| Name | Class |
|---|---|
| Spanish Society of Cardiology | OTHER |
Not provided
Not provided
Not provided
Cardiac resynchronization therapy (CRT) via biventricular (BiV) pacing significantly reduces morbidity and mortality in patients with left bundle branch block (LBBB), impaired LV function and heart failure in spite of optimal medical treatment. CRT positive effects are based on the existence of an electromechanical dyssynchrony induced by the abnormal activation sequence associated with the presence of a left bundle branch block (LBBB), which is thought to be responsible for a negative LV remodeling leading to LVEF impairment and heart failure progression. However, one third of patients undergoing CRT are considered non responders due to different reasons. Recently, left bundle branch area pacing (LBBAP) has emerged as a novel physiological pacing modality aiming for conduction system recruitment in patients with normal or impaired atrioventricular conduction, including patients with LBBB. LBBAP achieves LBBB correction in up to 85% of the cases and thus could be a promising pacing modality for CRT candidates.
Medical device: Only CE-marked CRT-P or CRT-D Medtronic devices locally approved and commercially available (Medtronic 3830 Pacing Lead) shall be used in this protocol.
Indication: Pacing and sensing in the right atrium or ventricle. It is also designed for pacing and sensing in the bundle as an alternative to pacing in the right ventricle in a single or dual chamber pacing system.
Intended use: Patients with an indication for cardiac resynchronization therapy.
Duration of the study: Approximate inclusion period of 18 months
Follow-up: Patients will be followed for 12 months ± 4 weeks after implant
Planned study period: The study is planned to start in Q1 2022
No. of sites: Approximately 11 sites in Spain.
No. of subjects: 176 patients will be enrolled in the study
Study type: Post-market study
Study rationale: Previous studies show 85% implantation success, significant reduction in QRS duration, and significant improvement in NYHA functional class, LVEF, and LV end-diastolic diameter. Left bundle branch pacing could be an alternative to conventional biventricular pacing.
Study design: Multicenter, prospective, randomized, non-inferiority, open.
Objectives of the study:
Primary Outcome Measures: Improved Clinical Composite Score or ≥15% reduction in left ventricular end-systolic volume at 6 months follow-up.
Participating sites:
Study population: Subjects 18 years of age or older will be included in the study. Both sexes are eligible to participate. Subjects must present a left bundle branch block (according to Strauss criteria) with indication of CRT class I or IIa according to clinical practice guidelines. A selection of the subjects will be made before inclusion following the selection clinical investigation plan. After confirming that the subject meets the inclusion criteria and does not meet the exclusion criteria, they will be included in the clinical study.
Study population criteria:
Device Implantation Procedure: CRT obtained by biventricular pacing vs. CRT obtained by stimulating the left branch area.
Follow-up: Follow-up should be carried out with pre-established periodic clinical appointments 3, 6, and 12 months after hospital discharge. In the follow-up, routine examinations such as vital signs, electrocardiogram and echocardiogram (6 and 12 months) are recorded to check the evaluation of the reverse ventricular remodeling response and asynchrony parameters based on echocardiographic data.
