The aim of this study was to evaluate the efficacy and safety of renal stents implanted in ectatic/aneurysmatic coronary arteries.
In total, 18 patients (renal stent group) who underwent renal stent implantation in ectatic/aneurysmatic coronary arteries requiring percutaneous coronary intervention (PCI) and 45 patients who underwent large-sized bare metal coronary stent (BMCS) implantation (BMCS group) at our centre between 2015 and 2020 were included in the study. Control coronary angiography (CAG) was performed during the follow-up of these patients, and angiography-guided quantitative measurements were performed during PCI. The primary endpoints were myocardial infarction and cardiovascular mortality, and the secondary endpoints were restenosis and all-cause mortality.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| renal stent group | Experimental | Acute coronary patients treatment with renal stent |
|
| BMCS group | Active Comparator | Acute coronary patients treatment with bare-metal stent |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Renal stent | Drug | renal stent implantation in ectatic/aneurysmatic coronary arteries |
|
| Measure | Description | Time Frame |
|---|---|---|
| primary endpoints | Rate of myocardial infarction and cardiovascular mortality | 2 year |
| Measure | Description | Time Frame |
|---|---|---|
| secondary endpoints | Rate of restenosis and all-cause mortality | 2 year |
Not provided
Inclusion Criteria:
Acute coronary syndrome patients
ectatic/aneurysmatic coronary arteries
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 38299468 | Derived | Camci S, Ari H, Sunbul A, Ari S, Melek M, Bozat T. Safety and efficacy results of percutaneous renal stent implantation in patients with acute coronary syndrome with ectatic and aneurysmatic coronary arteries. Postgrad Med. 2024 Jan;136(1):95-102. doi: 10.1080/00325481.2024.2313447. Epub 2024 Feb 5. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003323 | Coronary Aneurysm |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| D000783 |
| Aneurysm |
| D014652 | Vascular Diseases |