| Name | Class |
|---|---|
| Dentsply Sirona Implants and Consumables | INDUSTRY |
Not provided
Not provided
Not provided
A 510k approved dental device for subjects requiring single or multiple tooth replacement with implants where immediate restoration/loading is preferred.
The rationale for this study is to provide scientific data on the clinical performance and patient reported outcomes of the PrimeTaper EV implant when utilizing non-guided vs guided surgical technique. The PrimeTaper EV implant has the OsseoSpeed surface, which is especially indicated for use in soft bone applications where implants with other surface treatments may be less effective.
The main interests of this study are to assess the survival and the success rates of the implants supporting maxillary or mandibular fixed single or 2-fixture restorations after 1, 2, 3, 4 and 5 years in function
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Single Arm | Other | There are no arms in the study, it is a non randomized, controlled study |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| PrimeTaper EV | Device | The PrimeTaper EV Implant is a screw shaped dental implant with a defined surface achieved through grit blasting, followed by a process involving a treatment in diluted hydrofluoric acid. There is a conical connection between the implants and the abutments for a tight and stable connection. |
| Measure | Description | Time Frame |
|---|---|---|
| To evaluate implant survival rate at 1 year after final restoration attachment (screw retained when feasible) with single and multiple (fixed bridges) PrimeTaper EV implant(s) utilizing non-guided versus guided surgery | Number of remaining implants counted clinically and radiographically, i.e. 'Yes' or 'No' for each implant where 'Yes' means that the implant is still remaining and 'No' means that the implant is not remaining. | 1 year after final restoration |
| Measure | Description | Time Frame |
|---|---|---|
| Implant stability by manual clinical examination | Mobility (manual stability) will be assessed by a percussion test for resonance indicative of bone to implant contact vertically and laterally. | throughout study, up to the 5 year follow up |
| Implant survival rate |
Not provided
Inclusion Criteria:
Complete denture Partial removable denture Fixed bridges and/or crowns Natural dentition
Exclusion Criteria:
Any of the following is regarded as a criterion for exclusion from the study (all criteria apply at study inclusion, but criteria numbered 1-4 also apply during the entire study period):
Unlikely to be able to comply with study procedures, according to the Investigator's judgment.
Subject is not willing to participate in the study or not able to understand the content of the study.
Involved in the planning and conduct of the study.
Unable or unwilling to return for follow-up visits for a period of 5 years.
Has an uncontrolled pathological process in the oral cavity (e.g. untreated periodontal disease, uncontrolled caries, severe malocclusion, etc.).
Known or suspected current malignancy.
History of radiation therapy in the head and neck region.
History of chemotherapy within 5 years prior to surgery.
Systemic or local disease or condition that could compromise post-operative healing and/or osseointegration (e.g., uncontrolled diabetes mellitus as reported by the subject).
Use of systemic corticosteroids, IV bisphosphonates or any other medication that could compromise post-operative healing and/or osseointegration.
Current alcohol and/or drug abuse.
Smoking more than 10 cigarettes of any type per day.
Current need for major bone grafting and/or augmentation in the planned implant area (esthetic augmentation and minor facial grafting are allowed).
Known pregnancy, or plans to become pregnant during the study period of 5 years
Participation in another clinical study within the previous 6 months that may interfere with the present study.
Post-surgical Exclusion criteria
Insufficient primary stability, as judged by the investigator, of the implant(s).
