | Device | Estimation of inspiratory muscle pressure by an artificial intelligence algorithm integrated in the mechanical ventilator (FlexiMag, Magnamed, Brazil). |
| Measure | Description | Time Frame |
|---|---|---|
| Concordance between muscle pressure amplitude (in cmH2O) estimation by artificial intelligence and esophageal balloon | Analysis of the bias and limits of agreement (Bland-Altman plot) between muscle pressure estimated amplitude in cmH2O from artificial intelligence and measured by esophageal balloon. | 4 hours |
| Correlation between muscle pressure amplitude estimation (in cmH2O) by artificial intelligence and esophageal balloon | Correlation, reported as R-squared and a correlation plot, between amplitude in cmH2O of muscle pressure estimation by artificial intelligence and esophageal balloon. | 4 hours |
| Detection of initiation time and ending time of a spontaneous breathing cycle by artificial intelligence compared with esophageal balloon | Time difference (in ms) between initiation of a spontaneous breathing cycle and ending of a spontaneous breathing cycle between artificial intelligence and esophageal balloon. | 4 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Sensitivity and specificity of patient-ventilator asynchrony automated detection using the Artificial Intelligence Muscle Pressure estimator | Number of patient-ventilator asynchronies detected using artificial intelligence compared with number of asynchronies detected by experts assessing airway pressure, flow and esophageal balloon waveforms. | 4 hours |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Eduardo LV Costa, MD, PhD | University of Sao Paulo | Principal Investigator |
| Marcelo BP Amato, MD, PhD | University of Sao Paulo | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Heart Institute, University of São Paulo | São Paulo | São Paulo | 05403900 | Brazil |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 9449727 | Background | Amato MB, Barbas CS, Medeiros DM, Magaldi RB, Schettino GP, Lorenzi-Filho G, Kairalla RA, Deheinzelin D, Munoz C, Oliveira R, Takagaki TY, Carvalho CR. Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome. N Engl J Med. 1998 Feb 5;338(6):347-54. doi: 10.1056/NEJM199802053380602. | |
| 10793162 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D012131 | Respiratory Insufficiency |
| ID | Term |
|---|---|
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Acute Respiratory Distress Syndrome Network; Brower RG, Matthay MA, Morris A, Schoenfeld D, Thompson BT, Wheeler A. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000 May 4;342(18):1301-8. doi: 10.1056/NEJM200005043421801. |
| 25693019 | Background | Loring SH, Malhotra A. Driving pressure and respiratory mechanics in ARDS. N Engl J Med. 2015 Feb 19;372(8):776-7. doi: 10.1056/NEJMe1414218. No abstract available. |
| 24199628 | Background | Yoshida T, Torsani V, Gomes S, De Santis RR, Beraldo MA, Costa EL, Tucci MR, Zin WA, Kavanagh BP, Amato MB. Spontaneous effort causes occult pendelluft during mechanical ventilation. Am J Respir Crit Care Med. 2013 Dec 15;188(12):1420-7. doi: 10.1164/rccm.201303-0539OC. |
| 27002273 | Background | Yoshida T, Roldan R, Beraldo MA, Torsani V, Gomes S, De Santis RR, Costa EL, Tucci MR, Lima RG, Kavanagh BP, Amato MB. Spontaneous Effort During Mechanical Ventilation: Maximal Injury With Less Positive End-Expiratory Pressure. Crit Care Med. 2016 Aug;44(8):e678-88. doi: 10.1097/CCM.0000000000001649. |
| 29323931 | Background | Yoshida T, Amato MBP, Grieco DL, Chen L, Lima CAS, Roldan R, Morais CCA, Gomes S, Costa ELV, Cardoso PFG, Charbonney E, Richard JM, Brochard L, Kavanagh BP. Esophageal Manometry and Regional Transpulmonary Pressure in Lung Injury. Am J Respir Crit Care Med. 2018 Apr 15;197(8):1018-1026. doi: 10.1164/rccm.201709-1806OC. |
| 29323536 | Background | Morais CCA, Koyama Y, Yoshida T, Plens GM, Gomes S, Lima CAS, Ramos OPS, Pereira SM, Kawaguchi N, Yamamoto H, Uchiyama A, Borges JB, Vidal Melo MF, Tucci MR, Amato MBP, Kavanagh BP, Costa ELV, Fujino Y. High Positive End-Expiratory Pressure Renders Spontaneous Effort Noninjurious. Am J Respir Crit Care Med. 2018 May 15;197(10):1285-1296. doi: 10.1164/rccm.201706-1244OC. |
| 33883458 | Background | Sousa MLEA, Magrans R, Hayashi FK, Blanch L, Kacmarek RM, Ferreira JC. Clusters of Double Triggering Impact Clinical Outcomes: Insights From the EPIdemiology of Patient-Ventilator aSYNChrony (EPISYNC) Cohort Study. Crit Care Med. 2021 Sep 1;49(9):1460-1469. doi: 10.1097/CCM.0000000000005029. |
| 32032901 | Background | Sousa MLA, Magrans R, Hayashi FK, Blanch L, Kacmarek RM, Ferreira JC. Predictors of asynchronies during assisted ventilation and its impact on clinical outcomes: The EPISYNC cohort study. J Crit Care. 2020 Jun;57:30-35. doi: 10.1016/j.jcrc.2020.01.023. Epub 2020 Jan 21. |
| 25693449 | Background | Blanch L, Villagra A, Sales B, Montanya J, Lucangelo U, Lujan M, Garcia-Esquirol O, Chacon E, Estruga A, Oliva JC, Hernandez-Abadia A, Albaiceta GM, Fernandez-Mondejar E, Fernandez R, Lopez-Aguilar J, Villar J, Murias G, Kacmarek RM. Asynchronies during mechanical ventilation are associated with mortality. Intensive Care Med. 2015 Apr;41(4):633-41. doi: 10.1007/s00134-015-3692-6. Epub 2015 Feb 19. |
| 26017442 | Background | LeCun Y, Bengio Y, Hinton G. Deep learning. Nature. 2015 May 28;521(7553):436-44. doi: 10.1038/nature14539. |
| 29189344 | Background | Pletsch-Assuncao R, Caleffi Pereira M, Ferreira JG, Cardenas LZ, de Albuquerque ALP, de Carvalho CRR, Caruso P. Accuracy of Invasive and Noninvasive Parameters for Diagnosing Ventilatory Overassistance During Pressure Support Ventilation. Crit Care Med. 2018 Mar;46(3):411-417. doi: 10.1097/CCM.0000000000002871. |
| 7149443 | Background | Baydur A, Behrakis PK, Zin WA, Jaeger M, Milic-Emili J. A simple method for assessing the validity of the esophageal balloon technique. Am Rev Respir Dis. 1982 Nov;126(5):788-91. doi: 10.1164/arrd.1982.126.5.788. |
| 19507134 | Background | Liao JJ. Sample size calculation for an agreement study. Pharm Stat. 2010 Apr-Jun;9(2):125-32. doi: 10.1002/pst.382. |
| 33439952 | Background | Motta APG, Rigobello MCG, Silveira RCCP, Gimenes FRE. Nasogastric/nasoenteric tube-related adverse events: an integrative review. Rev Lat Am Enfermagem. 2021 Jan 8;29:e3400. doi: 10.1590/1518-8345.3355.3400. eCollection 2021. |