Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The aim of our study is investigated validity and reliabilty of Modified Box and Block Test and Targeted Box and Block Test in patients with stroke.
Fifty patients with stroke will included in the study. Box and Block Test, Modified Box and Block Test, Targeted Box and Block Test, 9 Hole Peg Test, Fugl-Meyer Assessment of the upper extremity will used to assess upper extremity. To evaluate validity between Modified and Targeted Box and Block Tests and Box and Block Test, 9 Hole Peg Test, Fugl-Meyer Assessment will used to correlation analysis tests. The investigator will evaluate after one week to test-retest reliability to patients. Other pyhsiotherapist will evaluate to patients inter-rater reliability.
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Modified Box and Block Test | The Modified Box and Block (mBBT) test is an upper extremity performance test.Unlike BBT, in mBBT, instead of randomly picking the cubes, 16 cubes are arranged in a certain order. The cubes are asked to take the other cubes in that row, starting from the innermost left cube, first to the right, and then to the next upper row. It is recorded how many seconds passed through 16 cubes placed at a certain level. | 10 minute |
| Targeted Box and Block Test | In tBBT, as in mBBT, the time of passing 16 cubes over the obstacle to the other side is recorded. However, the difference from mKBT is that 16 cubes are placed at a certain level, but the patients are asked to place the cubes on the other side in 4 cm squares where the cube will be placed. These squares correspond to the left symmetrical position of the cube on the right. In this way, patients have to place the cube they grasp only at the desired point. | 10 minute |
| Measure | Description | Time Frame |
|---|---|---|
| 9 Hole Peg Test | 9HPT is a dexterity test.The patient is asked to place the 9 wooden blocks into the 9 holes in the maximum amount of time.Then he is asked to take it out and put it back in its place. The total time is recorded. | 10 minute |
| Fugl-Meyer Assessment for Upper Extremity |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients with stroke
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Lütfiye AKKURT, MSc | Kutahya Health Sciences University | Principal Investigator |
| Cihan Caner AKSOY, PhD | Kutahya Health Sciences University | Study Director |
| Fatıma YAMAN, MD | Kutahya Health Sciences University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Kutahya Health Sciences University | Kütahya | 43100 | Turkey (Türkiye) |
Not provided
| ID | Term |
|---|---|
| D020521 | Stroke |
| ID | Term |
|---|---|
| D002561 | Cerebrovascular Disorders |
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
The Fugl-Meyer Assessment is a disease-specific impairment index designed to assess motor function, balance, sensation qualities and joint function in hemiplegic post-stroke patients.The scale consists of four categories (Shoulder/Elbow/Forearm, Wrist, Hand/Finger, and Coordination) and evaluates 23 different movements in 33 sections.The maximum score is 66 points |
| 15 minutes |
| Box and Block Test | Box and Block (mBBT) test is an upper extremity performance test. The patient is instructed to move as many blocks as possible, one at a time, from one compartment to the other for a period of 60 seconds. The number of cubes passed to the other side in 60 seconds is recorded. | 5 minute |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |