Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Herlev and Gentofte Hospital | OTHER |
| VentriJect ApS | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Measurement of cardiorespiratory fitness (VO2max) is considered an important tool in risk prediction of cardiovascular disease and overall patient management. The gold standard method for determining VO2max is a maximal cardiopulmonary exercise test (CPET). This requires time, maximal exercise until voluntary exhaustion and expensive equipment and are therefor not always suitable. A non-exercise VO2max prediction model using seismocardiography (SCG) at rest in combination with demographic data has been proposed as an possible alternative. SCG is a non-invasive three-dimensional measurement technique of precordial vibrations caused by the beating heart and can provide information on cardiac performance. New advances in low-weight three-axis accelerometer, signal processing and feature selection has made this methodology attractive in the recent years. VentriJect Aps has develop a medical device for measuring SCG (SeismoFit) together with an cloud solution for signal processing and prediction of VO2max. The validity of the SeismoFit device has previously been assesses in healthy subjects, but not yet in patients.
The aim of this study is therefore to investigate the validity of the SeismoFit VO2max estimation in patients with heart failure (HF) or ischemic heart disease (IHD).
The study is composed of three parts in order to investigate the validity and reliability of the SeimsoFit VO2max estimation.
1) A cross-sectional part: 80 patients with HF and 60 patients with IHD are recruited for this part. An interim data analysis is planed after 50% of the patients have been through testing, in order to allow for algorithm adjustment, before the data analysis of the last 50% are performed. This part requires one test day.
2) A longitudinal part: 60 patients with HF and 40 patients with IHD are recruited to perform a follow-up test (from part 1) after being medical customized to the treatment doses. This is typically within 3-4 month, depending on the patient.
This part requires one follow-up test day in addition to the test in part 1.
3) A test-retest part: 20 HF and 20 IHD patients are recruited for this part. This part requires one test day within 2-7 days after the last test in part 2.
The testing procedures are identical for the different study parts and includes:
Data from echocardiography measurement and blood samples performed during the standard care treatment at the hospital will be available in this study.
Statistical analysis:
All data will be checked for normal distribution (Shapiro-Wilk test) and equal variance (Brown-Forsythe test). The significant level is p<0.05.
Validity assessment of the SeismoFit VO2max estimation compared with the CPET measured VO2max for HF and IHD patients will be analysed with; A Student's paired t-test or a mixed effect model (part 2), Pearson correlation coefficient r, Standard Error of Estimate (SEE), Mean Absolute Percentage Error (MAPE), Coefficient of Variation (CV%) and Bland-Altman analysis with 95% limits of agreement (BA-plot). Pearson r interpretation is: very high > 0.90, high 0.70-0.90, moderate 0.50-0.70, low 0.30-0.50 and little if any 0.00-0.30. SEE is calculated using: =√(Y-Y')/n-2, with Y representing CPET VO2max and Y' representing SeismoFit VO2max. SEE interpretation is: very good < 4.0 ml/min/kg, good 4.0-6.0 ml/min/kg, fair 6.0-8.0 ml/min/kg, poor 8.0-10.0 ml/min/kg and > 10.0 ml/min/kg very poor. A MAPE ≤ 10% will be used as a criteria level for the SeismoFit VO2max estimation to be considered clinically relevant.
Reliability assessment is analysed with a mixed-effect model, within-subject standard deviation, CV% and Pearson r. The within-subject standard deviation is calculated taking the squared root of the within-subject variance. Statistical analyses will be performed, and figures constructed in R Studio, GraphPad Prism and Microsoft Excel.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| HF | Patients with heart failure. | ||
| IHD | Patients with ischemic heart disease. |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Validity of SeismoFit VO2max estimation in HF and IHD patients | Assessment of VO2max at rest with SeismoFit and with a gold standard CPET. The validity of the SeismoFit will be based on difference and agreement between the two test methods for both hart failure patients and patients with ischemic heart disease. | 1 day |
| Measure | Description | Time Frame |
|---|---|---|
| Detection of change in VO2max using SeismoFit | A follow-up test day after meeting the medical treatment doses in order to investigate if the SeismoFit is able to detect changes in VO2max following medical treatment and physical rehabilitation in these patient groups. The validity of SeismoFit will be based on difference and agreement between pre and post standard medical treatment compared with CPET. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Patients with heart failure: HFrEF (LVEF < 40%) and NYHA I-III.
And
Patients with Ischemic heart disease
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Jørn W Helge, Professor | Contact | +45 28757506 | jhelge@sund.ku.dk |
| Name | Affiliation | Role |
|---|---|---|
| Jørn W Helge, Professor | Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Herlev and Gentofte Hospital | Recruiting | Gentofte Municipality | 2900 | Denmark |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 41574039 | Derived | Hansen MT, Hashiba M, Nielsen SK, Petersen CS, Saederup RG, Schmidt SE, Wolsk E, Helge JW, Lamberts M. Non-exercise estimation of peak oxygen uptake in patients with ischaemic heart disease and heart failure using seismocardiography. Eur Heart J Digit Health. 2025 Sep 2;7(1):ztaf095. doi: 10.1093/ehjdh/ztaf095. eCollection 2026 Jan. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| D017202 | Myocardial Ischemia |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D014652 | Vascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| 4-5 month |
| Reliability of the SeimoFit VO2max estimation | A test day performed within 2-7 days after the follow-up test day in order to assess reliability of the SeismoFit estimation. The reliability will be based on intra-method variation between the two test days. | 7 days |