Although there is a widespread use of HighFlow therapy around the world, there is still uncertainty about the most appropriate initial HighFlow level after nasal continuous positive airway pressure therapy. Higher levels might produce excessive and harmful intra-alveolar pressures exceeding those reached during nasal continuous positive airway pressure therapy. Low levels may not generate sufficient distending pressures, which may result in a loss of functional residual capacity and an increased risk of respiratory failure. Therefore, the aim of this study is to assess the effect of different HighFlow levels on the functional residual capacity and to compare these findings to the functional residual capacity during nasal continuous positive airway pressure therapy.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| High Flow | Other | Standard HighFlow therapy after weaning from continuous positive airway pressure therapy will be applied on different flow levels. Starting with a flow level of 8l/min, the flow-rates will be changed every 30 minutes subsequently from 8-6-4-2-4-6-8 l/min. Meanwhile, data lung volume changes will be measured using electrical impedance tomography. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| High Flow | Device | Standard HighFlow therapy after weaning from continuous positive airway pressure therapy will be applied on different flow levels. Starting with a flow level of 8l/min, the flow-rates will be changed every 30 minutes subsequently from 8-6-4-2-4-6-8 l/min. Meanwhile, data on lung volume changes will be measured using electrical impedance tomography. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in global end-expiratory lung impedance (EELI) during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Change in global EELI over time using electrical impedance tomography (EIT) | 230-minute recording period per patient, 30 minutes on each HF level |
| Measure | Description | Time Frame |
|---|---|---|
| Change in mean respiratory rate (RR) during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Change in RR over time using electrical impedance tomography (EIT) | 230-minute recording period per patient, 30 minutes on each HF level |
| Change in regional end-expiratory lung impedance (EELI) during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Newborn Research, Department of Neonatology, University Hospital Zurich | Zurich | 8091 | Switzerland |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23260098 | Background | Collins CL, Holberton JR, Barfield C, Davis PG. A randomized controlled trial to compare heated humidified high-flow nasal cannulae with nasal continuous positive airway pressure postextubation in premature infants. J Pediatr. 2013 May;162(5):949-54.e1. doi: 10.1016/j.jpeds.2012.11.016. Epub 2012 Dec 20. | |
| 27596161 | Background |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D007235 | Infant, Premature, Diseases |
| D012128 | Respiratory Distress Syndrome |
| ID | Term |
|---|---|
| D007232 | Infant, Newborn, Diseases |
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |
| D008171 | Lung Diseases |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
Change in regional EELI over time using electrical impedance tomography (EIT) |
| 230-minute recording period per patient, 30 minutes on each HF level |
| Change in mean minute volume during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Change in mean minute volume over time using electrical impedance tomography (EIT), (AU/kg/min) | 230-minute recording period per patient, 30 minutes on each HF level |
| Change in mean ventilation distribution during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Change in mean ventilation distribution over time using electrical impedance tomography (EIT), (%, left/right and ventral/dorsal) | 230-minute recording period per patient, 30 minutes on each HF level |
| Change in mean silent spaces during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Change in mean silent spaces over time using electrical impedance tomography (EIT), (%, dependent, non-dependent lung) | 230-minute recording period per patient, 30 minutes on each HF level |
| Change in mean tidal volume during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Change in mean tidal volume over time using electrical impedance tomography (EIT), (AU/kg) | 230-minute recording period per patient, 30 minutes on each HF level |
| Change in number of apnoea that required stimulation during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Change in number of apnoea over time | 230-minute recording period per patient, 30 minutes on each HF level |
| Change in heart rate during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Change in heart rate over time | 230-minute recording period per patient, 30 minutes on each HF level |
| Change in oxygen saturation during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Change in oxygen saturation over time, SpO2, % | 230-minute recording period per patient, 30 minutes on each HF level |
| Change in fraction of inspired oxygen during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Change in fraction of inspired oxygen over time | 230-minute recording period per patient, 30 minutes on each HF level |
| Change in reaching 'failure criteria' to stop HighFlow therapy during the weaning procedure from nasal continuous positive airway pressure (nCPAP) to HighFlow (HF) | Definition of failure criteria:
| 230-minute recording period per patient, 30 minutes on each HF level |
| Frerichs I, Amato MB, van Kaam AH, Tingay DG, Zhao Z, Grychtol B, Bodenstein M, Gagnon H, Bohm SH, Teschner E, Stenqvist O, Mauri T, Torsani V, Camporota L, Schibler A, Wolf GK, Gommers D, Leonhardt S, Adler A; TREND study group. Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group. Thorax. 2017 Jan;72(1):83-93. doi: 10.1136/thoraxjnl-2016-208357. Epub 2016 Sep 5. |
| 24561568 | Background | van der Burg PS, Miedema M, de Jongh FH, Frerichs I, van Kaam AH. Cross-sectional changes in lung volume measured by electrical impedance tomography are representative for the whole lung in ventilated preterm infants. Crit Care Med. 2014 Jun;42(6):1524-30. doi: 10.1097/CCM.0000000000000230. |