Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Epidural analgesia for relief of labor pain is a very common, safe and reliable technique that requires placement of a catheter in the epidural space. About 5% of labor epidural catheters may need to be re-sited due to failure of analgesia. This is often caused by malposition of the epidural catheter. Many factors may influence the position of the tip of the epidural catheter and the resulting spread of local anesthetic solution within the epidural space and consequently the quality of labor pain management. The electrical stimulation of the epidural catheter, commonly known as Tsui test, can reliably confirm its positioning within the epidural space if this stimulus produces a muscular twitch under a certain current amplitude threshold. This muscular response is unilateral in 90% of the cases, not having any relationship between unilaterality and unsatisfactory catheter performance. It is unknown if this unilateral response has any correlation with the actual position of the catheter tip in terms of right or left side of the epidural space. Furthermore, the Tsui test does not give any information on the spread of anesthetic solution into the epidural space. Recent investigation shows that color flow doppler ultrasound during fluid injection through the epidural catheter may be helpful in determining the laterality of the tip of the epidural catheter; furthermore it may be able to inform about the spread the anesthetic solution, which is a limitation of the Tsui test. The investigators will perform an observational study to investigate the response patterns of Tsui test and Color flow Doppler ultrasound in the obstetric population. Women who have delivered under epidural analgesia will be approached for the study before the epidural catheter is removed. The investigators aim to characterize the laterality and current thresholds of Tsui test response and the laterality of the lumbar epidural catheter tip by color doppler ultrasound. The investigators hope to describe the findings and to correlate them with other clinical outcomes.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients who had an epidural placed for labour | Patients who had an epidural placed for labour may take part. Study procedures will take place after delivery and prior to removal of the epidural catheter. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Doppler ultrasonography | Device | color flow Doppler ultrasonography |
|
| Measure | Description | Time Frame |
|---|---|---|
| Tsui test motor response: questionnaire | Tsui test motor response will be recorded as either: left, right or bilateral | 5 minutes |
| Colour flow Doppler ultrasound assessment: questionnaire | Colour flow Doppler ultrasound assessment will be recorded as either: left, right or bilateral | 5 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| Tsui test current threshold amplitude | Epidural catheter stimulation will be performed in all patients with a 0.2 msec pulse width and 1 Hz frequency. The current will be increased from 0 mA until a motor response is observed or until the maximum current of 20 mA is reached. | 5 minutes |
| Tsui test motor response dermatome: abdomen, thigh, leg, feet |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Women who have delivered vaginally under epidural analgesia will be approached for the study before the epidural catheter is removed.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jose CA Carvalho, MD | MOUNT SINAI HOSPITAL | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mount Sinai Hospital | Toronto | Ontario | M5G1X5 | Canada |
Not provided
| ID | Term |
|---|---|
| D048949 | Labor Pain |
| ID | Term |
|---|---|
| D010146 | Pain |
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D018608 | Ultrasonography, Doppler |
| ID | Term |
|---|---|
| D014463 | Ultrasonography |
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
| Tsui test | Device | The stimulator is set at frequency of 1Hz with 0.2 msec pulse width and the current output ranging from 0 to 20 mA. The current output will be carefully increased from zero until motor activity is detected up to a maximum of 20 mA. |
|
The muscle group involved in the response will be documented as: abdomen, thigh, leg, feet. Whether right, left or bilateral will also be recorded. |
| 5 minutes |
| Location of epidural catheter tip flow as detected by Doppler | Location (interspace) of epidural catheter tip flow as detected by Doppler. | 5 minutes |
| Need for catheter mobilization: questionnaire | The need for catheter mobilization, including replacement (at any time after it is placed) will be documented as yes or no. | 12 hours |
| Presence of asymmetric block: questionnaire | The presence of asymmetric block (>=2 segments difference) will be documented as yes or no. | 12 hours |