Severe non-compliance to CIP as judged by the Investigator and/or Dentsply Sirona Implants.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| McClain and Schallhorn Periodontics and Implant Dentistry | Aurora | Colorado | 80012-3260 | United States | ||
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30328194 | Background | Gallucci GO, Hamilton A, Zhou W, Buser D, Chen S. Implant placement and loading protocols in partially edentulous patients: A systematic review. Clin Oral Implants Res. 2018 Oct;29 Suppl 16:106-134. doi: 10.1111/clr.13276. | |
| 5237684 | Background | Loe H. The Gingival Index, the Plaque Index and the Retention Index Systems. J Periodontol. 1967 Nov-Dec;38(6):Suppl:610-6. doi: 10.1902/jop.1967.38.6.610. No abstract available. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Prospective, multicenter, non-randomized, controlled
Not provided
Not provided
Not provided
Not provided
|
Number of remaining implants counted clinically and radiographically, i.e. 'Yes' or 'No' for each implant where 'Yes' means that the implant is still remaining and 'No' means that the implant is not remaining. |
| 2, 3, 4, and 5 years after final restoration attachment |
| Maintenance of marginal bone levels on patient- and implant level. | Changes (mm) in marginal bone level (MBL) | throughout study up to the 5 year follow up visit |
| Condition of the peri-implant mucosa (Plaque Index) | Plaque index will be measured following implant placement by visual inspection using a scoring system of 0-1, 0 being no plaque is present and 1 being plaque is present. | measured at 12 days (no BOP, PPD), 16 weeks, 20 weeks, 6 months, 1,2,3,4,5 years, |
| Condition of the peri-implant mucosa (Recession) | Recession will be measured following implant placement by placing a probe between the tooth and gum to record depth of recession in millimeters from the crown margin to the gingival margin rounded to the nearest 0.5 mm. | measured at 12 days (no BOP, PPD), 16 weeks, 20 weeks, 6 months, 1,2,3,4,5 years, |
| Condition of the peri-implant mucosa (Suppuration by visual inspection). | Suppuration presence or absence will be measured following implant placement by using a scoring system of 0-1. 0 being no suppuration and 1 being suppuration is present. It is being identified by visual inspection and palpitation of moderate inflammation. | measured at 12 days (no BOP, PPD), 16 weeks, 20 weeks, 6 months, 1,2,3,4,5 years, |
| Condition of the peri-implant mucosa. | Keratinized Tissue Width (KTw) will be measures following implant placement | measured at 12 days, 20 weeks, 1,2,3,4,5 years |
| Patient Reported Outcomes (PROs) | subjects will be interviewed to ask about Discomfort using a 0 (no discomfort)-10 (as much discomfort as i have ever felt) point grading system | 20 weeks, 6 months, years 1,2,3,4,5 |
| Patient Reported Outcomes (PROs) | subjects will be interviewed to ask about Esthetics using a 0 (completely displeased)-10 (completely pleased) point grading system | 20 weeks, 6 months, years 1,2,3,4,5 |
| Patient Reported Outcomes (PROs) | subjects will be interviewed to ask about Satisfaction using a 0 (completely dissatisfied) -10 (completely satisfied) point grading system | 20 weeks, 6 months, years 1,2,3,4,5 |
| Investigator Assessment of the Implant-Prosthetic Complex | Evaluation of the Esthetic outcome on a 4 point scale (1=very good, 2= good, 3=acceptable, 4=not acceptable) | 20 weeks and 5 years. |
| Investigator Assessment of the Implant-Prosthetic Complex | Evaluation of Function a 4 point scale (1=very good, 2= good, 3=acceptable, 4=not acceptable) | 20 weeks and 5 years. |
| Investigator Assessment of the Implant-Prosthetic Complex | Evaluation of Gingival Health n a 4 point scale (1=very good, 2= good, 3=acceptable, 4=not acceptable) | 20 weeks and 5 years. |
| Investigator Assessment of the Implant-Prosthetic Complex | Evaluation of Bone Level of the permanent prosthetic restoration n a 4 point scale (1=very good, 2= good, 3=acceptable, 4=not acceptable) | 20 weeks and 5 years. |
