The Hanita Lenses Intensity SL IOL is intended for implantation in the capsular bag in the posterior chamber in order to replace the crystalline lens of the eye to attain visual correction of aphakia in adult patients in whom a cataractous lens has been removed, who desire improved uncorrected vision, useful near, intermediate and far visual functions, and reduced spectacle dependence.
Different multifocal intraocular lens (MIOL) designs have been used for more than 25 years1. Unlike conventional mono focal intraocular lenses (IOLs), which bend light to a single focus point on the retina, MIOLs are designed to help patients to see at varying distances using different points of focus2. MIOLs used in clinical practice were either refractive initially, or later diffractive in their optical design. Refractive MIOLs incorporate a lens optic with different optical powers in different parts of the lens, while diffractive MIOLs use diffractive steps on the lens to distribute light rays into two or more principal foci. Irrespective of the design type, however, all MIOLs involve some form of optical compromise and a process of neuroadaptation for the patient3.
Intensity SL intraocular lenses (IOLs) represent the latest in premium lens technology. Intensity SL lenses provide clear vision at all distances - from near to far - thus offering the best chance of true spectacle independence.
Despite the promising results obtained with the latest generation of MIOLs, many surgeons remain reluctant to implant these lenses. Visual symptoms such as glare and haloes, reduced contrast sensitivity and night vision problems are all known complications of multifocal implants and have served to hamper wider acceptance of these IOLs4.
Hanita Lenses new Intensity SL IOL has been designed to have very high efficiency of light leading to a high MTF, wide focal ranges of far, intermediate and near vision and minimal loss of light energy. The main purpose of this study is to evaluate visual acuity and contrast sensitivity patients receiving the new Intensity SL IOL.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Single Arm | Other | This study is a prospective, single arm single center, open label study. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| "Intensity SL" Intraocular Lens | Device | Cataract surgery and intraocular lens implantation |
|
| Measure | Description | Time Frame |
|---|---|---|
| Binocular Visual Acuity | Binocular visual acuity for far, intermediate and near distance are measured using an ETDRS chart or PV numbers for distance and PV Numbers Near Vision Card (Precision Vision) for near (40cm) and intermediate distances (80cm). Visual acuity is measured in photopic conditions. | 3 months |
| Measure | Description | Time Frame |
|---|---|---|
| Defocus Curve | Defocus Curve is measured using ETDRS chart or PV numbers. A loss of ≥ 3 lines (≥ 15 letters) on an ETDRS chart is considered moderate visual loss. A loss of ≥ 6 lines (≥ 30 letters) is considered severe. Patient's pupil diameter will be evaluated using a phoropter to create defocus in 0.5D increments, starting from 1D to -4D relative to emmetropia so that the patient will be corrected for far vision. |
| Measure | Description | Time Frame |
|---|---|---|
| Toxicity after IOL implantation | Occurrence of adverse events associated with treating patients diagnosed with binocular cataract with Intensity SL IOL implantation. | 3 months |
Inclusion Criteria:
• Age over 45 years and under 75 years.
Patients with bilateral age related cataracts, require bilateral cataract phacoemulsification combined Intraocular Lens implantation;
Calculated IOL power is within range 15-30 Diopter (approximate range of axial lengths: 21-25.5mm)
Normal corneas with corneal astigmatism below following value:
Post-operative best corrected visual acuity expected to be 0.3 logMAR or better.
Patient motivated for Intensity SL IOL after screening by surgeon.
Fundus visualization is possible.
Absence of retinal or optic nerve diseases
Signed informed consent
Exclusion Criteria:
Any of the following condition will render a subject ineligible for inclusion in the analysis:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Dr. Suvodip Shaw | Dr. Agarwal's Eye Hospital Limited | Study Director |
| Dr Ashvin Agarwal | Dr. Agarwal's Eye Hospital Limited | Principal Investigator |
| Priyanka S. | Dr. Agarwal's Eye Hospital Limited | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Agrawal | Chennai | India |
Not provided
| ID | Term |
|---|---|
| D002386 | Cataract |
| ID | Term |
|---|---|
| D007905 | Lens Diseases |
| D005128 | Eye Diseases |
Not provided
Not provided
single arm single center, open label study
Not provided
Not provided
Not provided
Not provided
| 3 months |
| Contrast Sensitivity | Contrast Sensitivity is measured using a sine wave gratings chart (FACT) at mesopic and photopic conditions. Luminance for photopic conditions will be 85cd/m² and 5cd/m² for mesopic conditions. The working interval for photopic conditions is 75-95cd/m² and for mesopic conditions is 5-15cd/m². Luminance for photopic and mesopic conditions will be monitored using Illuminance meter and documented. | 3 months |
| Patients Satisfaction | Patient Satisfaction is measured using the modified VF-14 questionnaire for quality of life, in addition to satisfaction questionnaire. VF-14 stands for Visual Function questionnaire version 14. Function: High score = better Visual Phenomenon: High score = better Satisfaction: Very happy / Happy / Less Happy / Unhappy | 3 months |