The aim of this study is to investigate if the use of artificial intelligence (AI) in colonoscopy improves the polyp detection rate, and if the use of AI has a learning effect.
The endoscopists will use GI Genius from Medtronic, a device that uses artificial intelligence (AI) based on machine learning to detect polyps in the colon in real time during colonoscopy. The device interprets the endoscopy pictures and superimposes possible polyps with frames.
The patients will be included in regular outpatient clinics in Western Norway. The endoscopists will be divided into groups depending on their experience. The endoscopists will perform colonoscopies in three phases; (1) before the use of AI, (2) during the use of AI and (3) after the use of AI. The investigators will then evaluate the polyp detection rate (PDR) in the three phases to see if AI increases PDR, and if there is a learning effect on PDR after the use of AI. The investigators will also evaluate if there is a difference in the learning-effect from AI-use depending on if the endoscopist is experienced or inexperienced.
The PDR's are registered as part of Norway's national quality register of colonoscopy, Gastronet. The data registered in Gastronet can also help the investigators evaluate other outcomes such as withdrawal time, bowel preparation, patient reported pain, patient satisfaction and complications.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| With artificial intelligence (AI) | Active Comparator | Use of GI Genius artificial intelligence device during colonoscopy. |
|
| Without artificial intelligence | Active Comparator | Use of standard colonoscopy equipment without GI Genius. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| GI Genius | Device | The use of artificial intelligence during colonoscopy to improve polyp detection. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Polyp detection rate (PDR) with and without artificial intelligence (AI) | Evaluate the PDR with and without the use of GI Genus artificial intelligence | 18 months |
| PDR after the use of AI, is there a learning effect? | Evaluate if there is an improved PDR after the use of AI | 18 months |
| Measure | Description | Time Frame |
|---|---|---|
| Withdrawal time | To evaluate if the withdrawal time is influenced by the use of artificial intelligence | 18 months |
| Complications | To evaluate if there are more registered complications with the use of AI |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Roald F. Havre, Professor | Helse Bergen | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Haraldsplass Deaconess Hospital | Bergen | Vestland | 5009 | Norway | ||
| Haukeland University Hospital |
Not provided
| Label | URL |
|---|---|
| Gastronet, the national quality register of colonoscopies | View source |
Not provided
There is no specific plan to share IPD with other researchers.
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003111 | Colonic Polyps |
| ID | Term |
|---|---|
| D007417 | Intestinal Polyps |
| D011127 | Polyps |
| D020763 | Pathological Conditions, Anatomical |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Endoscopists will perform colonoscopies in three consecutive phases; 1. without artificial intelligence (AI), 2. with AI, 3. without (AI).
Not provided
Not provided
Not provided
Not provided
| Standard white light colonoscope | Device | Standard colonoscopy. |
|
| 24 months |
| Bergen |
| Vestland |
| 5021 |
| Norway |