This study aims to explore the efficacy and safety of remote ischemia adaptation for the treatment of resistant hypertension.
Resistant hypertension is defined as a blood pressure of 140/90 mmHg or higher despite adherence to at least three antihypertensive drugs (including one diuretic), accounting for 20% to 30% of patients with hypertension. Compared with patients with well-controlled blood pressure, the cardiovascular risk of resistant hypertension is increased by about 50%. Limb remote ischemic conditioning (LRIC) triggers endogenous protective effects through transient and repeated ischemia in the limb to protect remote tissues and organs. The mechanisms of LRIC involve the regulation of the autonomic nervous system, the release of humoral factors, improvement of vascular endothelial function, and modulation of immune/inflammatory responses, which can antagonize the pathogenesis of hypertension through multiple pathways to lead to a drop in BP theoretically. This theory has been preliminarily confirmed by several small sample-size studies in non-resistant hypertension. This study aims to explore the efficacy and safety of remote ischemia adaptation for the treatment of resistant hypertension.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| RIC group | Experimental | RIC is a non-invasive therapy that is performed by automated pneumatic cuffs placed on bilateral arms. The RIC protocol includes five cycles of 5-min inflation to 200mmHg and 5-min deflation. |
|
| Sham RIC group | Sham Comparator | The Sham-RIC protocol include five cycles of 5-min inflation to 60 mmHg and 5-min deflation by placing automated pneumatic cuffs on bilateral arms. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| RIC | Device | RIC is a non-invasive therapy that is performed by automated pneumatic cuffs placed on bilateral arms. The RIC protocol includes five cycles of 5-min inflation to 200mmHg and 5-min deflation. |
| Measure | Description | Time Frame |
|---|---|---|
| Changes of 24 h average systolic blood pressure | Changes of 24 h average systolic blood pressure from baseline to 8 weeks | from baseline to 8 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Changes of 24 h average diasolic blood pressure | Changes of 24 h average diasolic blood pressure from baseline to 8 weeks | from baseline to 8 weeks |
| Changes of daytime average systolic blood pressure |
Not provided
Inclusion Criteria:
Aged 30~80 years old;
Taking ≥ 3 antihypertensive drugs (including one diuretic) for more than 4 weeks regularly;
Office blood pressure ≥ 140/90mmhg, and 24 h average blood pressure ≥ 130/80 mmHg;
Exclusion Criteria:
Secondary hypertension;
eGFR<45ml/min/1.73m2ï¼›
Office blood pressure ≥180/110 mmHg, and 24 h average blood pressure ≥ 170/100 mmHg;
Hypertensive crisis occurred within 3 months;
Type 1 diabetes;
Cardiovascular events occurred within 3 months;
Atrial fibrillation;
Presence of any severe disease that adversely affects the subject or study;
Patients with contraindication for remote ischemic conditioning, such as vascular injury, soft tissue injury, orthopedic injury, or arm infection;
Pregnancy, lactation, or planned pregnancy;
Patients not suitable for this trial considered by researchers for other reasonsï¼›
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Xunming Ji, MD, PhD | Contact | 83199430 | jixm@ccmu.edu.cn | |
| Wenting Guo | Contact | 18368910464 | 18368910464@163.com |
| Name | Affiliation | Role |
|---|---|---|
| Xunming Ji, MD, PhD | Xuanwu Hospital, Beijing | Principal Investigator |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Sham-RIC | Device | The Sham-RIC protocol include five cycles of 5-min inflation to 60 mmHg and 5-min deflation by placing automated pneumatic cuffs on bilateral arms. |
|
Changes of daytime average systolic blood pressure from baseline to 8 weeks
| from baseline to 8 weeks |
| Changes of daytime average diastolic blood pressure | Changes of daytime average diastolic blood pressure from baseline to 8 weeks | from baseline to 8 weeks |
| Changes of nighttime average systolic blood pressure | Changes of nighttime average systolic blood pressure from baseline to 8 weeks | from baseline to 8 weeks |
| Changes of nighttime average diastolic blood pressure | Changes of nighttime average diastolic blood pressure from baseline to 8 weeks | from baseline to 8 weeks |
| Changes of 24 h average heart rate | Changes of 24 h average heart rate from baseline to 8 weeks | from baseline to 8 weeks |
| Changes of office systolic blood pressure | Changes of office systolic blood pressure from baseline to 8 weeks | from baseline to 8 weeks |
| Changes of office diastolic blood pressure | Changes of office diastolic blood pressure from baseline to 8 weeks | from baseline to 8 weeks |
| Changes of home systolic blood pressure | Changes of home systolic blood pressure from baseline to 8 weeks | from baseline to 8 weeks |
| Changes of home diastolic blood pressure | Changes of home diastolic blood pressure from baseline to 8 weeks | from baseline to 8 weeks |