Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Tung Wah College | OTHER |
Not provided
Not provided
Not provided
Not provided
Background: In emergency departments, suturing is a common procedure but often causes anxiety and pain. Virtual reality (VR) intervention has been reported as a relaxing measure.
Objective: The study aims to examine the effects of VR intervention on anxiety, pain, physiological parameters, local anaesthesia requirements and satisfaction in Chinese adult patients undergoing wound closure in emergency departments in Hong Kong
Hypothesis:VR can alleviate anxiety and pain experienced by Chinese adult patients undergoing wound-closure procedures, the intervention can decrease extra local anesthesia requirements and physiological parameters during the procedures, and the intervention can significantly increase satisfaction during wound-closure procedures.
Suturing is one of the most common procedure in the emergency department, however, it often provokes anxiety and pain. 1-2 Failure to manage patients' anxiety and pain during wound closure can cause difficulties for health care providers to complete the procedures and reduce the success rates. 3 Experience of anxiety and pain may also increase the need for medication, reduce patients' satisfaction rate and cause negative physiological parameters such as increased blood pressure and heart rate. 4-5.
Traditionally, nonpharmacological intervention such as listening to music, chatting, and guided imagery is applied to reduce patient's anxiety and pain. However these measures fail to provide patients with significant distraction because patients would inevitably see the procedure that causes considerable distress during the procedure. Thus, the development of further strategies to provide a significant distraction to alleviate patients' anxiety and pain during suturing is warranted.
With advanced technologies, virtual reality (VR) provides significant distraction. Clinical trials indicate that use of VR achieved a statistically significant decrease in anxiety and pain in different operations such as hand 6, lipoma incision 7, Gynecology 8, and debridement 9. However, only a handful of studies conducted among adult patient with ambulatory laceration repairing examined the effectiveness of VR in anxiety and pain. To the best of our knowledge, no study specifically focus on the effects of VR on anxiety and pain in Chinese adult patients undergoing an awake suture in emergency room in Hong Kong. Eighty participants will be assigned to the experimental group or to the control group by randomization.
After written informed consent will be obtained from patients, the baseline data (T0) will be obtained from the participants including sociodemographic, anxiety, blood pressure, and pulse rate. Subsequently, randomization is conducted. Throughout the procedure (T1), the additional medication requirements and physiological parameters will be recorded. The anxiety, pain and satisfaction and physiological parameters will also be recorded after the procedure. Data will be analyzed using IBM SPSS 23.0. Descriptive statistics, including frequency, percentage, mean and standard deviation will be used to describe the data. Chi-square tests compare categorical variables, and independent t-tests compare continuous variables. Generalized Estimation Equation will be used to examine the effectiveness of the VR intervention versus the control group will be evaluated by comparing the study outcomes. Two-tailed tests will be used with a significant level of 0.05.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Control group | Other | Participants in the control group will be received standard care |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Virtual reality | Device | Participants in the intervention group will be received VR during the suturing procedure. Virtual reality is a three dimensions of width, height and depth that is generated digitally in a computer-generated environment that allows a user to interact with it 16. |
| Measure | Description | Time Frame |
|---|---|---|
| Anxiety | The Chinese version of the State Trait Anxiety scale is used to measure anxiety levels of the patients. It contains two separate scales for state and trait anxiety. The first part (state anxiety) evaluates a transitory emotional state that is influenced by intense emotional situations and varies in intensity over time. The second part (trait anxiety) demonstrates a relatively stable anxious tendency and is not significantly influenced by emotionally intense situations. Each item is rated on a 4-point Likert scale, with total scores from 20 to 80. The high the score indicates the high a higher level of anxiety. The STAI-C is validated in Hong Kong and is found to have a high degree of internal consistency (Alpha = 0.9). Participants will be required to complete the state form at 5 minutes after the completion of the procedure in this study 10-12 | Baseline, and 5 minutes after the completion of the procedure |
| Measure | Description | Time Frame |
|---|---|---|
| Pain Level | Pain is measured by visual analogue scales (VAS). VAS is a commonly used method for quantifying pain. The scale comprises a 10cm line with terms representing the extremes of pain at either end. The patient estimates pain by placing a mark on the line. The distance from the zero point is then measured. The VAS has been shown to be a valid tool for the measurement of psychological and health variables such as pain and satisfaction which had been used in clinical studies widely 13-15. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| KO SHUK YEE, DN | Tuen Mun Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Tuen Mun Hospital-Emergency department | Hong Kong | Hong Kong |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30422942 | Background | Bryl AW, Bonsu B, Johnson AL, Pommert KBJ, Hollenbach KA, Kanegaye JT. Tablet Computer as a Distraction Tool During Facial Laceration Repair: A Randomized Trial. Pediatr Emerg Care. 2021 Aug 1;37(8):e425-e430. doi: 10.1097/PEC.0000000000001626. | |
