We are testing the accuracy of Reichert's Tono-Vera tonometer by comparing measurements of IOP with this device and measurements with other commonly-used tonometers, including Goldmann Applanation and iCare.
This is a comparative study between the TonoVera, the gold standard Goldmann Applanation Tonometry (GAT) and an established rebound tonometry device, iCare. IOP measurements will be obtained using the following devices: Reichert's prototype Tono-Vera Rebound tonometer (a rebound tonometer in development), iCare's iC100 rebound tonometer (a device commonly used in clinical practice), GAT (a device commonly used in clinical practice). Reichert's iPac Handheld Pachymeter (a device commonly used in clinical practice) will be used to measure the test subject's Central Corneal Thickness (CCT), measured in µm if CCT is not already on file. An Autorefractor Keratometer (ARK) (a device commonly used in clinical practice) will be used to measure necessary vision correction and corneal curvature. The Ocular Response Analyzer (a device commonly used in clinical practice) will be used to measure corneal hysteresis. Multiple IOP measurements will be taken with each device on each eye for all subjects: 3 along the central cornea, 3 along the peripheral cornea, and 3 along the sclera.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| IOP Measurement | Other | These are the measurements of the intraocular pressure. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Tono-Vera tonometer | Device | The tonometer measures intraocular pressure with a small rebound probe, similar to those used with other tonometers currently on the market, such as the iCare. |
| Measure | Description | Time Frame |
|---|---|---|
| Intraocular Pressure | pressure inside the eye | Baseline only |
Not provided
Not provided
Inclusion Criteria:
Male or female patients aged 18 to 99 Patients in good general health as evidenced by ability to come to their appointment on day of study.
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Sandra Sieminski, MD | Contact | 716-408-6909 | smfernando17@gmail.com | |
| Catherine Seeger, MD | Contact | 5859443719 | cseeger2@buffalo.edu |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ross Eye Institute | Recruiting | Buffalo | New York | 14209 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31726999 | Background | Chen M, Zhang L, Xu J, Chen X, Gu Y, Ren Y, Wang K. Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group. BMC Ophthalmol. 2019 Nov 14;19(1):225. doi: 10.1186/s12886-019-1236-5. | |
| 18703945 | Background | Hager A, Loge K, Schroeder B, Fullhas MO, Wiegand W. Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, ocular response analyzer, and Goldmann tonometry in glaucomatous eyes. J Glaucoma. 2008 Aug;17(5):361-5. doi: 10.1097/IJG.0b013e31815c3ad3. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D005901 | Glaucoma |
| ID | Term |
|---|---|
| D009798 | Ocular Hypertension |
| D005128 | Eye Diseases |
Not provided
Not provided
We are comparing the accuracy of eye pressure measurements with a Tono-Vera device compared to the current gold standard, Goldmann Applanation Tonometry.
Not provided
Not provided
Not provided
Not provided
| Goldman Applanation Tonometry | Device | This is the current gold standard for measuring eye pressure. |
|
| 22310080 | Background | Kaushik S, Pandav SS, Banger A, Aggarwal K, Gupta A. Relationship between corneal biomechanical properties, central corneal thickness, and intraocular pressure across the spectrum of glaucoma. Am J Ophthalmol. 2012 May;153(5):840-849.e2. doi: 10.1016/j.ajo.2011.10.032. Epub 2012 Feb 4. |