Statistical considerations: Once patients have signed the informed consent at baseline visit, patients will be considered as "Enrolled population" in the statistical analysis. The sample size is based on the primary endpoint: Improved Clinical Composite Score or ≥15% reduction in left ventricular end-systolic volume at 6 months follow-up, showing that LBBAP is non-inferior to BiV-CRT. Accounting for a global attrition rate of 10% and considering the block size for randomization, 176 patients shall be enrolled.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Cardiac resynchronization therapy (CRT) obtained by stimulating the left branch area | Experimental | The CRT-P/CRT-D device and leads should be implanted according to the physician's standard practice. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. It is strongly encouraged the designation of a single and experienced implanting physician at each center for the LBBAP implant procedures. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). For LBBAP, the Medtronic 3830 lead will be used. Acceptable LBBAP threshold should be <2,5V@0,5ms. |
|
| Cardiac resynchronization therapy (CRT) obtained by biventricular pacing | Active Comparator | The CRT-P/CRT-D device and leads should be implanted according to the physician's manual provided with the devices. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. Investigators may use any market approved right atrial (RA) pace/sense lead, right ventricular (RV) pacing/defibrillator lead with pace/sense capabilities and any market approved unipolar/bipolar/quadripolar LV pacing lead. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). The LV lead should be implanted at a lateral or posterolateral CS branch in a basal or mid ventricular position confirmed by ortogonal fluoroscopic views (RAO and LAO 40º). Acceptable LV pacing threshold should be <3V@0,5ms and phrenic nerve stimulation (PNS) margin should be >1V with respect to the pacing threshold |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Cardiac resynchronization therapy | Device | Standard BiV-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's manual provided with the devices. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. The LV lead should be implanted at a lateral or posterolateral CS branch in a basal or mid ventricular position confirmed by ortogonal fluoroscopic views (RAO and LAO 40º). Acceptable LV pacing threshold should be <3V@0,5ms and phrenic nerve stimulation (PNS) margin should be >1V with respect to the pacing threshold. LBBAP-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's standard practice. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). For LBBAP, the Medtronic 3830 lead will be used. Acceptable LBBAP threshold should be <2,5V@0,5ms |
| Measure | Description | Time Frame |
|---|---|---|
| CRT response | Positive CRT response will be defined either by an improved Clinical Composite Score or ≥15% reduction in left ventricular end-systolic volume | 6 months follow-up |
| Measure | Description | Time Frame |
|---|---|---|
| Left ventricular ejection fraction | To evaluate left ventricular ejection fraction at 6 and 12 months follow-up | 6 and 12 months follow-up |
| Clinical outcome | Assessed by the Clinical Composite Score |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital General Universitario de Alicante Doctor Balmis | Alicante | Alicante | Spain | |||
| Hospital Universitario de Bellvitge |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002037 | Bundle-Branch Block |
| D006333 | Heart Failure |
| D018487 | Ventricular Dysfunction, Left |
| ID | Term |
|---|---|
| D006327 | Heart Block |
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D058406 | Cardiac Resynchronization Therapy |
| ID | Term |
|---|---|
| D002304 | Cardiac Pacing, Artificial |
| D004599 | Electric Stimulation Therapy |
| D013812 | Therapeutics |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| 6 and 12 months follow-up |
| Exercise capacity | Assessed by 6 minute walking test | 6 and 12 months follow-up |
| The EQ-5D three-level version (EQ-5D-3L) | Is a generic measure of health status consisting of 2 parts. The first assesses health in five dimensions (mobility, selfcare, usual activities, pain / discomfort, anxiety / depression), each of which has 3 levels of response (no problems, some problems, extreme problems / unable to). This part of the questionnaire provides a descriptive profile that can be used to generate a health state profile. Each health state can potentially be assigned a summary index score based on societal preference weights for the health state. Health state index scores generally range from less than 0 (where 0 is a health state equivalent to death; negative values are valued as worse than death) to 1 (perfect health), with higher scores indicating higher health utility. The second part consists of a VAS on which the patient rates his / her perceived health from 0 (the worst imaginable health) to 100 (the best imaginable health) | 6 and 12 months follow-up |
| Heart Failure Hospitalizations | Assessment of heart failure hospitalizations | 6 and 12 months follow-up |
| Mortality | To evaluate mortality (global and cardiovascular) | 6 and 12 months follow-up |
| Cardiac transplantation | To evaluate the need for cardiac transplantation during follow-up | 6 and 12 months follow-up |
| Ventricular arrhythmias | To evaluate incidence of ventricular arrhythmias (clinical and registered by the ICD/PM) | 6 and 12 month follow-up |
| Device related complications | Device related complications needing re-intervention | 6 and 12 month follow-up |
| L'Hospitalet de Llobregat |
| Barcelona |
| 08907 |
| Spain |
| Hospital Universitario Virgen de las Nieves | Granada | Granada | 18014 | Spain |
| Hospital Universitario San Cecilio | Granada | Granada | 18016 | Spain |
| Hospital Universitario Juan Ramón Jiménez | Huelva | Huelva | 21005 | Spain |
| Hospital 12 Octubre | Madrid | Madrid | 28041 | Spain |
| Hospital Universitario Puerta De Hierro | Majadahonda | Madrid | 28222 | Spain |
| Hospital Universitario Virgen de la Arrixaca | Murcia | Murcia | Spain |
| Hospital Universitari i Politècnic La Fe | Valencia | Valencia | 46026 | Spain |
| Hospital Clínico Universitario Lozano Blesa | Zaragoza | Zaragoza | 50009 | Spain |
| D000075224 |
| Cardiac Conduction System Disease |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D018754 | Ventricular Dysfunction |