This study is a study that qualifies as "other clinical investigation" under Art. 82 MDR and §47 Abs. 3 MPDG with a CE-marked device that aims to demonstrate that the physiological signals from the Onera STS system are substantially equivalent to physiological systems recorded by traditional PSG systems. Furthermore, the study aims to identify the proportion of users who can successfully perform an overnight Onera STS study in an unsupervised home setting. The Onera STS will be used within its approved indication, and the study participants will not be subjected to additional invasive or burdensome procedures.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Validation Study of a patch-based PSG system | Experimental | Measuring and recording multiple physiological parameters from a patient which are used by clinicians to make a decision on the diagnosis of sleep. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Polysomnography | Diagnostic Test | Measuring and recording multiple physiological parameters from a patient which are used by clinicians to make a decision on the diagnosis of sleep. |
| Measure | Description | Time Frame |
|---|---|---|
| EOG left | Electrooculogram (EOG) is measured on the left side. Here, electrical activity of the eye is measured with an electrode and expressed in microvolt[uV]. | 1 year |
| EOG right | Electrooculogram (EOG) is measured on the right side. Here, electrical activity of the eye is measured with an electrode and expressed in microvolt[uV]. | 1 year |
| EEG left | Electroencephalogram (EEG) is measured on the left side. Here, electrical activity of the brain is measured with an electrode and expressed in microvolt[uV]. | 1 year |
| EEG right | Electroencephalogram (EEG) is measured on the right side. Here, electrical activity of the brain is measured with an electrode and expressed in microvolt[uV]. | 1 year |
| EMG left | Electromyogram (EMG) is measured on the left side. Here, electrical activity of the muscle is measured with an electrode and expressed in microvolt[uV]. | 1 year |
| EMG right | Electromyogram (EMG) is measured on the right side. Here, electrical activity of the muscle is measured with an electrode and expressed in microvolt[uV]. | 1 year |
| SpO2 | Oxygen Saturation (SpO2) is derived from red and infrared Photoplethysmography (PPG) which is measured on the forehead with a reflective pulse oximetry sensor. |
| Measure | Description | Time Frame |
|---|---|---|
| Total Sleep Time | The total time spend asleep expressed in minutes or hours. | 1 year |
| Time In Bed | The total time spend in bed expressed in minutes or hours. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Hartmut Schneider | Principal Investigator | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| American Sleep Clinic | Frankfurt | Frankfurt Am Main | 60389 | Germany | ||
| Schlaf- u. Beatmungszentrum Ulm/Blaubeuren |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 39773950 | Derived | Viniol C, Galetke W, Woehrle H, Nilius G, Schobel C, Randerath W, Leiter J, Canisius S, Schneider H. Clinical validation of a wireless patch-based polysomnography system. J Clin Sleep Med. 2025 May 1;21(5):813-823. doi: 10.5664/jcsm.11524. |
Not provided
Not provided
Pseudonymized datasets and 2D images will be shared with Onera for analysis using secure data transfer. Any images of the facial region will have distinguishing features redacted prior to transfer. Pseudonymized PSG and Onera STS studies (raw and scored) will also be shared with Onera. Following transfer, all study data will be stored on a password protected computer and will only be made available to Onera employees who plan to process it in a way that is compatible with the purposes for which it was collected.
