Our study is aimed to evaluate the effect of 3D printing assistive device on hand function for patients with neural injury.
Background: Injury to the central or peripheral nerves can lead to limited hand function and further affect the ability of daily life. The use of assistive devices can assist functional activities and reduce the phenomenon of non-use. 3D printing technology was used to construct personalized, complicated orthosis, and one piece to reduce assembly time. But the evidence most are product development, but few of study investigate the effectiveness and it cannot be widely used for hand injuries.
Aim: To evaluate the effect of 3D printing assistive device on hand function for patients with neural injury.
Methods: Thirty neural injury patients were recruited and randomized into experimental (3D printing assistive device) or control (universal cuff) groups for 4 weeks of treatment (thirty minutes a time, twice a week). The performance was assessed by a blinded assessor included Active Range of motion (AROM), Box and block test, Grip dynamometer, upper extremity task, Disability of the arm, shoulder and hand questionnaire(DASH), General Health Questionnaire(GHQ-12) and Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST). The practice performance and adverse effect were recorded. Collected data will be analyzed with nonparametric tests by SPSS version 20.0, and alpha level was set at .05.
Keywords: Neural injury, 3D printing, assistive device, hand function.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 3D printing assistive device group | Experimental | experimental (3D printing assistive device) groups for 4 weeks of treatment (thirty minutes a time, twice a week). |
|
| universal cuff groups | Active Comparator | control (universal cuff) groups for 4 weeks of treatment (thirty minutes a time, twice a week). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Wear 3D printing assistive device | Behavioral | Wear 3D printing aids and engage in functional tasks, including eating, typing, and writing. At home: use daily, 30 minutes each time; Treatment room: 30 minutes twice a week |
| Measure | Description | Time Frame |
|---|---|---|
| Active joint range of motion of shoulder and elbow | use a goniometer to measure the active joint movements of the shoulder and elbow, including shoulder flexion, abduction, external rotation , internal rotation, and elbow flexion angle. | Change from Baseline at 2 weeks and 4 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Box and block test (BBT) | Assess grasping, transporting, and releasing small blocks, and count the number of blocks the individual moves 1 inch to the opposite side of the box in one minute. | Change from Baseline at 2 weeks and 4 weeks |
| Grip power |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Hsinchieh Lee, master | Taipei Medical University Shuang Ho Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Taipei Medical University Shuang Ho Hospital | New Taipei City | Taiwan |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 29185087 | Background | Amaral DS, Duarte ALBP, Barros SS, Cavalcanti SV, Ranzolin A, Leite VMM, Dantas AT, Oliveira ASCRC, Santos PS, Silva JCA, Marques CDL. Assistive devices: an effective strategy in non-pharmacological treatment for hand osteoarthritis-randomized clinical trial. Rheumatol Int. 2018 Mar;38(3):343-351. doi: 10.1007/s00296-017-3892-1. Epub 2017 Nov 28. | |
| 27552260 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Wear universal cuff device | Behavioral | Wear universal cuff aids and engage in functional tasks, including eating, typing, and writing. At home: use daily, 30 minutes each time; Treatment room: 30 minutes twice a week |
|
use the Jamar Dynamometer (Asimow Engineering Co., CA, USA) grip strength device to test, ask the individual to bend the elbow and shoulder adduct, and hold the grip strength device firmly, and measure the average 3 times in total
