Ineffective ablation lesions can cause arrhythmia recurrence after catheter ablation for cardiac arrhythmia. Ablation lesions can be created with various ablation energy modalities. This study uses cardiovascular magnetic resonance imaging to evaluate the ablation lesion characteristics of radiofrequency ablation, ultra-low temperature cryo ablation, and pulsed field ablation. The ablation lesion characteristics of different energy characteristics will be compared. Additionally, arrhythmia recurrence and quality of life will be evaluated for the different energy modalities.
Catheter ablation has become a cornerstone in the treatment of atrial fibrillation (AF). Typically, radiofrequency ablation (RFA) and cryoballoon ablation are used to perform pulmonary vein isolation (PVI). This treatment is effective in the majority of patients, but nevertheless 35% of patients have arrhythmia recurrence at 1-year follow up. These recurrence rates have been attributed to multiple factors, including ineffective ablation lesions, presence of non-pulmonary vein arrhythmia triggers, and disease progression.
Ineffective ablation lesions can cause arrhythmia recurrence through electrical reconnection. Electrical reconnection can occur when gaps are present in the ablation line due to non-durable, non-transmural or non-contiguous ablation lesions. Conventionally, ablation lesion assessment is performed using a redo electrophysiology study at three months post-ablation. During a redo electrophysiology study, a catheter is used to measure the local electrical signals to enable identification of sites with electrical reconnection. This method is effective but poses the patient to the procedural risks of these invasive measurements. Cardiovascular magnetic resonance (CMR) imaging may provide an alternative method for the evaluation of ablation lesions. Modern acquisition and post-processing techniques are under development and being used to image the atrial wall. These techniques may effectively visualize the fibrous tissue of ablation lesions, which enables a non-invasive method to characterize the lesions of catheter ablation.
To reduce arrhythmia recurrence caused by electrical reconnection, several novel ablation techniques have been developed in the last years. These novel ablation techniques can potentially reduce arrhythmia recurrence by enabling the creation of durable, transmural and contiguous ablation lesions. Novel ablation modalities include ultra-low temperature cryoablation (ULTC) and pulsed field ablation (PFA) that use near-critical nitrogen and pulsed electrical fields to create ablation lesions. The initial clinical outcomes of both ablation modalities are favorable, but little data are available on the ablation lesion characteristics. Additionally, novel techniques were developed to improve the procedural outcomes of RFA. High power, short duration (HPSD) RF energy applications cause more resistive and less conductive tissue heating compared to convention RFA, which results in more durable ablation lesions and less arrhythmia recurrence while safety outcomes are similar.
This study aims to use CMR to evaluate the ablation lesion characteristics of HPSD RFA, ULTC and PFA. This novel information can be used to quantitatively compare different ablation modalities. Furthermore, this study could contribute to our knowledge on ablation lesion formation, which may be used to further develop our ablation strategies.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Radiofrequency ablation, High power, short duration | Radiofrequency ablation is an ablation modality that uses radiofrequency energy to create ablation lesions through heat. Patients that are scheduled for pulmonary vein isolation using radiofrequency ablation will be consented for study participation. |
| |
| Ultra-low temperature cryo ablation | Ultra-low temperature cryo ablation is an ablation modality that uses nitrogen near its liquid-vapor critical point to create ablation lesions through ultra-low temperatures. Patients that are scheduled for pulmonary vein isolation using ultra-low temperature cryo ablation will be consented for study participation. |
| |
| Pulsed field ablation | Pulsed field ablation is an ablation modality that uses short lived electrical fields to create ablation lesions through irreversible electroporation. Patients that are scheduled for pulmonary vein isolation using pulsed field ablation will be consented for study participation. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Catheter ablation | Device | An ablation catheter is introduced in the heart. Ablation is performed by applying ablation energy to the target tissue. The aim of ablation is to create an ablation lesion that does not conduct the electrical signals that induce or sustain the cardiac arrhythmia. |
| Measure | Description | Time Frame |
|---|---|---|
| Length of gaps in the ablation lesions | Cardiovascular magnetic resonance imaging is used to visualize the ablation lesion. If gaps are present in the ablation lesion, the length of the gaps is measured in millimeter. | At 3 months follow up |
| Measure | Description | Time Frame |
|---|---|---|
| Number of gaps in the ablation lesion | Cardiovascular magnetic resonance imaging is used to visualize the ablation lesion. The number of gaps in the ablation lesion are counted. | At 3 months follow up |
| Location of gaps in the ablation lesion |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
The studied population will be drawn from all patients that are scheduled for catheter ablation at the participating center.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Lucas VA Boersma, MD, PhD | Contact | 0883200900 | +31 | l.boersma@antoniusziekenhuis.nl |
| Bob GS Abeln, MD | Contact | 0883201212 | +31 | b.abeln@antoniusziekenhuis.nl |
| Name | Affiliation | Role |
|---|---|---|
| Lucas VA Boersma, MD, PhD | St. Antonius Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| St. Antonius Hospital | Recruiting | Nieuwegein | 3435 CM | Netherlands |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001281 | Atrial Fibrillation |
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
Not provided
Not provided
| ID | Term |
|---|---|
| D017115 | Catheter Ablation |
| ID | Term |
|---|---|
| D000078703 | Radiofrequency Ablation |
| D000078702 | Radiofrequency Therapy |
| D013812 | Therapeutics |
| D055011 | Ablation Techniques |
Not provided
Not provided
Not provided
Not provided
Not provided
|
Cardiovascular magnetic resonance imaging is used to visualize the ablation lesion. If gaps are present in the ablation lesion, the location of the gaps is recorded.
| At 3 months follow up |
| Recurrence of atrial arrhythmia | Ambulatory rhythm monitoring will be performed at 3 and 12 months follow up to assess for recurrences of atrial arrhythmia (i.e. atrial fibrillation, atrial flutter, atrial tachycardia). Additionally, planned and symptom-driven electrocardiograms are assessed for atrial arrhythmia. | Until 1 year of follow up |
| Atrial arrhythmia burden | Ambulatory rhythm monitoring will be performed at baseline, 3 and 12 months follow up to assess the atrial arrhythmia (i.e. atrial fibrillation, atrial flutter, atrial tachycardia) burden (proportion of time in atrial arrhythmia). | Baseline, 3 and 12 months follow up |
| Atrial fibrillation related quality of life | A validated questionnaire (AFEQT) will be used to evaluate the atrial fibrillation related quality of life at baseline, 3 and 12 months follow up. | Baseline, 3 and 12 months follow up |
| D013568 |
| Pathological Conditions, Signs and Symptoms |
| D013514 |
| Surgical Procedures, Operative |