In this trial we intend to evaluate the safety and effectiveness of the INSPIRIS valve prothesis in the pulmonary position in patients of five years or older, with congenital or acquired pulmonary valve disease, requiring replacement of their native or prosthetic pulmonary valve.
Up to 40 subjects will be invited to participate in this trial after the indication for pulmonary valve replacement has been established. At the inclusion visit, patients will be screened according to the inclusion / exclusion criteria. After written informed consent, a detailed history will be obtained, and the study related exams will be performed.
The procedure will be performed through a median sternotomy with the help of cardiopulmonary bypass in a beating or arrested heart fashion depending on the individual surgeon's discretion. Any additional or residual defects will concomitantly be addressed. Either a native or prosthetic pulmonary valve will be replaced by an Edwards Inspiris valve (Edwards Lifesciences, Unterschleissheim, Germany). If a conduit is required, the valve will be sewn into a suitable prosthesis beforehand.
Subjects will be seen regularly after pulmonary valve implantation at hospital discharge, 6-month, 1 year and 2 years after surgery. A cardiac magnetic resonance imaging will be performed at inclusion and 2 years after surgery.
Total enrollment period for the study is estimated to be two years. The trial starts with the enrollment of the first patients and ends after the last patient enrolled has completed the two-year visit or has exited the study.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Edwards Inspiris Resilia Valve |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Pulmonary valve replacement | Procedure | Surgical replacement of the pulmonary valve using the Edwards Inspiris Resilia prosthesis. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Freedom from death and reoperation | The primary safety endpoint for the trial is freedom from device or procedure related death and/or reoperation at 2 years after implantation. | 2 years after implantation |
| Measure | Description | Time Frame |
|---|---|---|
| Safety endpoints | all-cause mortality, structural valve deterioration, paravalvular leak, non-structural valve deterioration, transvalvular leak, trial valve-related mortality, endocarditis, valve thrombosis, explant and thromboembolism | 2 years after implantation |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Requires emergency surgery
Has acute myocardial infarction (MI) within 30 days prior to screening date
Has MRI or CT scan confirmed stroke, cerebrovascular accident (CVA) or transient ischemic attack (TIA) within six months prior to screening date
Has hemodynamic or respiratory instability requiring inotropic support, mechanical circulatory support, or mechanical ventilation within 30 days prior to screening date
Has active endocarditis/myocarditis or endocarditis/myocarditis within three months prior to screening date
Has renal insufficiency as determined by creatinine level ≥ 2.5 mg/dL within 60 days prior to screening visit or end-stage renal disease
Has documented:
9. Diagnosed with abnormal calcium metabolism and/or hyperparathyroidism 10. Echocardiographic evidence of an intra-cardiac mass, thrombus, or vegetation 11. RVOT aneurysm unless treated during pulmonary valve replacement surgery 12. Has prior organ transplant or is currently an organ transplant candidate 13. Was previously implanted with study trial device 14. Previously implanted with an aortic, mitral, or tricuspid bioprosthetic valve or mechanical valve 16. Has presence of non-cardiac disease limiting life expectancy to less than 12 months 17. Is currently or has recently participated (within six weeks) in another investigational drug or device trial 18. Positive urine or serum pregnancy test in female subjects of child-bearing potential and/or nursing mothers 20. Currently incarcerated or unable to give voluntary informed consent 21. Documented history of substance (drug or alcohol) abuse within the last five years prior to screening date
Not provided
Not provided
The study population consists of patients with pulmonary valve disease requiring pulmonary valve replacement of their native or prosthetic valve, equal to or greater than five years of age.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Daniel Zimpfer, Prof. PD. Dr. | Contact | + 43 1 40400 56200 | daniel.zimpfer@meduniwien.ac.at |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical University of Vienna | Recruiting | Vienna | 1090 | Austria |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006330 | Heart Defects, Congenital |
| ID | Term |
|---|---|
| D018376 | Cardiovascular Abnormalities |
| D002318 | Cardiovascular Diseases |
| D006331 | Heart Diseases |
| D000013 | Congenital Abnormalities |
Not provided
Not provided
Not provided
Not provided
Not provided
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |