In this study is tested the validity of placental vascular indices obtained from placenta ultrasonographic sphere biopsy and entire placenta investigation.
Although, to this date, there have been a number of human placental studies that concerned the evaluation of placental 3 dimensional power Doppler vascularization with the use of VOCAL technique, but there was no one in which placental vasculature has been compared between the sonobiopsy and whole placental volume.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Normal placenta-entitle | Experimental | The 3-DPD indices was measured in the entire placenta volume. |
|
| Normal placenta-sonobyopsy | Experimental | The 3-DPD indices was measured at cord insertion in placenta by sonobiopsy |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 3 dimensional ultrasound investigation | Diagnostic Test | Images that contributed to the determination of placental volume and 3-DPD indices were obtained at the time of visit. All 3-D scans ultrasound measurements were performed by a Voluson 730 Expert ultrasound machine equipped with a multifrequency probe (2-5 MHz) to acquire images. Each sample was examined using 3-D rendering mode, in which the colour and gray value information was processed and combined to supply 3-D image. For laterally located placentas, the investigator positioned the transducer on a slight lateral inclination to obtain proper images. Power Doppler window was placed over the placenta to map the vascular tree from basal to chorionic plates. The 3-D static volume box was placed over the entire placenta volume. The sweep angle was set at maximum 70°. Each image was recovered from the disk in succession for processing. During gestation, the investigator recorded one sample from each patient. |
| Measure | Description | Time Frame |
|---|---|---|
| Maternal characteristics (BMI) | The pre-pregnancy body mass index (BMI) registered at the initial visit during prenatal care was calculated as the body weight (kg) per height (m2). | through study completion, 2 years |
| Neonatal outcome 1; based on gestational age | The participants were recorded by gestational age et birth | during first day of life |
| Neonatal outcome 2, based on maturation of neonates | Neonates were investigatied by maturation ( gestational age before 36+6 week) (prematurity | during first day of life |
| Neonatal outcome 3, (birth weight of newborns) | Neonates birth weight calculation (gram) | during first day of life |
| Neonatal outcome 4; Apgar score | Neonates poor adaptation status (Apgar score (<7) at 5 minutes) | during first day of life |
| Neonatal outcome 5, (umbilical cord pH) | Neonates poor adaptation status (umbilical cord pH <7.2) | during first day of life |
| Neonatal outcome 6; delivery complication | Delivery complication ( cesarean section due to fetal distress) | during first day of life |
| Neonatal outcome 7, necessary of intensive care unit |
| Measure | Description | Time Frame |
|---|---|---|
| 2D ultrasound investigaiotn of gestation (fetal biometry, placentation) | Routine ultrasound examination, based on Guideline of Hungarian Obstetrics and gynecologists (fetal biometry: biparietal diameter, head circumference, abdominal circumference, femur length; investigation of the placenta, place of placentation, Grannum staging) | during prenatal care till the labour |
Not provided
Exclusion criteria:
Inclusion clriteria:
The investigator studed pregnat women to analise the placental funciton in-vivo.
