This prospective cohort study enrolled patients with implantation of a trifocal IOL. Only one eye of each patient was enrolled. Eyes were devided into three groups according the axial length (AL), including the short AL group, the control group and the long AL group. Manifest refraction, uncorrected and distance-corrected visual acuity at different distances, contrast sensitivity, aberrations and IOL decentration were measured three months after surgery. Spectacle independence, adverse photic phenomena, overall satisfaction and life quality were assessed with a questionnaire.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| the short AL group | Eyes with AL less than 22.50 mm were devided into the short AL group. |
| |
| the control group | Eyes with AL between 22.50 to 25.50 mm were devided into the control group. |
| |
| the long AL group | Eyes with AL more than 25.50 mm were devided into the long AL group. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| AT LISA tri 839MP (Carl Zeiss Meditec AG) | Other | This prospective cohort study collected data of patients who underwent bilateral or unilateral cataract surgery with the AT LISA tri 839MP implantation. |
| Measure | Description | Time Frame |
|---|---|---|
| Refractive Outcomes | Manifest refraction was measured. | Three months after surgery. |
| Visual Acuity at Different Distances | Uncorrected and corrected distance (5 m) visual acuity (UDVA, CDVA), uncorrected and distance-corrected intermediate (80 cm) and near (40 cm) visual acuity (UIVA, DCIVA, UNVA and DCNVA) were measured. | Three months after surgery. |
| Defocus Curve | The defocus curve was measured with the additional spherical diopters from +2.00 D to -4.00 D in 0.50 D steps. | Three months after surgery. |
| Contrast Sensitivity and Aberrations | Using the OPTEC 6500 Vision Tester (Stereo Optical Co. Inc, Chicago, USA), the contrast sensitivity was conducted under four conditions, including photopic(85 cd/m2), mesopic(3 cd/m2), photopic with glare and mesopic with glare. Besides, there are five spatial frequencies (1.5, 3, 6, 12, and 18 cycles per degree [cpd]) under every condition. | Three months after surgery. |
| IOL decentration | OPD Scan-III (NIDEK, Inc.) can automatically recognize and locate the edge of the pupil and measure its position relative to the optic axis. After pupil dilation, the IOL decentration was measured through adjusting the edge of the pupil to the edge of the lens manually. | Three months after surgery. |
| Subjective Satisfaction | The subjective satisfaction was assessed by a self-made questionnaire, which evaluated the spectacle independence at different distances, the incidence of several adverse photic phenomena including glare, halo and starburst, and the overall satisfaction. |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
This prospective cohort study collected data of patients who underwent bilateral or unilateral cataract surgery with the AT LISA tri 839MP implantation at the Department of Ophthalmology, Peking University Third Hospital, Beijing, China.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Peking University Third Hospital | Beijing | Beijing Municipality | 100191 | China |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002386 | Cataract |
| D011305 | Presbyopia |
| D009216 | Myopia |
| D010549 | Personal Satisfaction |
| ID | Term |
|---|---|
| D007905 | Lens Diseases |
| D005128 | Eye Diseases |
| D012030 | Refractive Errors |
| D001519 | Behavior |
Not provided
Not provided
Not provided
Not provided
Not provided
| Three months after surgery. |
| Life Quality | The life quality after surgery was assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25) in Chinese. | Three months after surgery. |