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D012893 | Sleep Wake Disorders |
| ID | Term |
|---|---|
| D009422 | Nervous System Diseases |
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D017286 | Polysomnography |
| ID | Term |
|---|---|
| D008991 | Monitoring, Physiologic |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 1 year |
| ECG | Electrocardiogram (ECG) is measured on the chest. Here, electrical activity of the heart is measured with an electrode and expressed in microvolt[mV]. | 1 year |
| BioZ Flow | Respiratory Flow (BioZ Flow) is derived from the bioimpedance which is measured on the chest with an electrode (expressed: [a.u.]). | 1 year |
| BioZ Effort | Respiratory Effort (BioZ Effort) is derived from the bioimpedance which is measured on the chest with an electrode (expressed: [a.u.]). | 1 year |
| Activity | The activity is derived from the accelerometer data of the x, y, and z axis, which is measured on the chest and expressed in the gravitational force equivalent[g]. | 1 year |
| Snoring | Snoring is measured with the microphone imbedded in the sensor on the chest and expressed in Decibel[dB]. | 1 year |
| Body Position | The body Position is derived from the accelerometer data of the x, y, and z axis, which is measured on the chest and expressed in degrees[deg]. | 1 year |
| Nasal Cannula Flow | The Nasal Cannula Flow is measured on the belly using a cannula (expressed: [mmH2O]). | 1 year |
| EMG Leg | Electromyogram (EMG) is measured on the lower leg. Here, electrical activity of the muscle is measured with an electrode and expressed in microvolt[mV]. | 1 year |
| 1 year |
| SOL | Sleep Onset Latency (SOL) is the length of time that it takes to accomplish the transition from full wakefulness to sleep, expressed in minutes or hours. | 1 year |
| Wake Time | The total time spend awake expressed in minutes or hours. | 1 year |
| Time in N1 | The total time spend in the N1 sleep stage, expressed in minutes or hours. | 1 year |
| Time in N2 | The total time spend in the N2 sleep stage, expressed in minutes or hours. | 1 year |
| Time in N3 | The total time spend in the N3 sleep stage, expressed in minutes or hours. | 1 year |
| Time in REM | The total time spend in the Rapid Eye Movement (REM) sleep stage, expressed in minutes or hours. | 1 year |
| Time in NREM | The total time spend in the Non Rapid Eye Movement (NREM), which contains of the N1, N2, N3 sleep stages, expressed in minutes or hours. | 1 year |
| REM | Amount of time spend in the Rapid Eye Movement (REM) sleep stage, expressed in percentage [%]. | 1 year |
| NREM | Amount of time spend in the Non Rapid Eye Movement (NREM) sleep stage, expressed in percentage [%]. | 1 year |
| REM Onset Latency | The elapsed time between sleep onset and the onset of the first Rapid Eye Movement (REM) sleep period, expressed in minutes or hours. | 1 year |
| WASO | Wake After Sleep Onset (WASO) measures wakefulness, excluding the wakefulness occurring before sleep onset, and is expressed in minutes or hours. | 1 year |
| AI | The Arousal Index (AI) divides the total number of arousals by the number of hours of sleep, and therefore is an index for the sleep quality. The lower this amount, the better the outcome. | 1 year |
| AHI | The Apnea Hypopnea Index (AHI) is the total amount of apnea or hypopnea event per hour of sleep, and therefore is an index for the severity of sleep apnea. The lower this amount, the better the outcome. | 1 year |
| SpO2 | Oxygen Saturation (SpO2) is derived from red and infrared Photoplethysmography (PPG) which is measured on the forehead with a reflective pulse oximetry sensor. This will be expressed in the mean, the minimum, and the maximum. | 1 year |
| ODI | The Oxygen Desaturation Index (ODI) is the amount of times per hour of sleep that your blood oxygen level drops by 3% from baseline. The lower this amount the better the outcome. | 1 year |
| HR | Heart Rate (HR) is the number of times the heart beats per minute, is derived from the Electrocardiogram (ECG), and expressed in beats per minute[bpm]. | 1 year |
| Set-up Time PSG (not applicable for application in unsupervised home setting) | Comparison of the setup time (fitting and activation) between the Onera STS system and a traditional Polysomnography (PSG) system. | 1 year |
| Blaubeuren Abbey |
| 89143 |
| Germany |
| Ruhrlandklinik, Zentrum für Schlaf- und Telemedizin | Essen | 45239 | Germany |
| Evang. Kliniken Essen-Mitte | Essen | 45276 | Germany |
| VAMED Klinik Hagen-Ambrock | Hagen | 58091 | Germany |
| Universitätsklinikum Giessen und Marburg | Marburg | 35043 | Germany |
| Krankenhaus Bethanien | Solingen | 42699 | Germany |
| D001523 | Mental Disorders |