This is Prospective Basic Science Study whose aims are as follows:
The outcome measures are as follows:
The use of facemasks is one of the key strategies for reducing human to human transmission of SARS-CoV-2. There is a variety of facemasks worn in the clinical environment ranging from simple facemasks to devices such as filtering face piece 3M (FFP3M) respirators which are mandatory for some clinicians performing aerosol generating procedures (AGPs.)
It has been shown that wearing face protective equipment attenuates sound causing decay in speech intelligibility, especially transmission of middle-to-high voice frequencies.It has been shown that wearing surgical masks results in up to 23.3% loss of speech intelligibility in noisy environments with advanced face personal protective equipment such as FFP3M devices, accounting for up to 69.0% reduction of speech intelligibility. A reduction in speech intelligibility leads to reduced understanding which may result in miscommunication thereby compromising patient safety. To date, there have been two critical incidents in our department due to miscommunication attributed to wearing FFP3M respirators.
Anecdotally, clinicians have reported nasal congestion and subjective hearing loss during FFP3M respirator usage and after, especially when they are worn for a prolonged period of time. Clinicians working in theatre may be required to wear these devices for a number of hours when involved with AGPs.
The secondary consequences of wearing FFP3M respirators for prolonged periods of time, especially in a theatre setting require scientific exploration. This study aims to investigate the effect of FFP3M respirators on middle ear pressure and hearing, and the extent to which FFP3M respirators attenuate sound. Investigators believe that a reduction in speech intelligibility is not the only explanation for the perception of hearing loss when using FFP3M respirators. Investigators postulate that a transient dysfunction in the eustachian tube pressure regulating system also contributes to hearing loss.
To test this hypothesis, investigators will measure hearing and middle ear pressure using pure tone audiometry and tympanometry before and during FFP3M usage. Investigators will also use SNOT-22 and ETDQ7 questionnaires which are validated patient reported outcome measures for nasal symptoms and eustachian tube function. Investigators hope that this study provides some understanding of the physiological effects of FFP3M respirators on hearing and sinonasal symptoms and improves our understanding of their impact on clinical practice. There are no current studies looking into the effects of FFP3M respirators on eustachian tube function.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| FFP3 Respirator | Experimental | Participants will wear FFP3 respirators during the study. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| FFP3 Mask | Other | Participans will wear FFP3 respirators during the study. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Changes in baseline pure tone audiometry post intervention. | We will measure changes in baseline pure tone audiometry post FFP3 respirator usage.. | 48 hours |
| Measurement of speech attenuation in decibels. | We will measure speech attenuation in decibels when participants are wearing FFP3 respirators | 1 hours |
| Changes in baseline tympanometry post intervention | We will measure changes in baseline tympanometry post FFP3 respirator usage. | 48 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Eustachian tube function | Participants will complete the SINO-NASAL OUTCOME TEST (SNOT-22) Questionnaire which is a 22 point questionnaire. Participants will be asked to grade the severity of their symptoms from 1-5 with with higher scores denoting severe symptoms. The questionnaires will be completed pre and post interventions to investigate changes in eustachian tube function. | 48 hours |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Nazia Munir, FRCS ORL-HNS | Contact | 07970921448 | nazir.munir@liverpoolft.nhs.uk | |
| Todd Kanzara, FRCS ORL-HNS | Contact | 07796945100 | todd.kanzara@nhs.net |
Not provided
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 33138498 | Background | Corey RM, Jones U, Singer AC. Acoustic effects of medical, cloth, and transparent face masks on speech signals. J Acoust Soc Am. 2020 Oct;148(4):2371. doi: 10.1121/10.0002279. | |
| 33389012 | Background | Muzzi E, Chermaz C, Castro V, Zaninoni M, Saksida A, Orzan E. Short report on the effects of SARS-CoV-2 face protective equipment on verbal communication. Eur Arch Otorhinolaryngol. 2021 Sep;278(9):3565-3570. doi: 10.1007/s00405-020-06535-1. Epub 2021 Jan 3. |
Not provided
Not provided
No data will be shared with other researchers
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006311 | Hearing Disorders |
| D015508 | Nasal Obstruction |
| D034381 | Hearing Loss |
| ID | Term |
|---|---|
| D004427 | Ear Diseases |
| D010038 | Otorhinolaryngologic Diseases |
| D012678 | Sensation Disorders |
| D009461 | Neurologic Manifestations |
Not provided
Not provided
Prospective open label basic science study.
Not provided
Not provided
Not provided
Not provided
| Eustachian tube function | Participants will complete the Eustachian Tube Dysfunction Questionnaire (ETDQ-7) which is a 7 point questionnaire. Patients are asked to grade the severity of their symptoms from 1-7 with with higher scores denoting severe symptoms. The questionnaires will be completed pre and post interventions to investigate changes in eustachian tube function. | 48 hours |
| 32641175 | Background | Hampton T, Crunkhorn R, Lowe N, Bhat J, Hogg E, Afifi W, De S, Street I, Sharma R, Krishnan M, Clarke R, Dasgupta S, Ratnayake S, Sharma S. The negative impact of wearing personal protective equipment on communication during coronavirus disease 2019. J Laryngol Otol. 2020 Jul;134(7):577-581. doi: 10.1017/S0022215120001437. Epub 2020 Jul 28. |
| 19793277 | Background | Hopkins C, Gillett S, Slack R, Lund VJ, Browne JP. Psychometric validity of the 22-item Sinonasal Outcome Test. Clin Otolaryngol. 2009 Oct;34(5):447-54. doi: 10.1111/j.1749-4486.2009.01995.x. |
| 22374681 | Background | McCoul ED, Anand VK, Christos PJ. Validating the clinical assessment of eustachian tube dysfunction: The Eustachian Tube Dysfunction Questionnaire (ETDQ-7). Laryngoscope. 2012 May;122(5):1137-41. doi: 10.1002/lary.23223. Epub 2012 Feb 28. |
| D009422 | Nervous System Diseases |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D009668 | Nose Diseases |
| D012140 | Respiratory Tract Diseases |
| D000402 | Airway Obstruction |
| D012131 | Respiratory Insufficiency |
| D012120 | Respiration Disorders |