Compression wraps treat venous leg ulcers when applied correctly. Often, clinicians apply the wraps at the wrong compression, or the wrap loosens, stopping clinical benefits. The study aims to show the feasibility of a smart compression prototype to maintain a set compression level in healthy volunteers. Each volunteer will wear the prototype device on one leg and a standard compression wrap on the other. Volunteers will pump their calves, walk, lie down, and stand at zero, one, and four hours. A pressure sensor placed over each calf will record the compression level during the activities. Volunteers will provide subjective feedback on each device concerning comfort and usability. After four hours, researchers will remove the standard wrap. Volunteers will use the prototype device during daily activities for three days. During the three days, the volunteers will complete a daily journal. The journal will capture the user experience and time the volunteer used the device. A final site visit allows researchers to conduct exit interviews and download the history of applied compression. Researchers will use the data to show that the prototype device maintains therapeutic compression and prove the usability of the device.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Compression Therapy System Prototype | Experimental | Identifies legs randomized to receive the experimental intervention |
|
| Coban 2 (2 Layer Compression Wrap) | Active Comparator | Identifies the legs randomized to receive the control intervention |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Compression Therapy System Prototype | Device | A device designed to deliver compression therapy at a pre-set level to the lower leg for legs with a circumference between 30-50 cm. The device provides compression through a series of three air bladders and is controlled by a battery-powered electronic module that controls compression levels by monitoring bladder pressure. |
| Measure | Description | Time Frame |
|---|---|---|
| Time to Apply Intervention by clinician | The time it takes a clinician to place the assigned intervention to each limb | Measured on Day 0 |
| Time to Apply compression therapy prototype by volunteer | The time it takes the volunteer to place the assigned intervention to each limb | Measured on Day 0 |
| Interface Pressure after Application of Intervention | Interface pressure measured by pressure sensor (Pico Press) following application by research clinician | Measured on Day 1 |
| Average Interface Pressure during Walking | The participant walks on a treadmill for 10 minutes. A pressure sensor (Pico Press) continuously measures compression at the medial gastrocnemius head. The interface pressure measurements are averaged over ten minutes of data collection. The analysis compares changes in pressure over the three measurements for each intervention. | Measured at 0 hours, 1 hour, and 4 hours on Day 1 |
| Average Interface Pressure during Calf Pumping | The participant pumps each calf independently for 30 seconds. A pressure sensor (Pico Press) continuously measures compression at the medial gastrocnemius head. The interface pressure measurements are averaged over 30 seconds of data collection. The analysis compares changes in pressure over the three measurements for each intervention. | Measured at 0 hours, 1 hour, and 4 hours on Day 1 |
| Average Interface Pressure during Standing | The participant stands for 30 seconds. A pressure sensor (Pico Press) continuously measures compression at the medial gastrocnemius head. The interface pressure measurements are averaged over 30 seconds of data collection. The analysis compares changes in pressure over the three measurements for each intervention. |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Declan Patton, PhD | RCSI University of Medicine and Health Sciences | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| RCSI Education and Research Centre | Dublin | YN77 | Ireland |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D014647 | Varicose Ulcer |
| ID | Term |
|---|---|
| D014648 | Varicose Veins |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D007871 | Leg Ulcer |
Not provided
Not provided
Healthy volunteer study where participants serve as their own control, the control condition will be assigned to one leg and the experimental condition applied to the other leg.
Not provided
Not provided
The clinical research nurse applying the compression interventions will be blinded from interface pressure measurements
|
| Standard Compression | Device | Coban 2 represents the standard of care 2-layer compression wrap used to treat venous leg ulcers. The device consists of a comfort layer and a compression layer. A clinician applies the device to establish compression therapy. |
|
|
| Measured at 0 hours, 1 hour, and 4 hours on Day 1 |
| Average Interface Pressure while laying down | The participant lays down on the bed for 30 seconds. A pressure sensor (Pico Press) continuously measures compression at the medial gastrocnemius head. The interface pressure measurements are averaged over 30 seconds of data collection. The analysis compares changes in pressure over the three measurements for each intervention. | Measured at 0 hours, 1 hour, and 4 hours on Day 1 |
| Accuracy of Compression Therapy System Prototype compared to Interface Pressure | During data collection on day 1, the pressure sensor (Pico Press) will continuously monitor compression level applied to the calf. Researchers willl compare the pressure applied from the device to the measured pressure at the calf. | Measured between 0 and 4 hours on day 1 |
| Visual Analogue Sensory (Pain) Assessment | Pain assessment completed by a 0 to 10 visual analog scale where 0 represents no pain and 10 represents severe pain. | Measured on Day 1 at hour 4 |
| Visual Analogue Skin Redness Assessment | Visual Analogue Scale between 0 (no redness) to 10 (severe redness) | Measured on Day 1 at hour 4 for both interventions; Measured on Day 2 - 4 for Compression Therapy System Prototype |
| Usability Assessment | Questionnaire that allows research participants to score each intervention on a 1 (Strongly disagree) to 5 (Strongly agree) scale for the following questions: The intervention stayed in place while you are wearing it. The appearance of the intervention is aesthetically appealing The dimensions of the intervention are appropriate The weight of the intervention is comfortable when wearing it Overall I was able to successfully use the compression therapy prototype The user manual is helpful for me in managing the compression therapy prototype The instructions in the user manual are understandable (compression therapy prototype only) Overall, the Compression Therapy System Prototype is user friendly Overall, I feel comfortable when I use the intervention Overall, I feel confident when I use the intervention Overall I feel there is no risk to me when I use the intervention | Completed on Day 1 for both interventions and daily on Day 2, 3, and 4 for the compression therapy system prototype |
| At home usability assessment | Questions will be asked to healthy volunteers during three day period at home. Volunteers rate their response on a scale from 1 (strongly disagree) to 5 (strongly agree). I learned to use the compression therapy prototype quickly I learned to use the compression therapy prototype easily I easily remember how to use the compression therapy prototype I quickly became skillful with the compression therapy prototype It isn't necessary to have too much previous knowledge to use the compression therapy prototype The instructions for use are clear and easy to understand The LED signs from the compression therapy prototype is accurate Overall, I was able to successfully interpret the LED signs of the compression therapy prototype The LED signs of the compression therapy prototype are understandable and easy to interpret The LED signs were helpful for me in managing the compression therapy prototype The LED signs allow me to correct mistakes quickly and easily | Day 2 and 3 |
| D012883 |
| Skin Ulcer |
| D012871 | Skin Diseases |
| D017437 | Skin and Connective Tissue Diseases |