| Change from Baseline at 2 weeks and 4 weeks |
| Hand function tasks | Complete the tasks of writing, spoon, and typing. The writing task is based on the writing sub-item of the Basic Literacy Test, and the individual is asked to write a short sentence, the content is 25 words, count the number of words in two minute; spoon task, ask the client to use a spoon to scoop five kidney beans into a can, and count the seconds it takes; one-minute typing test (https://typing.tw/), to see the number of words typed in one minute with the correct rate. | Change from Baseline at 2 weeks and 4 weeks |
| Disabilities of the Arm, Shoulder and Hand Questionnaire (DASH) | The first and second subscales are used. To evaluate the ability of a patient to perform certain upper extremity activities. This questionnaire is a self-report questionnaire that patients can rate difficulty and interference with daily life on a 5 point Likert scale., which are converted into 100 points. The higher the score, the higher the severity. | Change from Baseline at 4 weeks |
| General Health Questionnaire (GHQ-12) | Self-rating scale used to measure mental health status. Respondents rated the frequency of occurrence of each item in the past month on a scale of 0 (not at all) to 3 (often). The total score can be up to 36 points, and a score of 15 or more can be defined as mental distress. The higher the score, the more serious the distress. | Change from Baseline at 4 weeks |
| Daily wearing activity record sheet | To record the daily wearing and practice time, the number of side effects, such as soreness, pain, injury, etc. | Every training session during 8 sessions, total sessions continued to 4 weeks |
| Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST) | The questionnaire is a subjective self-administered scale for the use of assistive devices, with a 5-point scale (strongly agree to strongly disagree), including beauty, complexity, weight , resistance, comfort, easy to wear, etc. | The end of the study at 4 weeks |
| Armour BS, Courtney-Long EA, Fox MH, Fredine H, Cahill A. Prevalence and Causes of Paralysis-United States, 2013. Am J Public Health. 2016 Oct;106(10):1855-7. doi: 10.2105/AJPH.2016.303270. Epub 2016 Aug 23. |
| 27594781 | Background | Baronio G, Harran S, Signoroni A. A Critical Analysis of a Hand Orthosis Reverse Engineering and 3D Printing Process. Appl Bionics Biomech. 2016;2016:8347478. doi: 10.1155/2016/8347478. Epub 2016 Aug 9. |
| 25012864 | Background | Basteris A, Nijenhuis SM, Stienen AH, Buurke JH, Prange GB, Amirabdollahian F. Training modalities in robot-mediated upper limb rehabilitation in stroke: a framework for classification based on a systematic review. J Neuroeng Rehabil. 2014 Jul 10;11:111. doi: 10.1186/1743-0003-11-111. |
| 26522902 | Background | Bethoux F. Spasticity Management After Stroke. Phys Med Rehabil Clin N Am. 2015 Nov;26(4):625-39. doi: 10.1016/j.pmr.2015.07.003. Epub 2015 Sep 26. |
| Background | Cazon, A., Aizpurua, J., Paterson, A., Bibb, R., Campbell, R. I. J. V., & Prototyping, P. (2014). Customised design and manufacture of protective face masks combining a practitioner-friendly modelling approach and low-cost devices for digitising and additive manufacturing: This paper analyses the viability of replacing conventional practice with AM method to make customized protective face masks. 9(4), 251-261. |
| 32311991 | Background | Chae DS, Kim DH, Kang KY, Kim DY, Park SW, Park SJ, Kim JH. The functional effect of 3D-printing individualized orthosis for patients with peripheral nerve injuries: Three case reports. Medicine (Baltimore). 2020 Apr;99(16):e19791. doi: 10.1097/MD.0000000000019791. |
