Evaluation on the reliability, practicability and safety of a wearable device for measuring arteriovenous fistula function based on voice print.
Arteriovenous fistula is the lifeline of maintenance hemodialysis patients. At present, there is a lack of a simple wearable real-time evaluation technology and device for arteriovenous fistula, which can help doctors find and deal with the complications of arteriovenous fistula timely and accurately. This study proposes an innovative design based on PVDF piezoelectric membrane by combining all kinds of technologies including NB-iot/4G transmission mode to realize real-time monitoring and feedback of the health status of arteriovenous fistula vessels, so that the use time of arteriovenous fistula can be prolonged and the survival rate of dialysis patients can also be improved.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Normal control group | Patients with no disease in the main organs, with well-developed body shape, and with good physiological functions, physical activity abilities and labor abilities. |
| |
| Newly established arteriovenous fistula group | Chronic kidney disease stage 5 (CKD5) non-dialysis patients planning to undergo internal arteriovenous fistula surgery. |
| |
| reconstructed arteriovenous fistula group | Patients with maintenance hemodialysis who need to reconstruct the internal arteriovenous fistula on account of dissatisfaction with blood flow. |
| |
| Long-term maintenance hemodialysis group | Patients undergoing hemodialysis with long-term fixed internal arteriovenous fistula. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| A device for detecting arteriovenous fistula vascular function | Device | An innovative design based on PVDF piezoelectric membrane by combining all kinds of technologies including NB-iot/4G transmission mode to realize real-time monitoring and feedback of the health status of arteriovenous fistula vessels |
| Measure | Description | Time Frame |
|---|---|---|
| Correlation between voiceprint spectrum and the blood flow of arteriovenous fistula | Correlation between voiceprint spectrum and the blood flow of arteriovenous fistula | 2 month |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Patients with end-stage renal disease undergoing or planning regular hemodialysis with autologous arteriovenous fistulas
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Ai Peng, MD,PhD | Contact | 86-21-66302524 | pengai@tongji.edu.cn | |
| Dayong Hu | Contact | 86-21-66302527 | shiyuanhudayong@sina.com |
| Name | Affiliation | Role |
|---|---|---|
| Ai Peng, MD,PhD | Shanghai 10th People's Hospital | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Nephrology & Rheumatology, Shanghai Tenth People's Hospital | Recruiting | Shanghai | Shanghai Municipality | 200272 | China |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|