In some cases the standard J-tip guidewire cannot deliver the catheter into the aortic root, because of arterial loops or spasm. In these cases a hydrophilic guidewire (Terumo) gives the right lubricity and good shape retention to guide the catheter through the artery. However, the Terumo wire does not give much torque and could therefore easily penetrate side branches and cause dissection or perforation. The latest Silverway guidewire has some new advantages which is easier to guide and could cause less complications while faster delivery of catheters to the aortic valve. The investigators aim to compare both guide wires.
During cardiac catheterization a catheter is threaded through the radial arteries to the aortic root with the support of a guide wire. The standard workhorse to deliver the catheter is a J-tip guidewire (spring coil wire). However, in patients with arterial tortuosity or spasm, this guidewire has low lubricity and no torque to direct the catheter because the outer coil and core are not connected together.
If this problem is encountered, interventional cardiologists will use a hydrophilic polymer-coated guide wire. Up to date there are several hydrophilic coated guide wires available. One of these is the Radifocus Guide Wire M (Terumo, Japan). Although it has better torque transmission than the spring wire, it still has low torque transmission due to a Nitinol core structure, is less supportive and can easily enter side branches because of the high lubricity and therefore might cause dissections or perforations.
In some cases, coronary angioplasty guide wires are needed to negotiate a highly tortuous artery, but they lack the support to advance the catheter.
Recently, the Silverway Guide Wire has been created (Asahi Intecc Co, LTD., Japan) to overcome the problems that a spring- and polymer wire have. Features that this new guide wire provide is hybrid coating and ACT ONE technology that connects the wire core and coil to ensure one to one torque transmission The investigators aim to compare both guide wires in deliverability, workability and complication rate.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Below the shoulder vascular anomaly | Placebo Comparator | If the standard J-tip guidewire does not cross a vascular anomaly located below the shoulder |
|
| Above the shoulder vascular anomaly | Active Comparator | If the standard J-tip guidewire does not cross a vascular anomaly located above the shoulder |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Silverway guidewire | Device | The Silverway guidewire is a newly developed guidewire to overcome the problems the Radifocus guidewire has |
|
| Measure | Description | Time Frame |
|---|---|---|
| Time in seconds from introduction to aortic root | Measuring time from entering the guidewire in the catheter to delivery of the catheter to the aortic root (in seconds) | During procedure |
| Measure | Description | Time Frame |
|---|---|---|
| The ability of the study wire to deliver the catheter to the aortic root | If the study wire is able to deliver the catheter to the aortic root | During procedure |
| Change of access site | Is change of access site necessary? |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Koen Ameloot, Dr. | Ziekenhuis Oost-Limburg | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ziekenhuis Oost-Limburg | Genk | Limburg | 3600 | Belgium |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D054079 | Vascular Malformations |
| ID | Term |
|---|---|
| D018376 | Cardiovascular Abnormalities |
| D002318 | Cardiovascular Diseases |
| D000013 | Congenital Abnormalities |
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Radifocus guidewire | Device | The Radifocus guidewire is a hydrophilic coated guidewire that is used when a standard J-tip guidewire does not cross a vascular anomaly |
|
| During procedure |
| Interventional cardiologists' survey of grading parameters working with the guide wire | The interventional cardiologist who used the study wire must fill up a survey after procedure to grade the workability and deliverability of the study wire | Directly after procedure. Scale: not satisfactory (1) - somewhat satisfactory (2) - satisfactory (3) |