Background Cardiac Resynchronization Therapy (CRT) is proven to improve survival and heart function of patient with certain electrical conduction abnormality and heart failure. However, in patient with certain electrical conduction abnormality, being nonresponder is observed in up to 40% in patient receiving CRT. Conventionally the surgical approach of CRT is to implant one pacing lead in the right heart and one in the left heart to resynchronize the contraction and the pacing lead in the left heart is usually placed in the posterior or lateral portion of the left heart. However, this single approach may not be optimal, especially for those patients with conduction abnormality known to have no response to CRT. Purpose of the clinical investigation The purpose of the Activation Pattern and Acute Hemodynamics of His and Left Bundle Pacing is to study the acute effect on the heart function and conduction abnormality of His and left bundle pacing in conventional CRT candidate. During CRT implantation, Hisbundle lead and Left bundle pacing lead will be placed and the acute effect on heart function will be studied by a wire placed in the left ventricle of the heart and the activation pattern will be studied by a noninvasive global mapping system. The pacing approach that optimally corrects conduction abnormality and improvement on the heart function acutely will be determined
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Tailor-made CRT delivery | Experimental | Cardiac resynchronization therapy given according to Electrical Activation Mapping result |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Electrical Activation Mapping Guided Cardiac resynchronization therapy | Device | To study the feasibility to optimize configuration of CRT delivery for acute correction of electrical dyssynchrony using a noninvasive mapping of global electrical activation |
| Measure | Description | Time Frame |
|---|---|---|
| Improvement in myocardiac activation | Correction of activation abnormality as evaluated by global noninvasive mapping system (ECGi) seen as an increase in acute dp/dt > 5% from baseline with left bundle pacing comparing to biventricular pacing. | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Procedure duration | Procedure duration of the optimal CRT delivery method as determined by the best improvement in electrical desynchrony indices. | during procedure |
| Implantation success rate | Implantation success rate of the optimal CRT delivery method as determined by the best improvement in electrical desynchrony indices. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Daniel Xu | Contact | 35051518 | danielxu@cuhk.edu.hk |
| Name | Affiliation | Role |
|---|---|---|
| Bryan Yan | Chinese University of Hong Kong | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| The Chinese University of Hong Kong | Recruiting | Shatin | 999077 | Hong Kong |
Not provided
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| during procedure |
| Cine images and chest X ray | Cine images (PA, LAO 300, RAO 300) and Chest X ray (PA view) obtained during course of study for assessment of disease | 6 months |
| Echocardiogram parameters: strain imaging | Echocardiogram parameters: strain imaging at baseline, 3 months and 6 months | 6 months |
| Echocardiogram parameters: left ventricular systolic and diastolic volume | Echocardiogram parameters: left ventricular systolic and diastolic volume at baseline, 3 months and 6 months | 6 months |
| Echocardiogram parameters: left ventricular ejection fraction | Echocardiogram parameters: left ventricular ejection fraction at baseline, 3 months and 6 months | 6 months |
| Echocardiogram parameters: degree of mitral regurgitation | Echocardiogram parameters at baseline, 3 months and 6 months | 6 months |
| Change in New York Heart Association class | Comparison of NYHA class at baseline, 3 months and 6 months to assess changes in quality of life of subject. | 6 months |
| Device parameter: defibrillation threshold | Electrical parameters including defibrillation threshold at implant and 6 months follow-up. | 6 months |
| post-operative complication rate | Peri-operative and 6 months follow-up complications rate:
| 6 months |
| Device parameter: defibrillation sensitivity | Electrical parameters including defibrillation sensitivity at implant and 6 months follow-up. | 6 months |
| Device parameter: lead impedance | Electrical parameters including lead impedance of pacing leads at addition of new lead and 6 months follow-up. | 6 months |
| Change in 6 minute hall walk test result | Comparison of 6 minute hall walk test result at baseline, 3 months and 6 months to assess changes in quality of life of subject. | 6 months |
| Change in HF Patient Global Assessment Questionnaire outcome | Comparison of HF Patient Global Assessment Questionnaire outcome at baseline, 3 months and 6 months to assess changes in quality of life of subject. | 6 months |