| Implant success | Proportion of implants with the derived answer 'No' on the occurrence of "pain", "mobility", "≥2 mm radiological bone loss from initial placement", "infection", "radiolucency" and "6" or greater on the Subject Satisfaction PRO Question and "Very good", "good" or "acceptable" on each Investigator Evaluation of Esthetic Outcome, Function, Gingival Health, Bone Level | throughout study up to the 5 year follow up visit |
| Prosthetic survival | Proportion of original permanent prosthetic restorations still in place at the 5 years after final restoration attachment. | 5 years after final restoration attachment |
| Prosthetic success | Analysis of successful permanent prosthetic restorations (implant-prosthetic complex); Number of suprastructure fractures, technical repairs 5 years after final restoration attachment. | 5 years after final restoration attachment. |
| Colorado Gum Care |
| Broomfield |
| Colorado |
| 80020 |
| United States |
| Periodontal Medicine Surgical Specialists, LLC | Oakbrook Terrace | Illinois | 60181 | United States |
| Metro West Orthodontics & Periodontics | La Vista | Nebraska | 68128 | United States |
| Perio & Implant Associates of Middle TN | Nashville | Tennessee | 37215 | United States |
| Perio Health Professionals | Houston | Texas | 77063-7229 | United States |
| Oral Health Specialists | Tacoma | Washington | 98405-1462 | United States |
| WisNova Institute of Dental Specialists | Kenosha | Wisconsin | 53144-4292 | United States |
| 25030551 | Background | Geraets W, Zhang L, Liu Y, Wismeijer D. Annual bone loss and success rates of dental implants based on radiographic measurements. Dentomaxillofac Radiol. 2014;43(7):20140007. doi: 10.1259/dmfr.20140007. Epub 2014 Jul 17. |
| 18067597 | Result | Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP. A systematic review of the 5-year survival and complication rates of implant-supported single crowns. Clin Oral Implants Res. 2008 Feb;19(2):119-30. doi: 10.1111/j.1600-0501.2007.01453.x. Epub 2007 Dec 7. |
| 30075090 | Result | Elani HW, Starr JR, Da Silva JD, Gallucci GO. Trends in Dental Implant Use in the U.S., 1999-2016, and Projections to 2026. J Dent Res. 2018 Dec;97(13):1424-1430. doi: 10.1177/0022034518792567. Epub 2018 Aug 3. |
| Result | 3. American Dental Association, Patient Smart Dental Implants. Accessed August 15, 2021. |
| 22157097 | Result | Papaspyridakos P, Chen CJ, Singh M, Weber HP, Gallucci GO. Success criteria in implant dentistry: a systematic review. J Dent Res. 2012 Mar;91(3):242-8. doi: 10.1177/0022034511431252. Epub 2011 Dec 8. |
| 22551385 | Result | Kuhl S, Zurcher S, Mahid T, Muller-Gerbl M, Filippi A, Cattin P. Accuracy of full guided vs. half-guided implant surgery. Clin Oral Implants Res. 2013 Jul;24(7):763-9. doi: 10.1111/j.1600-0501.2012.02484.x. Epub 2012 May 3. |
| 29608793 | Result | Younes F, Cosyn J, De Bruyckere T, Cleymaet R, Bouckaert E, Eghbali A. A randomized controlled study on the accuracy of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients. J Clin Periodontol. 2018 Jun;45(6):721-732. doi: 10.1111/jcpe.12897. Epub 2018 May 10. |
| 31958166 | Result | Varga E Jr, Antal M, Major L, Kiscsatari R, Braunitzer G, Piffko J. Guidance means accuracy: A randomized clinical trial on freehand versus guided dental implantation. Clin Oral Implants Res. 2020 May;31(5):417-430. doi: 10.1111/clr.13578. Epub 2020 Jan 31. |
| Result | 8. ITI.org Consensus Statement, Amsterdam 2018. Implant Placement and Loading Protocols |
| 32400121 | Result | Naeini EN, Atashkadeh M, De Bruyn H, D'Haese J. Narrative review regarding the applicability, accuracy, and clinical outcome of flapless implant surgery with or without computer guidance. Clin Implant Dent Relat Res. 2020 Aug;22(4):454-467. doi: 10.1111/cid.12901. Epub 2020 May 13. |
| 30328185 | Result | Sailer I, Strasding M, Valente NA, Zwahlen M, Liu S, Pjetursson BE. A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic multiple-unit fixed dental prostheses. Clin Oral Implants Res. 2018 Oct;29 Suppl 16:184-198. doi: 10.1111/clr.13277. |
| 25951678 | Result | General Assembly of the World Medical Association. World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects. J Am Coll Dent. 2014 Summer;81(3):14-8. |
| Result | 13. ISO. EN ISO 14155. SS-EN ISO 14155:2011: Swedish Standard Institute; 2011 |