The goal of this multi-center clinical trial is to evaluate the efficacy and safety of the interventional robotic system for cerebral angiography, researchers will compare the ordinary angiography to assess the clinical success rate, operation time, radiation absorption, etc.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Interventional Robotic System Assisted Surgery | Experimental | Experimental group underwent cerebral angiography using the vascular interventional surgical control system |
|
| Traditional Manual Surgery | No Intervention | The control group process the traditional manual operation for cerebral angiography |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Interventional Robotic System | Device | Cerebral angiography was performed by using the interventional robotic system |
|
| Measure | Description | Time Frame |
|---|---|---|
| Clinical Success Rate | Assessment of the clinical success rate of the surgical physician in completing cerebral angiography examination through the operation of experimental instruments or artificial means. | at the end of surgery |
| Measure | Description | Time Frame |
|---|---|---|
| Super-selective Technique Success Rate | Assessing the technical success rate of the surgical physician in performing super-selective catheterization of cerebral vessels through the operation of experimental instruments or artificial means. | at the end of surgery |
| Super-selective Catheterization Time for Target Vessels |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Changhai Hospital | Recruiting | Shanghai | Shanghai City | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 40633938 | Derived | Zhang Y, Xu H, Sun J, Chen WH, Zhang Y, Chen M, Yi T, Wu YM, Cheng G, Guo J, Yang P, Guo S, Liu J. Safety and efficacy of cerebral robot assisted angiography: randomized comparison of robotic versus manual procedures. J Neurointerv Surg. 2026 Apr 16;18(5):1330-1336. doi: 10.1136/jnis-2025-023412. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Calculate and compare the average time taken to perform super-selective catheterization for each target vessel during each surgical procedure. |
| at the end of surgery |
| DSA Fluoroscopy Time | Record and compare the duration of fluoroscopy during DSA for each surgical procedure. | at the end of surgery |
| Surgical Time | Record and compare the duration of each surgical procedure. | at the end of surgery |
| Primary Operator Radiation Absorbed Dose | Record and compare the absorbed dose of ionizing radiation received by the primary operator during each surgical procedure. | at the end of surgery |
| Instrument Performance Evaluation | The surgical physician fills out a form after the surgery to subjectively evaluate the performance of the experimental instruments during the angiographic examination procedure. | at the end of surgery |