| 11739597 | Background | Ploghaus A, Narain C, Beckmann CF, Clare S, Bantick S, Wise R, Matthews PM, Rawlins JN, Tracey I. Exacerbation of pain by anxiety is associated with activity in a hippocampal network. J Neurosci. 2001 Dec 15;21(24):9896-903. doi: 10.1523/JNEUROSCI.21-24-09896.2001. |
Not provided
Not provided
It is only a pilot study and will be modified after the pilot study. We will share it later on in the main study
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001008 | Anxiety Disorders |
| D010146 | Pain |
| ID | Term |
|---|---|
| D001523 | Mental Disorders |
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Intervention and control group
Not provided
Not provided
Investigator will not be involved the recruitment and data collection. Outcome assessor will be masked
Not provided
|
| During the procedure |
| Satisfaction level | Satisfaction is measured by visual analogue scales (VAS). VAS is a commonly used method for quantifying pain. The scale comprises a 10cm line with terms representing the extremes of pain at either end. The patient estimates satisfaction by placing a mark on the line. The distance from the zero point is then measured. The VAS has been shown to be a valid tool for the measurement of psychological and health variables such as pain and satisfaction which had been used in clinical studies widely 13-15. | 5 minutes after the completion of the procedure |
| Blood pressure | A standard blood pressure monitor is used to measure patients' blood pressure. The blood pressure is recorded as mmHg | Baseline, during and 5 minutes after the completion of the procedure |
| Pulse rate | A standard pulse oximetry is used to measure patients' pulse rate. The pulse rate is recorded as beat per minute (bpm) | Baseline, during and 5 minutes after the completion of the procedure |
| Additional local analgesic requirements | The frequency of extra local analgesic use (1 % Lidocaine) is recorded | During the procedure |
| 27864995 | Background | Parker SIA, Benzies KM, Hayden KA. A systematic review: effectiveness of pediatric peripheral intravenous catheterization strategies. J Adv Nurs. 2017 Jul;73(7):1570-1582. doi: 10.1111/jan.13211. Epub 2016 Dec 14. |
| 25463769 | Background | De Oliveira GS Jr, Holl JL, McCarthy RJ, Butt ZA, Nouriel J, McCaffery K, Wolf MS. Overestimation of mortality risk and preoperative anxiety in patients undergoing elective general surgery procedures: a propensity matched analysis. Int J Surg. 2014 Dec;12(12):1473-7. doi: 10.1016/j.ijsu.2014.11.016. Epub 2014 Nov 18. |
| 25493674 | Background | Robleda G, Sillero-Sillero A, Puig T, Gich I, Banos JE. Influence of preoperative emotional state on postoperative pain following orthopedic and trauma surgery. Rev Lat Am Enfermagem. 2014 Oct;22(5):785-91. doi: 10.1590/0104-1169.0118.2481. |
| 31348351 | Background | Hoxhallari E, Behr IJ, Bradshaw JS, Morkos MS, Haan PS, Schaefer MC, Clarkson JHW. Virtual Reality Improves the Patient Experience during Wide-Awake Local Anesthesia No Tourniquet Hand Surgery: A Single-Blind, Randomized, Prospective Study. Plast Reconstr Surg. 2019 Aug;144(2):408-414. doi: 10.1097/PRS.0000000000005831. |
| 30256662 | Background | Mosso Vazquez JL, Mosso Lara D, Mosso Lara JL, Miller I, Wiederhold MD, Wiederhold BK. Pain Distraction During Ambulatory Surgery: Virtual Reality and Mobile Devices. Cyberpsychol Behav Soc Netw. 2019 Jan;22(1):15-21. doi: 10.1089/cyber.2017.0714. Epub 2018 Sep 25. |
| Background | Mosso Vázquez JL, Lara Vaca V, Wiederhold BK, Miller IT, Wiederhold MD. Virtual reality pain distraction during gynecological surgery - a report of 44 cases. Surgical Research Updates. 2017;5(1):12-16. doi: 10.12970/2311-9888.2017.05. |
| 18427228 | Background | Hoffman HG, Patterson DR, Seibel E, Soltani M, Jewett-Leahy L, Sharar SR. Virtual reality pain control during burn wound debridement in the hydrotank. Clin J Pain. 2008 May;24(4):299-304. doi: 10.1097/AJP.0b013e318164d2cc. |
| Background | Spielberger CD, Gorsuch RC, Lushene RF. Manual of the State Trait Anxiety Inventory. Palo Alto, CA: Consulting psychologists Press; 1970 |
| Background | Shek DTL. The factorial structure of the Chinese version of the state-trait anxiety inventory: a confirmatory factor analysis. Psychol Edu Meas. 1991;51(4):985-997. doi:10.1177/001316449105100418 |
| 8315037 | Background | Shek DT. The Chinese version of the State-Trait Anxiety Inventory: its relationship to different measures of psychological well-being. J Clin Psychol. 1993 May;49(3):349-58. doi: 10.1002/1097-4679(199305)49:33.0.co;2-j. |
| 4139420 | Background | Huskisson EC. Measurement of pain. Lancet. 1974 Nov 9;2(7889):1127-31. doi: 10.1016/s0140-6736(74)90884-8. No abstract available. |
| 24921952 | Background | Kersten P, White PJ, Tennant A. Is the pain visual analogue scale linear and responsive to change? An exploration using Rasch analysis. PLoS One. 2014 Jun 12;9(6):e99485. doi: 10.1371/journal.pone.0099485. eCollection 2014. |
| 11748392 | Background | Bodian CA, Freedman G, Hossain S, Eisenkraft JB, Beilin Y. The visual analog scale for pain: clinical significance in postoperative patients. Anesthesiology. 2001 Dec;95(6):1356-61. doi: 10.1097/00000542-200112000-00013. |
| Background | Moskaliuk J, Kimmerle J, Cress U. Virtual reality 2.0 and its application in knowledge building. In handbook of research on web 2.0, 3.0, and X. O: technologies, business and social applications. USA: IGI Global, 2010. |