| 19261767 | Background | Chen HM, Chen CC, Hsueh IP, Huang SL, Hsieh CL. Test-retest reproducibility and smallest real difference of 5 hand function tests in patients with stroke. Neurorehabil Neural Repair. 2009 Jun;23(5):435-40. doi: 10.1177/1545968308331146. Epub 2009 Mar 4. |
| 18940092 | Background | Sanchez-Lopez Mdel P, Dresch V. The 12-Item General Health Questionnaire (GHQ-12): reliability, external validity and factor structure in the Spanish population. Psicothema. 2008 Nov;20(4):839-43. |
| 28649911 | Background | Diment LE, Thompson MS, Bergmann JH. Three-dimensional printed upper-limb prostheses lack randomised controlled trials: A systematic review. Prosthet Orthot Int. 2018 Feb;42(1):7-13. doi: 10.1177/0309364617704803. Epub 2017 Jun 24. |
| Background | Fitzpatrick, A. P., Mohanned, M. I., Collins, P. K., & Gibson, I. (2017). Design of a patient specific, 3D printed arm cast. KnE Engineering, 135-142. |
| 30740805 | Background | Funch A, Kruse NB, la Cour K, Peoples H, Waehrens EE, Brandt A. The association between having assistive devices and activities of daily living ability and health-related quality of life: An exploratory cross-sectional study among people with advanced cancer. Eur J Cancer Care (Engl). 2019 May;28(3):e13002. doi: 10.1111/ecc.13002. Epub 2019 Feb 10. |
| 11478185 | Background | Gerhardt JJ, Rondinelli RD. Goniometric techniques for range-of-motion assessment. Phys Med Rehabil Clin N Am. 2001 Aug;12(3):507-27. |
| 18796752 | Background | Hamilton GF, McDonald C, Chenier TC. Measurement of grip strength: validity and reliability of the sphygmomanometer and jamar grip dynamometer. J Orthop Sports Phys Ther. 1992;16(5):215-9. doi: 10.2519/jospt.1992.16.5.215. |
| Background | Harman, D., & Craigie, S. J. E. G. M. (2011). Gerotechnology series: Toileting aids. 2(5), 314-318. |
| Background | Hepherd, R. J. E. G. M. (2011). Aids for bathing and showering. 2(3), 190-193. |
| Background | Hunzeker, M., & Ozelie, R. (2021). A Cost-Effective Analysis of 3D Printing Applications in Occupational Therapy Practice. The Open Journal of Occupational Therapy, 9(1), 1-12. |
| 32423845 | Background | Janson R, Burkhart K, Firchau C, Hicks K, Pittman M, Yopps M, Hatfield S, Garabrant A. Three-dimensional printed assistive devices for addressing occupational performance issues of the hand: A case report. J Hand Ther. 2020 Apr-Jun;33(2):164-169. doi: 10.1016/j.jht.2020.03.025. Epub 2020 May 16. |
| Background | Jumani, M., Shaikh, S., & Shah, S. A. J. S. I. (2014). RAPID MANUFACTURING TECHNIQUE FOR FABRICATION OF CUSTOM-MADE FOOT ORTHOSES. 26(1). |
| 33855068 | Background | Keller M, Guebeli A, Thieringer F, Honigmann P. Overview of In-Hospital 3D Printing and Practical Applications in Hand Surgery. Biomed Res Int. 2021 Mar 26;2021:4650245. doi: 10.1155/2021/4650245. eCollection 2021. |
| 30318956 | Background | Lee KH, Kim DK, Cha YH, Kwon JY, Kim DH, Kim SJ. Personalized assistive device manufactured by 3D modelling and printing techniques. Disabil Rehabil Assist Technol. 2019 Jul;14(5):526-531. doi: 10.1080/17483107.2018.1494217. Epub 2018 Oct 14. |
| 15490028 | Background | Liang HW, Wang HK, Yao G, Horng YS, Hou SM. Psychometric evaluation of the Taiwan version of the Disability of the Arm, Shoulder, and Hand (DASH) questionnaire. J Formos Med Assoc. 2004 Oct;103(10):773-9. |
| 17569392 | Background | Long TM, Woolverton M, Perry DF, Thomas MJ. Training needs of pediatric occupational therapists in assistive technology. Am J Occup Ther. 2007 May-Jun;61(3):345-54. doi: 10.5014/ajot.61.3.345. |
| Background | Lubbes, E. (2016). Investigation and Assessment of Upper-Limb Prosthetic Care and Business Model Design for 3D-Printed Prostheses in the Netherlands. |
| 19906764 | Background | Ma HI, Hwang WJ, Tsai PL, Hsu YW. The effect of eating utensil weight on functional arm movement in people with Parkinson's disease: a controlled clinical trial. Clin Rehabil. 2009 Dec;23(12):1086-92. doi: 10.1177/0269215509342334. |
