This is a prospective, multicentric study that aim to assess stability of a tapered porous coated stem and a cementless hemispherical acetabular component.
Main Translation and rotation around the x., y-, and z-axis of the femoral and cup component by radiostereometric analysis (RSA) at immediate post op (within 5 days and before weight bearing), 6 months, 1year and 2 years
Aim of this study is to assess stem and cup migration over the time in patient subjected to a total hip arthroplasty. Medical Device Research Australia will perform image analysis services and reporting for model based radiostereometric analysis (RSA) of cementless fixation of the femoral and acetabular cup components. Migration of the components will be measured with model-based RSA (MBRSA) at immediate post op (within 5 days and before weight bearing), 6 months, 1year and 2 years A subgroup of 26 patients will be invited to be evaluated also by additional RSA analysis: the first 13 patients for each investigator who will accept.
The results of this work will establish the mechanical stability of Masterloc femoral component (Medacta International SA) and MPACT acetabular component (Medacta International SA), provide a general estimate of survivorship, and establish clinical safety and efficacy as measured by RSA and clinical outcomes.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| RSA imaging | All RSA analysis will be performed Computer Aided Design (CAD) based Roentgen Stereophotogrammetry Analysis (RSA). The micro-motion results will be calculated and reported as translations and rotations along and about the three anatomic axes. The subsidence of the hip stem is included in the results. The motion of the femoral stem and acetabular cup will be described in relation to the marker beads placed in the proximal femur and acetabular bone during surgery respectively. The first CAD based RSA examination (within 5 days and prior to weight bearing) serves as the reference baseline. All subsequent evaluations of micromotion are related to the relative position of the implanted medical device with respect to the bone (bone markers) at the time of the evaluation | 2 years |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
26 patients who entirely fulfil the inclusion/exclusion criteria. The patients will be recruited in a period of 12 months.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael Dixon, Medicine | Southerland Public Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Southerland Public Hospital | Sydney | Australia |
Not provided