This study is designed as a prospective, multicentric, clinical study to investigate the performance of the Panbioâ„¢ COVID-19/ Flu A&B Rapid Panel for the qualitative detection of COVID-19 antigen, Influenza A antigen (H1N1 and H3N2), and Influenza B antigen in human nasal swabs.
This study is part of the performance evaluation to support the CE conformity assessment procedures.
After obtaining written informed consent, a study-specific participant identification number (ID) will be assigned to the participant. Participant demographics and a brief medical history will be collected.
One nasal swab sample will be collected from both nostrils by operators and will be used to perform the Panbioâ„¢ COVID-19/ Flu A&B Rapid Panel test either in a laboratory or in a non-laboratory setting (e.g. GP (general practitioner) centre or hospital clinic). Each Panbioâ„¢ COVID-19/ Flu A&B Rapid Panel result will be photographed by the observer at the time of test interpretation.
Nasopharyngeal samples will be collected and used for RT-PCR (Reverse transcription polymerase chain reaction) testing as per local procedures.
Nasal samples must always be collected prior to the Nasopharyngeal sampling. A minimum of 90 Flu A positive subjects, a minimum of 90 Flu B positive subjects and a minimum of 100 SARS-CoV-2 positive subjects will be enrolled. In addition, a minimum of 385 negative subjects will be enrolled.
In total, a minimum of 665 male and female subjects will be prospectively enrolled at multiple clinical sites.
Collection procedure will be a mid-turbinate nasal swab (deep nasal swab), by turning the swab five times in each nostril. Nasal samples must be collected prior to the Nasopharyngeal sampling.
The collected swab will be tested with the Panbioâ„¢ COVID-19/ Flu A&B Rapid Panel at the study site. Tubes and swabs should be labelled with the patient ID.
After the nasal sampling, study staff personnel will also collect one nasopharyngeal swab. The nasopharyngeal swab will be eluted in Universal Transport Media (UTM) and used for testing with RT-PCR protocols for Flu A, Flu B and SARS-CoV-2 as per local procedures.
The RT-PCR methods used must have CE marking or FDA approval, with COVID-19 and Flu assay clearance for nasopharyngeal specimens. Nasopharyngeal sampling should be performed by trained healthcare professionals who routinely conduct nasopharyngeal sampling as part of their other standard of care and clinical duties.
Each operator who performs a Panbioâ„¢ COVID-19/ Flu A&B Rapid Panel test will fill out a user evaluation questionnaire once, to assess the usability of the device.
All other aspects of the Subject's care will remain the same with no deviation from prescribed practice.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Panbioâ„¢ COVID-19/ Flu A&B Rapid Panel | Other | One nasal swab sample will be collected from both nostrils by operators and will be used to perform the Panbioâ„¢ COVID-19/ Flu A&B Rapid Panel test either in a laboratory or in a non-laboratory setting (e.g. GP centre or hospital clinic). Each Panbioâ„¢ COVID-19/ Flu A&B Rapid Panel result will be photographed by the observer at the time of test interpretation. Nasopharyngeal samples will be collected and used for RT-PCR testing as per local procedures. Nasal samples must always be collected prior to the Nasopharyngeal sampling. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| COVID-19/ Flu A&B Rapid Panel | Device | Rapid Diagnostic Device |
|
| Measure | Description | Time Frame |
|---|---|---|
| Sensitivity and Specificity | Sensitivity of 70% is the target at the lower bound of the 95% confidence interval for SARS-CoV-2 and 70% for each Flu. The target specificity is 95% at the lower bound of the 95% confidence interval for each test line. | 8 months |
| Measure | Description | Time Frame |
|---|---|---|
| Usability | The secondary objective of this study is to assess the usability of the Panbioâ„¢ Rapid Panel, as collected by trained healthcare workers. | 8 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
• Subject has had a nasal or a nasopharyngeal swab taken within the last 4 hours.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Urgent Care | Easley | South Carolina | 29640 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000086382 | COVID-19 |
| ID | Term |
|---|---|
| D011024 | Pneumonia, Viral |
| D011014 | Pneumonia |
| D012141 | Respiratory Tract Infections |
| D007239 | Infections |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| D014777 |
| Virus Diseases |
| D018352 | Coronavirus Infections |
| D003333 | Coronaviridae Infections |
| D030341 | Nidovirales Infections |
| D012327 | RNA Virus Infections |
| D008171 | Lung Diseases |
| D012140 | Respiratory Tract Diseases |