Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The DS Prime Taper EV dental implant system was recently launched on the implant market by Dentsply Sirona (York, PA, USA).
Dental implant systems are undergoing rapid evolution, ultimately driven by their broad therapeutic indications. As manufacturers strive to keep up with the demands of a growing market, designs are changing faster than clinical evaluation. This means that the time needed to assess medium- and long-term clinical outcomes before designs change again cannot be met.
Clinicians need to have a "real" analysis of the clinical performance of implants before using them. Therefore, reporting of results is necessary to avoid use in patients without proper practical checks even before the recommended 10- and 15-year follow-up periods.
The DS PrimeTaper implant has macro-design features that differ from its predecessor, the OsseoSpeed EV implant (AstraTech Implant System EV, Dentsply Implants, Mölndal, Sweden) with which they share a common surface and internal connection.
Its macro-design has been modified through the introduction of variable thread forms and a more pronounced taper, ultimately making it more aggressive in terms of cutting ability.
While its predecessor, the OsseoSpeed EV implant, has sufficient scientific support, this new system recently introduced on the market does not. All the scientific contributions that can be made will therefore be a first guide for the clinician who wishes to start using this dental implant system.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients DS Prime Taper | Patients who receive al least one DS Prime Taper on his dental implant treatment. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Implant Treatment | Device | Surgical placement of a DS Prime Taper implant and its posterior prosthesis. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Implant Survival Rate | Time of survival of DS Prime Taper dental implant placed | through study completion, an average of 1 year |
| Implant Success Rate | Radiological assessment of Marginal Bone Levels around DS Prime Taper implants in function | through study completion, an average of 1 year |
| Biological and mechanical complications events | All type of complications that may occur during implant survival | through study completion, an average of 1 year |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients receiving DS Prime Taper dental implant in a private dental office.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Guillem Esteve-Pardo, PhD | Contact | +34965215755 | guillem@clinicaesteve.com |
| Name | Affiliation | Role |
|---|---|---|
| Guillem Esteve-Pardo, PhD | ClĂnica Dental Esteve | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| ClĂnica Dental esteve | Recruiting | Alicante | Alicante | 03001 | Spain |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 27447160 | Result | Stanford CM, Barwacz C, Raes S, De Bruyn H, Cecchinato D, Bittner N, Brandt J. Multicenter Clinical Randomized Controlled Trial Evaluation of an Implant System Designed for Enhanced Primary Stability. Int J Oral Maxillofac Implants. 2016 Jul-Aug;31(4):906-15. doi: 10.11607/jomi.4869. | |
| 31591290 | Result | Choi NH, Yoon HI, Kim TH, Park EJ. Improvement in Fatigue Behavior of Dental Implant Fixtures by Changing Internal Connection Design: An In Vitro Pilot Study. Materials (Basel). 2019 Oct 7;12(19):3264. doi: 10.3390/ma12193264. |
Not provided
Not provided
The data that support the findings of this study will be available on request from the corresponding author once publication is accomplished.
Once study completion date reached
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 28834532 | Result | Toia M, Galli S, Cecchinato D, Wennerberg A, Jimbo R. Clinical Evidence of OsseoSpeed EV Implants: A Retrospective Study and Characterization of the Newly Introduced System. Int J Periodontics Restorative Dent. 2019 November/December;39(6):863-874. doi: 10.11607/prd.2549. Epub 2017 Aug 23. |