The PIONEER EV PACING Study is prospective, multi-center, acute (in-hospital), single-arm, pilot study. The study objective is to characterize preliminary safety and performance of the AtaCor EV Temporary Pacing Lead System when used as intended for clinical use as a temporary pacing lead.
The primary safety endpoint is freedom from Adverse Device Effects, CTCAE Grade 3 or higher. The primary performance endpoint is percentage of Subjects with demonstrated pacing capture following lead fixation.
Up to 30 subjects will be enrolled at up to three (3) investigation centers. Enrolled subjects will undergo insertion of a StealthTrac Lead within one calendar day of an eligible planned index procedure that requires a temporary pacing lead. Echocardiographic evaluations will be performed before and after StealthTrac Lead insertion, as well as after the index procedure, to assess for pericardial effusion. Post-operative fluoroscopic images are required in all subjects to document the final lead position. In subjects without an underlying ventricular escape rhythm, a concomitant, commercially available pacing lead is required. Lead measurements (Thresholds, Impedance, R-Waves) and an insertion procedure survey will be obtained.
Subjects will be restricted to bed rest while the StealthTrac lead remains inserted. The StealthTrac Lead will be connected to a commercially available, constant-current temporary pacemaker programmed by the investigator to provide temporary pacing support. The StealthTrac Lead will remain inserted until the next calendar day, at a minimum, and will be removed once the clinical need for temporary pacing ends. The maximum duration of lead insertion is two (2) days following the lead insertion procedure.
Follow up evaluations will be performed for as long as the StealthTrac Lead remains inserted. Subjects will also undergo a 30-day post-removal follow-up before completing participation. On the final follow-up, prior to StealthTrac Lead removal, Subjects may be tested in multiple postures. Subjects with pacing capture in the upright posture may have ECGs recorded during various isometrics or while walking with pacing from the StealthTrac Lead.
Prior to removal, a final lead evaluation will be performed and fluoroscopy will be used to document the final lead position. Echocardiographic imaging will be obtained before and after the removal procedure to characterize any new or worsened pericardial effusions. A final post-removal follow-up will be performed in person or remotely to document any latent adverse events.
The overall study is expected to last four (4) months, comprising two (2) months for enrollment and follow-up and two (2) months to monitor study data and prepare a final report.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| AtaCor EV Temporary Pacing Lead System | Experimental | Subjects implanted with the AtaCor StealthTrac Lead Model AC-101400 |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| AtaCor StealthTrac Lead | Device | Subjects will receive the AtaCor StealthTrac Lead being evaluated in the study. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Freedom from severe ADEs | Freedom from Adverse Device Effects, CTCAE Grade 3 or Higher | Up to 30 days post-lead removal |
| Percentage of Subjects with pacing capture | Percentage of Subjects with demonstrated pacing capture following lead fixation | Up to 2 days post-lead insertion |
Not provided
Not provided
Inclusion criteria
At least 18 years old
Subjects who:
Are undergoing one of the following planned (non-urgent) procedures that are associated with the potential need for temporary bradycardia pacing:
Subjects with bradycardia who are under evaluation to determine if the cause is transient or permanent
Exclusion criteria
BMI ≥ 35 kg/m2
Septic shock
Severe anemia
Patients on dual antiplatelet therapy or anti-coagulation that cannot be stopped for the procedure
Circumstances that prevent data collection or follow-up
Participation in any concurrent clinical study without prior written approval from the Sponsor
Inability or unwillingness to provide informed consent to participate in the Study
Known prior history for any of the following:
Median or partial sternotomy
Acute coronary syndrome within past 90 days
NYHA Functional Classification IV within past 90 days
Surgically corrected congenital heart disease (not including catheter-based procedures)
Allergies to the device materials such as stainless steel, titanium, platinum, iridium, polyethylene, polyurethane, polycarbonate and silicone
Surgery with disruption of the lung, pericardium or connective tissue between the sternum and pericardium, including adhesions
Significant anatomic derangement of or within the thorax (e.g., pectus excavatum, significant scoliosis)
Thoracic radiation therapy, pneumothorax, pneumomediastinum or other medical treatments which may complicate the AtaCor EV Temporary Pacing Lead System insertion procedure
Any conditions which may complicate the AtaCor EV Temporary Pacing Lead System insertion procedure
Pericardial disease, pericarditis and mediastinitis
Medical treatments, surgeries or conditions that increase the potential for pericardial adhesions
FEV1 < 1 liter
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Martin C Burke, DO | AtaCor Medical, Inc. | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Hospital Center Split | Split | 21000 | Croatia |
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided