In clinical practice a lot of EVAR cases are performed IFU for adverse neck anatomy(6) with acceptable short- and mid-term outcomes, but the long-term durability is currently an issue (7). Neck length shorter than 15 mm and angulation are two of. neck charteristics. that contribute more to define an "hostile neck" (8). The issue linked to the anatomical not feasibility of standard EVAR in patients not eligible for OR can be solved with custom made devices (CMD), but they were limited by high production costs and long time for creations (10-12 weeks)1. Nowadays no one off-the-shelf device aimed to overcome neck hostility in AAA is available on the market.
The present study aims at evaluating the anatomical applicability of an off-the-shelf scalloped stent-graft to treat infrarenal AAA with a short and/or angulated neck.
Endovascular aneurysm repair (EVAR) is currently accepted as the preferred choice to treat abdominal aortic aneurysms (AAA) with feasible anatomy. Although approximately 40-60% of AAA patients are not considered anatomically feasible for EVAR, mainly in reason of a "hostile neck anatomy". In ''real-world'' clinical practice, up to 44% of EVAR cases are performed outside Instruction For Use (IFU) for adverse neck anatomy. The off-label use of standard EVAR is currently used for patients who are not eligible for OR, with acceptable short- and mid-term outcomes, Endovascular aneurysm repair (EVAR) is currently accepted as the preferred choice to treat the abdominal aortic aneurysms (AAA) with feasible anatomy. Although approximately 40-60% of AAA patients are not considered anatomically feasible for EVAR, mainly in reason of a "hostile neck anatomy"3-5. In ''real-world'' clinical practice, up to 44% of EVAR cases are performed outside Instruction For Use (IFU) for adverse neck anatomy. The off-label use of standard EVAR is currently used for patients who are not eligible for OR, with acceptable short- and mid-term outcomes, but the long-term durability of EVAR depends on the maintenance of the seal between the endograft and the aortic neck as well as the iliac arteries. Some aortic neck characteristics contribute to the definition of ''hostile neck,'' particularly length shorter than 15 mm and angulation among others. From a recent Consensus Conference, the influence of each characteristic on early or late EVAR failure is not clear, but hostile neck morphology is generally associated with higher rates of aneurysm-related adverse events and mortality. A recent independent Expert Panel, applying the Delphi methodology Indeed, agreed to define 10 mm as the threshold value below which standard EVAR should not be considered feasible. Moreover, the same experts agreed on the fact that an angulation above 60° is considered a hostile criterion for EVAR procedure. Finally should be considered that some "hostility" factors can be present at the same time and create the ideal condition for EVAR failure. The issue linked to the anatomical not the feasibility of standard EVAR in patients not eligible for OR can be solved with custom made devices (CMD), but they were limited by high production costs and long time for creations (10-12 weeks)1. Nowadays no one off-the-shelf device aimed to overcome neck hostility in AAA is available on the market.
The present study aims at evaluating the anatomical applicability of an off-the-shelf scalloped stent graft to treat infrarenal AAA with a short and/or angulated neck. From an informal review of some CTA of patients treated with EVAR or OR in mentioned unit, the authors found that more the 20% presented a distance between the two renal arteries more than 5mm. The idea of an "off-the-shelf" graft with a single scallop theoretically had to permit to gain some length along the aortic neck. Furthermore also in the case of angulation, a single scallop theoretically reduced the risk of bird beck and gutter. The aim of the study is to evaluate if a single scalloped "off-the-shelf" stent graft could be appliable and feasible in an adequate number of patients.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients ttreatted for AAA | Patients affected by AAA and treated att our institution with EVAR and/or Open Repair between 2010 and 2020 |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| CTA evaluation | Other | Any pre-operattive CTA of the patients of the cohort will be carefully evaluated to determine the theoric anatomical feasibility of an off the shelf Endograft, particularly in patients with an angulated and short aortic neck |
| Measure | Description | Time Frame |
|---|---|---|
