This is a pilot study using a novel, minimal risk, portable, hands-free oral-positive pressure device (oPEP) in patients with Fontan palliation that will examine whether using this device in both the acute and chronic phase will alter Fontan hemodynamics and create pulsatility in the Fontan circuit and thereby increasing cardiac output. This device is easy to use and poses no significant risk to human subjects. The investigators will measure this through echocardiographic measures including pulsatility in different aspects of the Fontan circuit including IVC, hepatic veins, the Fontan conduit, and pulmonary arteries and aortic blood flow measurements. After demonstration of how to use the device appropriately, the investigators will have patients use the device after their clinical echocardiogram for their clinic appointment. The investigators will ask them to use the device at home 3-4 times a day for 10-15 mins and have them return in approximately 4 weeks to have another echocardiogram done with the same measurements.
The aortic VTI secondary outcome was inadvertently left out of the initial registration and is now reported
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Hands-free oral-positive pressure device (oPEP) | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Hands-free oral-positive pressure device (oPEP) | Device | This is a pilot study using a novel, minimal risk, portable, hands-free oral-positive pressure device (oPEP) in patients with Fontan palliation that will examine whether using this device in both the acute and chronic phase will alter Fontan hemodynamics and create pulsatility in the Fontan circuit and thereby increasing cardiac output. This device is easy to use and poses no significant risk to human subjects. We will measure this through echocardiographic measures including pulsatility in different aspects of the Fontan circuit including IVC, hepatic veins, the Fontan conduit, and pulmonary arteries and aortic blood flow measurements. After demonstration of how to use the device appropriately, we will have patients use the device after their clinical echocardiogram for their clinic appointment. We will ask them to use the device at home 3-4 times a day for 10-15 mins and have them return in approximately 4 weeks to have another echocardiogram done with the same measurements. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Pulmonary Pulsatility Index | This will be measured by echocardiogram using Doppler evaluation of the pulmonary artery The Pulmonary Artery Pulsatility Index (PAPI) is calculated using Doppler-derived pulmonary artery velocities: PAPI= (Systolic Velocity - Diastolic Velocity) /Mean Velocity | The change is between enrollment echocardiogram and echocardiogram after 4 week use of the device |
| Measure | Description | Time Frame |
|---|---|---|
| Aortic Valve VTI | This was measured by echocardiography Aortic Valve Velocity Time Integral (VTI) Definition: Aortic VTI is a key echocardiographic measurement reflecting stroke distance and cardiac output. Measurement: Obtained using pulsed-wave Doppler at the left ventricular outflow tract (LVOT) just below the aortic valve. The VTI is measured by tracing the Doppler envelope of the LVOT flow during systole. Clinical Importance: Stroke Volume Calculation: Stroke Volume = LVOT VTI × LVOT Area |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| UPMC Children's Hospital Pittsburgh | Pittsburgh | Pennsylvania | 15235 | United States |
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Hands-free Oral-positive Pressure Device (oPEP) | Hands-free oral-positive pressure device (oPEP): This is a pilot study using a novel, minimal risk, portable, hands-free oral-positive pressure device (oPEP) in patients with Fontan palliation that will examine whether using this device in both the acute and chronic phase will alter Fontan hemodynamics and create pulsatility in the Fontan circuit and thereby increasing cardiac output. This device is easy to use and poses no significant risk to human subjects. We will measure this through echocardiographic measures including pulsatility in different aspects of the Fontan circuit including IVC, hepatic veins, the Fontan conduit, and pulmonary arteries and aortic blood flow measurements. After demonstration of how to use the device appropriately, we will have patients use the device after their clinical echocardiogram for their clinic appointment. We will ask them to use the device at home 3-4 times a day for 10-15 mins and have them return in approximately 4 weeks to have another echocardiogram done with the same measurements. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Hands-free Oral-positive Pressure Device (oPEP) | Hands-free oral-positive pressure device (oPEP): This is a pilot study using a novel, minimal risk, portable, hands-free oral-positive pressure device (oPEP) in patients with Fontan palliation that will examine whether using this device in both the acute and chronic phase will alter Fontan hemodynamics and create pulsatility in the Fontan circuit and thereby increasing cardiac output. This device is easy to use and poses no significant risk to human subjects. We will measure this through echocardiographic measures including pulsatility in different aspects of the Fontan circuit including IVC, hepatic veins, the Fontan conduit, and pulmonary arteries and aortic blood flow measurements. After demonstration of how to use the device appropriately, we will have patients use the device after their clinical echocardiogram for their clinic appointment. We will ask them to use the device at home 3-4 times a day for 10-15 mins and have them return in approximately 4 weeks to have another echocardiogram done with the same measurements. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Change in Pulmonary Pulsatility Index | This will be measured by echocardiogram using Doppler evaluation of the pulmonary artery The Pulmonary Artery Pulsatility Index (PAPI) is calculated using Doppler-derived pulmonary artery velocities: PAPI= (Systolic Velocity - Diastolic Velocity) /Mean Velocity | Posted | Mean | Standard Deviation | Ratio | The change is between enrollment echocardiogram and echocardiogram after 4 week use of the device |
|
4 weeks
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Hands-free Oral-positive Pressure Device (oPEP) | Hands-free oral-positive pressure device (oPEP): This is a pilot study using a novel, minimal risk, portable, hands-free oral-positive pressure device (oPEP) in patients with Fontan palliation that will examine whether using this device in both the acute and chronic phase will alter Fontan hemodynamics and create pulsatility in the Fontan circuit and thereby increasing cardiac output. This device is easy to use and poses no significant risk to human subjects. We will measure this through echocardiographic measures including pulsatility in different aspects of the Fontan circuit including IVC, hepatic veins, the Fontan conduit, and pulmonary arteries and aortic blood flow measurements. After demonstration of how to use the device appropriately, we will have patients use the device after their clinical echocardiogram for their clinic appointment. We will ask them to use the device at home 3-4 times a day for 10-15 mins and have them return in approximately 4 weeks to have another echocardiogram done with the same measurements. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Dr. Tarek Alsaied | Children's Hospital of Pittsburgh | 5136521226 | tarek.alsaied84@gmail.com |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Jan 1, 2024 | Jan 16, 2025 | Prot_SAP_001.pdf |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000080039 | Univentricular Heart |
| ID | Term |
|---|---|
| D006330 | Heart Defects, Congenital |
| D018376 | Cardiovascular Abnormalities |
| D002318 | Cardiovascular Diseases |
| D006331 | Heart Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Baseline, 4 weeks |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
|
|
|
| Secondary | Aortic Valve VTI | This was measured by echocardiography Aortic Valve Velocity Time Integral (VTI) Definition: Aortic VTI is a key echocardiographic measurement reflecting stroke distance and cardiac output. Measurement: Obtained using pulsed-wave Doppler at the left ventricular outflow tract (LVOT) just below the aortic valve. The VTI is measured by tracing the Doppler envelope of the LVOT flow during systole. Clinical Importance: Stroke Volume Calculation: Stroke Volume = LVOT VTI × LVOT Area | Posted | Mean | Standard Deviation | cm/sec | Baseline, 4 weeks |
|
|
|
|
| 0 |
| 15 |
| 0 |
| 15 |
| 0 |
| 15 |
Not provided
Not provided
| D000013 | Congenital Abnormalities |
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |