Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Post-Prostatectomy Incontinence (PPI) is a common complication affecting 1% to 40% of patients after surgery. When conservative treatments fail, the installation of an artificial urinary sphincter (AUS) has been the treatment of choice for PPI since its introduction more than 50 years ago. Although small studies suggest inferior success rate of male slings compare to the AUS in moderate to severe male incontinence; recent studies, one prospective and one Canadian multicenter cohort study, have demonstrated adjustable transobturator male sling (ATOMS) as a safe and efficient alternative to treat PPI. Interestingly, the ATOMS does not required any operation manipulation from the user in order to void and it causes potentially less urethral erosion and less urethral atrophy than the AUS; although those findings were never compared head to head with the AUS. Therefore, we believe that a thorough prospective non-inferiority study comparing the outcomes and effectiveness of the ATOMS device versus the AUS in treating moderate to severe PPI could prove itself useful in guiding urologists and patients to choose their best treatment of male incontinence. The null hypothesis posed for the present study is that ATOMS is non inferior to AUS for the treatment of moderate to severe PPI using the non-inferiority margin of 15% to be of acceptable lower effectiveness.
With regards to study methods, this will be a pilot prospective, randomized controlled trial, non-blinded with a non-inferiority design. This pilot study will take place at the CIUSSS de l'Estrie, in Sherbrooke, Quebec, Canada, with two surgeons. All male patients with moderate to severe incontinence after their prostate surgery, who are suitable for incontinence surgery will be screened for study eligibility respecting the exclusion and inclusion criteria. After written informed consent, enrolled patients will be randomized assigned (1:1) to one of the two interventions' arms (AUS or ATOMS). Sixty patients are estimated to be randomized in the two arms the day of their surgery with a computer-based algorithm sequence.
By completing this pilot prospective study, we hope to provide concrete and scientifically significant evidence on the effectiveness of ATOMS in the treatment of moderate to severe PPI comparing with the AUS. Although both treatments are commonly used today, there has been little evidence comparing both devices side by side with more severe PPI. We therefore hope to make a global impact with said project.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Adjustable Transobturator Male System | Experimental |
| |
| Artificial Urinary Sphincter | Active Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Adjustable Transobturator Male System | Device | The ATOMS sling was developed in 2008 by Agency for Medical Innovations GmbH in Austria. It is a self-anchoring adjustable system which supports the bulbar urethra dorsally and uses the trans obturator approach. This device gained its fame in the male sling scene by being adjustable, which theoretically makes it more efficacious than its competitors. |
| Measure | Description | Time Frame |
|---|---|---|
| To compare effectiveness of the ATOMS and AUS devices in patients using results from the Patient Global Impression of Improvement (PGI-I) questionnaire. | Three years | |
| To compare effectiveness of the ATOMS and AUS devices in patients using results from the 24-hour pad test. | Three years |
| Measure | Description | Time Frame |
|---|---|---|
| To compare complication rates of the AUS and ATOMS using the Clavien-Dindo Classification. | Three years | |
| To compare effectiveness of the AUS and ATOMS devices in patients using results from the ICIQ-UI SF questionnaire. | Three years |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Le Mai Tu, MD, FRCSC | Contact | (819) 346-1110 | 74595 | Le.Mai.Tu@uSherbrooke.ca |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hôpital Fleurimont- Centre Hospitalier de l'Université de Sherbrooke | Recruiting | Sherbrooke | Quebec | J1E0G3 | Canada |
Not provided
| ID | Term |
|---|---|
| D014550 | Urinary Incontinence, Stress |
| D014549 | Urinary Incontinence |
| ID | Term |
|---|---|
| D014555 | Urination Disorders |
| D014570 | Urologic Diseases |
| D052776 | Female Urogenital Diseases |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
Not provided
Not provided
| ID | Term |
|---|---|
| D016741 | Urinary Sphincter, Artificial |
| ID | Term |
|---|---|
| D019736 | Prostheses and Implants |
| D004864 | Equipment and Supplies |
| D001187 | Artificial Organs |
| D013523 | Surgical Equipment |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Artificial Urinary Sphincter | Device | The AMS800™, which is by far the most frequently implanted AUS, was first marketed in 1983 and was developed by America Medical Holdings in Minnesota. Today, the AUS has been given the title "gold standard" for surgical treatment for PPI. This device is an inflatable cuff which wraps around the urethra to supply circumferential pressure. It has a control pump, which is found in the scrotum and is operated by the patient. The patient can void simply by squeezing the pump, which brings the fluid from the cuff to a reservoir and release the pressure around the urethra. The cuff is then automatically refilled with fluid within a couple of minutes to close back the sphincter. |
|
| To compare effectiveness of the AUS and ATOMS devices in patients using results from the ICIQ-OAB questionnaire. | Three years |
| To compare effectiveness of the AUS and ATOMS devices in patients using results from the ICIQ-MLUTS LF questionnaire. | Three years |
| To compare effectiveness of the AUS and ATOMS devices in patients using results from the IPSS-QoL questionnaire. | Three years |
| To assess the impact of OAB and radiotherapy on the effectiveness of AUS and ATOMS using results from the Patient Global Impression of Improvement (PGI-I) questionnaire. | Three years |
| To assess the impact of OAB and radiotherapy on the effectiveness of AUS and ATOMS using results from the 24-hour pad test. | Three years |
| To assess the impact of OAB and radiotherapy on the safety of AUS and ATOMS using Clavien-Dindo Classification to report adverse event frequency and severity. | Three years |
| To assess the impact of OAB and radiotherapy on the effectiveness of AUS and ATOMS using results from the ICIQ-UI SF questionnaire. | Three years |
| To assess the impact of OAB and radiotherapy on the effectiveness of AUS and ATOMS using results from the ICIQ-OAB questionnaire. | Three years |
| To assess the impact of OAB and radiotherapy on the effectiveness of AUS and ATOMS using results from the ICIQ-MLUTS LF questionnaire. | Three years |
| To assess the impact of OAB and radiotherapy on the effectiveness of AUS and ATOMS using results from the IPSS-QoL questionnaire. | Three years |
| To assess the impact of OAB and radiotherapy on the effectiveness of AUS and ATOMS using results from the 24-hour pad-count. | Three years |
| To compare effectiveness rates of the AUS and ATOMS using the results of the 24-hour pad-counts. | Three years |
| D000091642 | Urogenital Diseases |
| D052801 | Male Urogenital Diseases |
| D059411 | Lower Urinary Tract Symptoms |
| D020924 | Urological Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |