EUS-guided biliary drainage is gaining popularity as a means of achieving endoscopic drainage in patients with failed endoscopic retrograde cholangiopancreatography (ERCP) 1. EUS-guided hepaticogastrostomy (HGS) is a type of EUS-guided biliary drainage and the procedure is employed when the ERCP fails due to a malignant bile duct obstruction but the papilla is inaccessible or if the first of the duodenum is infiltrated by tumor. Recently, a novel dedicated HGS (Niti-S, Taewoong Medical, Gyeonggi-do, Korea) has become available, the stent has a novel design to that prevents the stent from migration, further improving the safety.
The aim of the current study is to evaluate the feasibility and outcomes of the novel lumen apposing stent for EUS-guided HGS. The hypothesis is that the device is safe and effective.
This is a prospective feasibility study enrolling patients suffering from malignant biliary obstruction with failed or anticipated difficult ERCP. Consecutive patients satisfying the inclusion criteria would be recruited.
EUS-guided hepaticogastrostomy would be performed with the MG-biliary stent. The MG-biliary stent (Niti-S, Taewoong Medical, Gyeonggi-do, Korea) is a novel device designed for hepaticogastrostomy. The stent is a partially covered metal stent made by nitinol covered with silicone. One end of the stent is uncovered and designed for placement in the intrahepatic ducts. The other end has a self-folding design that creates a flange and prevents migration of the stent outside the stomach. The stent diameter is either 8 or 10mm and the length can be 6,8,10 or 12cm long.
Outcome parameters include safety, technical and clinical success
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| EUS-guided hepaticogastrostomy | Experimental | EUS-guided hepaticogastrostomy would be performed with the MG-biliary stent (Niti-S, Taewoong Medical, Gyeonggi-do, Korea). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| EUS-guided hepaticogastrostomy | Device | EUS-guided hepaticogastrostomy would be performed with the MG-biliary stent (Niti-S, Taewoong Medical, Gyeonggi-do, Korea) |
|
| Measure | Description | Time Frame |
|---|---|---|
| Adverse event | a life-threatening or severe event requiring endoscopic and/or surgical intervention, transfusion or IV/IM antibiotics | 30 day |
| Measure | Description | Time Frame |
|---|---|---|
| Number of patients with technical success | transmural placement of the stent across the stomach or duodenum into the bile duct | 1 day |
| Number of patients with Clinical success | decrease of >20% bilirubin from baseline level |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Anthony Teoh, FRCSEd | Contact | 35052956 | anthonyteoh@surgery.cuhk.edu.hk | |
| Zero Chung | Contact | 35052956 | zerochung@surgery.cuhk.edu.hk |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Surgery, Prince of Wales Hospital | Recruiting | Hong Kong | Hong Kong |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 34427190 | Background | Ogura T, Ueno S, Okuda A, Nishioka N, Yamada M, Matsuno J, Ueshima K, Yamamoto Y, Higuchi K. Technical feasibility and safety of one-step deployment of EUS-guided hepaticogastrostomy using an 8-mm diameter metal stent with a fine-gauge stent delivery system (with video). Endosc Ultrasound. 2021 Sep-Oct;10(5):355-360. doi: 10.4103/EUS-D-20-00206. | |
| 29463614 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
EUS-guided hepaticogastrostomy would be performed with the MG-biliary stent
Not provided
Not provided
Not provided
Not provided
| 7 days |
| Stent patency | the period between stent insertion and stent occlusion or stent removal | 1 year |
| Teoh AYB, Dhir V, Kida M, Yasuda I, Jin ZD, Seo DW, Almadi M, Ang TL, Hara K, Hilmi I, Itoi T, Lakhtakia S, Matsuda K, Pausawasdi N, Puri R, Tang RS, Wang HP, Yang AM, Hawes R, Varadarajulu S, Yasuda K, Ho LKY. Consensus guidelines on the optimal management in interventional EUS procedures: results from the Asian EUS group RAND/UCLA expert panel. Gut. 2018 Jul;67(7):1209-1228. doi: 10.1136/gutjnl-2017-314341. Epub 2018 Feb 20. |