Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| British Heart Foundation | OTHER |
Not provided
Not provided
Not provided
Not provided
Not provided
Hypertrophic Obstructive Cardiomyopathy (HOCM) is an inherited cardiac condition which causes the heart muscle to become abnormally thick causing obstruction of blood flow in the heart. This causes debilitating symptoms including shortness of breath, blackouts and chest pain. Current treatments are not ideal as the medication is often poorly tolerated or ineffective.
People with HOCM can often have an Implantable Cardioverter Defibrillator (ICD) to shock them out of dangerous arrhythmias. ICD's can also be used as pacemakers and are a promising treatment option, since they can alter the sequence of the heart muscle contraction thereby relieving the obstruction to the blood flow, making it easier for the heart to pump.
The study will recruit patients who already have an ICD/pacemaker or who are scheduled to have an ICD / pacemaker implanted. For patients who are due to have a device implanted high precision haemodynamic, echocardiographic and electrical measurement techniques will be used to assess whether adjusting the position of the pacing lead (at the time of implant) can bring about changes in LVOT gradient and blood pressure. These patients with a new device and also patients who already have a device in situ will then go on to have atrioventricular delay (AV Delay) optimisation so we can assess what the optimum AV delay should be programmed at in order to bring about the most improvement in LVOT gradient and blood pressure.
Patients will then be recruited into a medium term double blinded randomised crossover study. They will have optimum RV pacing settings turned on for 3 months. They will then return and be crossed over and have optimum RV pacing turned off for a further 3 months. The primary outcome will be to see if optimum RV pacing being turned on is effective in improving symptoms and quality of life.
To test the impact of changing the pacing site and how it affects intra-ventricular delay and the amount of dyssynchrony.
At the time of device implant, the RV lead will be positioned temporarily in the RV apex, low septum, high septum, RV free wall and coronary sinus. Non-invasive blood pressure will be measured by a Finometer device and Echo will assess LVOT gradient whilst pacing is turned on at each site. Ultra-high frequency ECG will be used to assess intraventricular dyssynchrony at each site. Haemodynamic measurements will also be made of aortic pressure and flow using a Combowire (with temporary heparinisation) to assess if non-invasively measured beat-by-beat finometer blood pressure are consistent with invasively measured changes in aortic flow. Combining these measurements will further assess the relationship between level of dyssynchrony, blood pressure and LVOT gradient change. The RV lead will then be implanted in a conventional position.
To use high-precision techniques to assess the impact of adjusting the AV Delay and how it affects blood pressure and LVOT gradient change.
After patients have had their device implanted & those patients who already have a device in situ will then undergo an AV optimisation protocol (paced alternations of AV delay will be made from 40ms in 40ms increments up to 200ms / fusion). Non-invasive blood pressure will be measured (using a Finometer) along with LVOT gradient change with Echo at each AV delay and allow to identify the optimum AV Delay that brings about the most benefit in these acute parameters.
To follow patients over a period of 6 months in a double blinded randomised crossover trial. Patients will have active optimum RV pacing for 3 months. After this point they will then be crossed over for a further 3 months to optimum RV pacing off. Patient and assessor will remain blinded throughout. Patients will have the following assessed at baseline, 3 months and then at 6 months:
Through simulation of a mixed-effects model to analyse the cross-over design, 60 patients would provide approximately 83% power.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Optimum Right Ventricular Pacing On | Active Comparator | AV Delay Optimised RV Pacing. Subjects will remain in this arm for 3 months before being crossed-over. |
|
| Optimum Right Ventricular Pacing Off | No Intervention | Subjects will remain in this arm for 3 months before being crossed-over. The pacemaker will be programmed to minimum ventricular pacing & dynamic AV delay will be programmed off. |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| AV Delay Optimised RV Pacing | Device | AV Delay Optimisation: will be performed using acute non-invasive blood pressure acquired using the Finometer device (Finapres Medical systems) and Echo to assess LVOT gradient change. |
| Measure | Description | Time Frame |
|---|---|---|
| Patient symptoms | Patient symptoms via patient questionnaire - Kansas City Cardiomyopathy Questionnaire. All Kansas City Cardiomyopathy Questionnaire scores are scaled from 0 to 100 and frequently summarized in 25-point ranges, where scores represent health status as follows: 0 to 24: very poor to poor; 25 to 49: poor to fair; 50 to 74: fair to good; and 75 to 100: good to excellent | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Exercise Capacity | Change in exercise capacity by 6 Minute Walk Test | 6 months |
| Exercise Capacity | Change in exercise capacity by Cardiopulmonary Exercise Testing (MVOT) |
Not provided
Inclusion criteria:
Exclusion criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Zachary I Whinnett, MRCP PhD | Imperial College London | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| National Heart & Lung Institute, Imperial College London | London | W12 0HS | United Kingdom |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30715300 | Background | Arnold AD, Howard JP, Chiew K, Kerrigan WJ, de Vere F, Johns HT, Churlilov L, Ahmad Y, Keene D, Shun-Shin MJ, Cole GD, Kanagaratnam P, Sohaib SMA, Varnava A, Francis DP, Whinnett ZI. Right ventricular pacing for hypertrophic obstructive cardiomyopathy: meta-analysis and meta-regression of clinical trials. Eur Heart J Qual Care Clin Outcomes. 2019 Oct 1;5(4):321-333. doi: 10.1093/ehjqcco/qcz006. | |
| 8624871 |
Not provided
Not provided
| Type | Date | Date Unknown |
|---|---|---|
| Release | Nov 14, 2025 | |
| Reset | Nov 24, 2025 | |
| Release | Dec 16, 2025 | |
| Reset | Jan 6, 2026 | |
| Release | Jan 27, 2026 | |
| Reset | Feb 12, 2026 | |
| Release | May 7, 2026 | |
| Reset | Jun 2, 2026 |
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Nov 14, 2025 | Nov 24, 2025 | |||
| Dec 16, 2025 |
| ID | Term |
|---|---|
| D002312 | Cardiomyopathy, Hypertrophic |
| ID | Term |
|---|---|
| D009202 | Cardiomyopathies |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D001020 | Aortic Stenosis, Subvalvular |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 6 months |
| BNP | Change in BNP - Brain Natriuretic Peptide (blood test) | 6 months |
| Patient preference of optimum pacing on or pacing off | An exploratory secondary outcome - patients will be asked at the end of the study which 3 month period they preferred (they will not be told during which 3 month period they were paced and not paced when they answer this question). | 6 months |
| Patient symptoms | Patient symptoms via patient questionnaire - EQ-5D-5L Questionnaire. EQ-5D-5L health states can be summarised using the 5-digit code or represented by a single summary number (index value), which reflects how good or bad a health state is according to the preferences of the general population of a country/region. Most EQ-5D value sets have been obtained from a standardised valuation exercise, in which a representative sample of the general population in a country/region is asked to place a value on EQ-5D health states. | 6 months |
| Patient symptoms | Patient symptoms via a smartphone daily symptom application | 6 months |
| Echo Parameters | Change in LV Ejection Fraction (measured by Simpson's Biplane %) | 6 months |
| Echo Parameters | Change in resting and peak exertion LVOT gradients (measured by Echo in mm Hg) | 6 months |
| Pacemaker / ICD Activity Data | The pacemaker / device will be interrogated to give us information about participants activity levels (hrs per day) | 6 months |
| Background |
| Slade AK, Sadoul N, Shapiro L, Chojnowska L, Simon JP, Saumarez RC, Dodinot B, Camm AJ, McKenna WJ, Aliot E. DDD pacing in hypertrophic cardiomyopathy: a multicentre clinical experience. Heart. 1996 Jan;75(1):44-9. doi: 10.1136/hrt.75.1.44. |
| 19773224 | Background | Breithardt G. MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy): cardiac resynchronization therapy towards early management of heart failure. Eur Heart J. 2009 Nov;30(21):2551-3. doi: 10.1093/eurheartj/ehp383. Epub 2009 Sep 22. No abstract available. |
| 22747698 | Background | Kyriacou A, Pabari PA, Whinnett ZI, Arri S, Willson K, Baruah R, Stegemann B, Mayet J, Kanagaratnam P, Hughes AD, Francis DP. Fully automatable, reproducible, noninvasive simple plethysmographic optimization: proof of concept and potential for implantability. Pacing Clin Electrophysiol. 2012 Aug;35(8):948-60. doi: 10.1111/j.1540-8159.2012.03435.x. Epub 2012 Jul 2. |
| 31788894 | Background | Jurak P, Curila K, Leinveber P, Prinzen FW, Viscor I, Plesinger F, Smisek R, Prochazkova R, Osmancik P, Halamek J, Matejkova M, Lipoldova J, Novak M, Panovsky R, Andrla P, Vondra V, Stros P, Vesela J, Herman D. Novel ultra-high-frequency electrocardiogram tool for the description of the ventricular depolarization pattern before and during cardiac resynchronization. J Cardiovasc Electrophysiol. 2020 Jan;31(1):300-307. doi: 10.1111/jce.14299. Epub 2019 Dec 5. |
| 23481908 | Background | Whinnett ZI, Francis DP, Denis A, Willson K, Pascale P, van Geldorp I, De Guillebon M, Ploux S, Ellenbogen K, Haissaguerre M, Ritter P, Bordachar P. Comparison of different invasive hemodynamic methods for AV delay optimization in patients with cardiac resynchronization therapy: implications for clinical trial design and clinical practice. Int J Cardiol. 2013 Oct 3;168(3):2228-37. doi: 10.1016/j.ijcard.2013.01.216. Epub 2013 Mar 5. |
| 40892619 | Derived | Mohal JS, Whinnett ZI, Mohiddin SA, Malcolmson J, Elliott P, Ormerod JOM, Prasad S, Ware JS, Cooper RM, Tanner MA, Khalique Z, Shah JS, Keene D, Tangkongpanich P, Lewis EC, Sharma C, Reddy RK, Naraen A, Saleh K, Samways JW, Howard JP, Artico J, Kanagaratnam P, Francis DP, Al-Lamee RK, Varnava A, Shun-Shin MJ, Arnold AD. Electromechanically Optimized Right Ventricular Pacing for Obstructive Hypertrophic Cardiomyopathy: The EMORI-HCM Trial. J Am Coll Cardiol. 2026 Jan 20;87(2):124-139. doi: 10.1016/j.jacc.2025.08.050. Epub 2025 Aug 31. |
| Jan 6, 2026 |
| Jan 27, 2026 | Feb 12, 2026 |
| May 7, 2026 | Jun 2, 2026 |
| D001024 |
| Aortic Valve Stenosis |
| D000082862 | Aortic Valve Disease |
| D006349 | Heart Valve Diseases |