The aim of cavotricuspid isthmus (CTI) dependent flutter ablation is the bidirectional conduction block of CTI. The probability of achieving a permanent bidirectional block at the CTI depends, mainly, on the ablation energy applied and the quality of the obtained lesion. Among the factors that determine the lesion's quality those which have the bigger impact are catheter stability, contact force, power and duration of energy application and the temperature reached at depth.This is a multicenter 1:1 randomized, blinded (open for the operator) study. Two CTI ablation strategies are compared: 1) conventional treatment branch which consists of individual 25-40 W applications of unlimited duration until achieving in each application the minimum value of one of the currently accepted and used lesion markers (Ablation Index >500 at the anterior half of the CTI and >400 at the posterior half with de CARTO 3 system; 2) experimental treatment branch consistent of CTI block using individual high power (90W) short duration (4 seconds) point-by-point applications. The main objective of this study is assessing the non-inferiority of the efficacy and safety of high-power short-duration ablation in patients undergoing typical atrial flutter ablation. Secondary objectives include the comparison of total radiofrequency time, number of applications, number of steam pops, percentage of reconnections, procedure duration, pain during the procedure and time to atrial flutter recurrence.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Conventional ablation | Active Comparator | CTI ablation with electroanatomic navigation system using individual 25-40 W applications of unlimited duration until achieving in each application the minimum value of one of the currently accepted and used lesion markers: Ablation Index >500 at the anterior half of the CTI and >400 at the posterior half with de CARTO 3 system. Minimum contact force required is 5 grams. Maximum distance between applications must be 6 mm. |
|
| High-power short-duration ablation | Experimental | CTI ablation with electroanatomic navigation system using individual high power (90W) short duration (4 seconds) applications in a catheters' stable position with a minimum contact force of 15-30 g at the anterior half and 10-25 g at the posterior one. Maximum distance between applications is settled at 4 mm. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Conventional cavotricuspid isthmus ablation | Procedure | Point-by-point 25-40 W applications at the CTI of unlimited duration until achieving the pre-established Ablation Index. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Safety primary outcome: incidence of procedure-related complications. | Number of procedure-related complications from the time of the ablation until the last follow-up visit. | One year |
| Efficacy primary outcome: typical atrial flutter recurrence. | Incidence of typical atrial flutter recurrence during a one-year follow-up period. To be considered clinically relevant the recurrence must be documented by a full EKG made because of patients' symptoms or any typical atrial flutter detected by an EKG, 24h Holter-EKG or events-monitoring device that will be performed at least at a 6 months and 12 months follow-up visits. | One year |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Laura Valverde Soria | Contact | 687198597 | lauravalverdesoria@gmail.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital General Doctor Balmis Alicante | Recruiting | Alicante | A | 03010 | Spain |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 39708245 | Derived | Valverde Soria L, Toquero J, Brouzet T, Garcia Cano L, Garcia Barrios A, Segura Dominguez M, Hermon Ramirez GA, Ajo Ferrer R, Ajo Ferrer M, Andreu Concha CM, Arrarte Esteban V, Sanchez Barbie A, Martinez-Martinez JG, Ibanez Criado A, Ibanez Criado JL. Very high-power short-duration radiofrequency ablation in patients with typical atrial flutter: rationale and design of the FASD-HP randomized trial. J Interv Card Electrophysiol. 2025 Apr;68(3):497-503. doi: 10.1007/s10840-024-01969-7. Epub 2024 Dec 21. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| High-power short-duration ablation | Procedure | Point-by-point 90W applications at the CTI ablation during 4 seconds. |
|