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Tibor Wittman, Professor | ALBERT SZENT-GYÖRGYI CLINICAL CENTER. REGIONAL SCIENTIFIC AND RESEARCH COMMITTEE FOR HUMAN BIOLOGICAL SCIENCE. | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Universitiy of Szeged | Szeged | 6720 | Hungary |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 21324404 | Background | Odibo AO, Zhong Y, Longtine M, Tuuli M, Odibo L, Cahill AG, Macones GA, Nelson DM. First-trimester serum analytes, biophysical tests and the association with pathological morphometry in the placenta of pregnancies with preeclampsia and fetal growth restriction. Placenta. 2011 Apr;32(4):333-8. doi: 10.1016/j.placenta.2011.01.016. Epub 2011 Feb 13. | |
| 28651459 |
| Label | URL |
|---|---|
| Matijevic R, Kurjak A. The assessment of placental blood vessels by three-dimensional power Doppler ultrasound | View source |
Not provided
Not provided
| ID | Term |
|---|---|
| D010922 | Placenta Diseases |
| ID | Term |
|---|---|
| D011248 | Pregnancy Complications |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
| D000091642 | Urogenital Diseases |
Not provided
Not provided
A prospective cohort study was conducted among normal pregnant women recruited at 11 to 40 gestational weeks. Placental vascularization was evaluated using the 3-DPD-indices (vascularization-index (VI); flow-index (FI); vascularization-flow-index (VFI)) with the application of the sphere-technique or scanned from the entire placenta
Not provided
Not provided
Not provided
Not provided
|
| 2 dimensional ultrasound investigation | Diagnostic Test | The two-dimensional (2-D) transabdominal conventional study provided data about fetal position, biometry, body movements and fetal heart rate as well as placental localization. The factorial default setting 'Obstetrics' was applied in 2-D mode. |
|
Neonates transfer to neonatal intensive care unit (NICU) |
| during first week of life |
| Molnar A, Suranyi A, Jako M, Nyari T, Nemeth G. [Examination of placental three-dimensional power Doppler indices and perinatal outcome in pregnancies complicated by intrauterine growth restriction]. Orv Hetil. 2017 Jul;158(26):1008-1013. doi: 10.1556/650.2017.30784. Hungarian. |
| 25959054 | Background | Kozinszky Z, Suranyi A, Peics H, Molnar A, Pal A. Placental Volumetry by 2-D Sonography with a New Mathematical Formula: Prospective Study on the Shell of a Spherical Sector Model. Ultrasound Med Biol. 2015 Aug;41(8):2252-8. doi: 10.1016/j.ultrasmedbio.2015.04.005. Epub 2015 May 7. |
| 23219036 | Background | Collins SL, Stevenson GN, Noble JA, Impey L. Rapid calculation of standardized placental volume at 11 to 13 weeks and the prediction of small for gestational age babies. Ultrasound Med Biol. 2013 Feb;39(2):253-60. doi: 10.1016/j.ultrasmedbio.2012.09.003. Epub 2012 Dec 4. |
| 21656781 | Background | Moran M, McAuliffe FM. Imaging and assessment of placental function. J Clin Ultrasound. 2011 Sep;39(7):390-8. doi: 10.1002/jcu.20846. Epub 2011 Jun 8. |
| 21701132 | Background | Plasencia W, Akolekar R, Dagklis T, Veduta A, Nicolaides KH. Placental volume at 11-13 weeks' gestation in the prediction of birth weight percentile. Fetal Diagn Ther. 2011;30(1):23-8. doi: 10.1159/000324318. Epub 2011 Jun 23. |
| 15188796 | Background | Merce LT, Barco MJ, Bau S. Reproducibility of the study of placental vascularization by three-dimensional power Doppler. J Perinat Med. 2004;32(3):228-33. doi: 10.1515/JPM.2004.043. |
| Odibo AO, Goetzinger KR, Huster KM, Christiansen JK, Odibo L, Tuuli MG. Placental volume and vascular flow assessed by 3D power Doppler and adverse pregnancy outcomes | View source |
| Tuuli MG, Houser M, Odibo L, Huster K, Macones GA, Odibo AO. Validation of placental vascular sonobiopsy for obtaining representative placental vascular indices by three-dimensional power Doppler ultrasonography | View source |
| Evaluation of placental vascularization by three-dimensional ultrasound examination in second and third trimester of pregnancies complicated by chronic hypertension, gestational hypertension or pre-eclampsia | View source |
| Demers S, Boutin A, Dembickaja R, Campanero M, Nicolaides K. Factors Associated with Placental Vascularization Measured by 3D Power Doppler Ultrasonographic Sphere Biopsy between 11 and 14 Weeks of Gestation | View source |
| Demers S, Girard M, Roberge S, Tetu A, Giguere Y, Forest J-C, et al. First-Trimester Placental and Myometrial Blood Perfusion Measured by Three-Dimensional Power Doppler in Preeclampsia | View source |