Observational, prospective, single-arm and multi-center study to assess the safety and feasibility of IVUS imaging in the setting of TAVI and to describe the angiographic and intravascular ultrasound features in patients with coronary arteries deemed at high-risk for coronary artery obstruction following TAVI.
CHIMNEY stenting is a reasonable strategy to manage catastrophic coronary artery obstruction (CAO). However, this technique is frequently used, not for acute catastrophic CAO (clinically evident), but preventively because the operator believes that CAO may occur on complete transcatheter heart valve (THV) deployment or after the protective coronary guidewire is withdrawn (3/5 of cases). Consequently, in current clinical practice, many patients receive CHIMNEY stents that are not required, and thus incur the associated risks of this procedure. To date, operators do not know how many patients, among those underwent preventive CHIMNEY, really required stenting, or on the contrary, did not. Also, accordingly, a real estimation of CAO incidence is not possible, but is likely higher than that reported in previous studies.
At present, no objective measures have been identified that could help operators decide when to deploy a CHIMNEY stent. If it could be demonstrated in the catheterization laboratory that the displaced native or bioprosthetic leaflets were sufficiently far away from the native coronary ostia and the risk for CAO was low, then unnecessary CHIMNEY stenting could be avoided.
Angiographic images do not provide sufficient information to clarify that. The investigation of a coronary ostium at risk of CAO from an intravascular point of view may reveal the presence of the displaced leaflet in front of them, or on the other hand, its absence, supporting operators in the decision to stent or not to stent.
In addition to the potential for IVUS to determine when CHIMNEY stenting should be used, this technique may also be used to optimize the results of CHIMNEY stenting when it has been deployed.
Moreover, IVUS can also be used to assess the result of the BASILICA technique after leaflet laceration.
The hypothesis is that the use of IVUS imaging for the assessment of patency of the coronary ostium and of the relationship of displaced valve leaflets towards the coronary arteries may reveal novel risk factors to predict which are not detectable by traditional angiography.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| IVUS-guided | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| IVUS assessment of coronary ostia | Device | For coronary arteries at high-risk of obstruction during TAVI in native valves or valve-in-valve TAVI:
|
| Measure | Description | Time Frame |
|---|---|---|
| Incidence of IVUS assessement success | Feasibility of IVUS assessement after the valve implantation (Yes, No) | Within the same 1 procedural day |
| Incidence of IVUS assessment-related adverse events | Safety of IVUS assessement. Composite of any clinical complication related to the attempted insertion of the IVUS catheter into the coronary artery, including: dissection, perforation, thrombosis, or flow impairment of the at-risk coronary or damage to the aortic wall or the THV during insertion of the IVUS catheter prior to or after TAVI. | Within the same 1 procedural day |
| Measure | Description | Time Frame |
|---|---|---|
| CHIMNEY stenting rate | Comparison between the actual rate of CHIMNEY stenting performed after the final IVUS assessment, and the rate of potential CHIMNEY stenting reported by operators on the only basis of CT and angiography images (before IVUS assessment). This will provide information about the number of stents that could be "spared" because deemed useless after the more accurate IVUS study | Within the same 1 procedural day |
Not provided
Inclusion Criteria:
6a. TAVI in native valves: height of the coronary ostium (<9 mm), sinuses of Valsalva width <30 mm, leaflet tips extending above the coronary ostia or the sino-tubular junction.
6b. VIV-TAVI (patients undergoing BASILICA as first prevention strategy are also included): surgical bioprosthesis type: with supra-annular position, high leaflet profile, externally mounted leaflets stented valve, stentless valves, and bulky leaflets, low-lying coronary ostia (< 9 mm from the ostia to the sewing ring), narrow sinuses of Valsalva (<30 mm by width for Valsalva sinuses), virtual THV-coronary (VTC) distance <4 mm, virtual THV-STJ (VT-STJ) distance < 2.5-3.5 mm: to be considered in cases where VTC >4mm but the leaflet extends above or very close (up to 2mm below) to the STJ plane.
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Flavio Ribichini, MD | Contact | +39 045 812 2320 | flavio.ribichini@univr.it |
| Name | Affiliation | Role |
|---|---|---|
| Flavio Ribichini, MD | Universita di Verona | Principal Investigator |
| Darren Mylotte, MD, PhD | National University of Ireland Galway, Ireland. University College Hospital Galway, Ireland. | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| AOUI Verona | Recruiting | Verona | 37100 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 32894228 | Background | Pighi M, Lunardi M, Pesarini G, Castriota F, Venturi G, Gottin L, Scarsini R, Ferrero V, Ribichini FL. Intravascular ultrasound assessment of coronary ostia following valve-in-valve transcatheter aortic valve implantation. EuroIntervention. 2021 Feb 19;16(14):1148-1151. doi: 10.4244/EIJ-D-20-00611. No abstract available. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D054059 | Coronary Occlusion |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| MACE | Major Adverse Cardiovascular Events (MACE) occurred among patients treated with CHIMNEY stenting or with a deferred stent strategy at discharge, 30-day and 1-year follow-up | 1 month, 1 year. |
| IVUS-angiography agreement rate | The rate of agreement between angiography and IVUS evaluation of coronary ostia:
| Procedural 1 day |
| Stent-optimization rate | The rate of stent optimization (post-dilatation or adjunctive stents) guided by IVUS assessment (only in stented coronaries) | Procedural 1 day |
| D014652 |
| Vascular Diseases |