| 25282582 | Background | Marque P, Gasq D, Castel-Lacanal E, De Boissezon X, Loubinoux I. Post-stroke hemiplegia rehabilitation: evolution of the concepts. Ann Phys Rehabil Med. 2014 Nov;57(8):520-529. doi: 10.1016/j.rehab.2014.08.004. Epub 2014 Aug 23. |
| Background | Martin, L. M. J. A. J. o. O. T. (1988). Clinical Mechanics of the Hand. 42(3), 199-199. |
| 26893960 | Background | McDonald SS, Levine D, Richards J, Aguilar L. Effectiveness of adaptive silverware on range of motion of the hand. PeerJ. 2016 Feb 15;4:e1667. doi: 10.7717/peerj.1667. eCollection 2016. |
| 30180536 | Background | Nam HS, Seo CH, Joo SY, Kim DH, Park DS. The Application of Three-Dimensional Printed Finger Splints for Post Hand Burn Patients: A Case Series Investigation. Ann Rehabil Med. 2018 Aug;42(4):634-638. doi: 10.5535/arm.2018.42.4.634. Epub 2018 Aug 31. |
| 25217124 | Background | Nordin N, Xie SQ, Wunsche B. Assessment of movement quality in robot- assisted upper limb rehabilitation after stroke: a review. J Neuroeng Rehabil. 2014 Sep 12;11:137. doi: 10.1186/1743-0003-11-137. |
| Background | Phillips, B., Zingalis, G., Ritter, S., & Mehta, K. (2015). A review of current upper-limb prostheses for resource constrained settings. Paper presented at the 2015 IEEE global humanitarian technology conference (GHTC). |
| 29470557 | Background | Portnova AA, Mukherjee G, Peters KM, Yamane A, Steele KM. Design of a 3D-printed, open-source wrist-driven orthosis for individuals with spinal cord injury. PLoS One. 2018 Feb 22;13(2):e0193106. doi: 10.1371/journal.pone.0193106. eCollection 2018. |
| Background | Radomski, M. V., & Latham, C. A. T. (2014). Occupational therapy for physical dysfunction(7 th ed): Lippincott Williams & Wilkins. |
| 31608177 | Background | Roda-Sales A, Vergara M, Sancho-Bru JL, Gracia-Ibanez V, Jarque-Bou NJ. Effect on hand kinematics when using assistive devices during activities of daily living. PeerJ. 2019 Oct 8;7:e7806. doi: 10.7717/peerj.7806. eCollection 2019. |
| 30981658 | Background | Sari MI, Sahin I, Gokce H, Oksuz C. Ring orthosis design and production by rapid prototyping approach. J Hand Ther. 2020 Apr-Jun;33(2):170-173. doi: 10.1016/j.jht.2019.02.003. Epub 2019 Apr 10. |
| Background | Saunders, R., Astifidis, R., Burke, S. L., CHT, M., Higgins, J., & McClinton, M. A. (2015). Hand and upper extremity rehabilitation: a practical guide: Elsevier Health Sciences. |
| 21534712 | Background | Skymne C, Dahlin-Ivanoff S, Claesson L, Eklund K. Getting used to assistive devices: ambivalent experiences by frail elderly persons. Scand J Occup Ther. 2012 Mar;19(2):194-203. doi: 10.3109/11038128.2011.569757. Epub 2011 May 2. |
| Background | Somers, M. F. (2001). Spinal cord injury: functional rehabilitation: Prentice Hall. |
| Background | Stowe, S., Hopes, J., & Mulley, G. J. E. g. m. (2010). Gerotechnology series: 2. Walking aids. 1(2), 122-127. |
| Background | Takla, M. K., Mahmoud, E. A., & Abd El-Latif, N. J. B. o. F. o. P. T. (2018). Jebsen Taylor Hand Function test: Gender, dominance, and age differences in healthy Egyptian population. 23(2), 85-93. |
| 23885710 | Background | Thibaut A, Chatelle C, Ziegler E, Bruno MA, Laureys S, Gosseries O. Spasticity after stroke: physiology, assessment and treatment. Brain Inj. 2013;27(10):1093-105. doi: 10.3109/02699052.2013.804202. Epub 2013 Jul 25. |
| Background | Toth, L., Schiffer, A., Nyitrai, M., Pentek, A., Told, R., & Maroti, P. (2020). Developing an anti-spastic orthosis for daily home-use of stroke patients using smart memory alloys and 3D printing technologies. Materials & Design, 195, 109029. |
| 31888695 | Background | Yoo HJ, Lee S, Kim J, Park C, Lee B. Development of 3D-printed myoelectric hand orthosis for patients with spinal cord injury. J Neuroeng Rehabil. 2019 Dec 30;16(1):162. doi: 10.1186/s12984-019-0633-6. |