| Anatomica feasibility and applicability of an "off-the-shelf" scallopped stent-graft measured mesured fitting three device model with data recorded from CTA of patients with AAA treted in our unit | observational study on the anatomical applicability in the coordinator center of an off-the-shelf scalloped device to treat infrarenal AAA with short and/or angulated neck. 3 different endograft designs were constructed. The preoperative measurements were made according to a previously described methodology. The models were matched with each preoperative CTA measure in order to evaluate if they fit or not in the index patients. | 6-months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
All patients affected by AAAs and electively treated with EVAR or OR in the Vascular Surgery Unit of Modena e Reggio Emilia from 2010 to 2020 were considered eligible for the ex-vivo feasibility study. Mandatory condittion for tthhe enrollemnt is an available 2.5mm CTA.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| AOU di Modena, OCB | Baggiovara | Modena | 411266 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30528142 | Background | Wanhainen A, Verzini F, Van Herzeele I, Allaire E, Bown M, Cohnert T, Dick F, van Herwaarden J, Karkos C, Koelemay M, Kolbel T, Loftus I, Mani K, Melissano G, Powell J, Szeberin Z, Esvs Guidelines Committee, de Borst GJ, Chakfe N, Debus S, Hinchliffe R, Kakkos S, Koncar I, Kolh P, Lindholt JS, de Vega M, Vermassen F, Document Reviewers, Bjorck M, Cheng S, Dalman R, Davidovic L, Donas K, Earnshaw J, Eckstein HH, Golledge J, Haulon S, Mastracci T, Naylor R, Ricco JB, Verhagen H. Editor's Choice - European Society for Vascular Surgery (ESVS) 2019 Clinical Practice Guidelines on the Management of Abdominal Aorto-iliac Artery Aneurysms. Eur J Vasc Endovasc Surg. 2019 Jan;57(1):8-93. doi: 10.1016/j.ejvs.2018.09.020. Epub 2018 Dec 5. No abstract available. | |
| 28390913 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Nov 15, 2021 | Nov 1, 2022 | Prot_SAP_000.pdf |
Not provided
| ID | Term |
|---|---|
| D001014 | Aortic Aneurysm |
| ID | Term |
|---|---|
| D000783 | Aneurysm |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D001018 | Aortic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| Background |
| Gimenez-Gaibar A, Gonzalez-Canas E, Solanich-Valldaura T, Herranz-Pinilla C, Rioja-Artal S, Ferraz-Huguet E. Could Preoperative Neck Anatomy Influence Follow-up of EVAR? Ann Vasc Surg. 2017 Aug;43:127-133. doi: 10.1016/j.avsg.2016.12.011. Epub 2017 Apr 6. |
| 28258015 | Background | Caradu C, Berard X, Midy D, Ducasse E. Influence of Anatomic Angulations in Chimney and Fenestrated Endovascular Aneurysm Repair. Ann Vasc Surg. 2017 Aug;43:104-114. doi: 10.1016/j.avsg.2017.01.002. Epub 2017 Feb 28. |
| 25011083 | Background | Speziale F, Sirignano P, Setacci F, Menna D, Capoccia L, Mansour W, Galzerano G, Setacci C. Immediate and two-year outcomes after EVAR in "on-label" and "off-label" neck anatomies using different commercially available devices. analysis of the experience of two Italian vascular centers. Ann Vasc Surg. 2014 Nov;28(8):1892-900. doi: 10.1016/j.avsg.2014.06.057. Epub 2014 Jul 7. |
| 29248241 | Background | Muhs BE, Jordan W, Ouriel K, Rajaee S, de Vries JP. Matched cohort comparison of endovascular abdominal aortic aneurysm repair with and without EndoAnchors. J Vasc Surg. 2018 Jun;67(6):1699-1707. doi: 10.1016/j.jvs.2017.10.059. Epub 2017 Dec 18. |
| 29802043 | Background | AbuRahma AF, DerDerian T, AbuRahma ZT, Hass SM, Yacoub M, Dean LS, Abu-Halimah S, Mousa AY. Comparative study of clinical outcome of endovascular aortic aneurysms repair in large diameter aortic necks (>31 mm) versus smaller necks. J Vasc Surg. 2018 Nov;68(5):1345-1353.e1. doi: 10.1016/j.jvs.2018.02.037. Epub 2018 May 22. |
| 12021728 | Background | Chaikof EL, Fillinger MF, Matsumura JS, Rutherford RB, White GH, Blankensteijn JD, Bernhard VM, Harris PL, Kent KC, May J, Veith FJ, Zarins CK. Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair. J Vasc Surg. 2002 May;35(5):1061-6. doi: 10.1067/mva.2002.123991. No abstract available. |
| 31394211 | Background | Marone EM, Freyrie A, Ruotolo C, Michelagnoli S, Antonello M, Speziale F, Veroux P, Gargiulo M, Gaggiano A. Expert Opinion on Hostile Neck Definition in Endovascular Treatment of Abdominal Aortic Aneurysms (a Delphi Consensus). Ann Vasc Surg. 2020 Jan;62:173-182. doi: 10.1016/j.avsg.2019.05.049. Epub 2019 Aug 6. |
| 32063442 | Background | Gallitto E, Faggioli G, Spath P, Pini R, Mascoli C, Ancetti S, Stella A, Abualhin M, Gargiulo M. The risk of aneurysm rupture and target visceral vessel occlusion during the lead period of custom-made fenestrated/branched endograft. J Vasc Surg. 2020 Jul;72(1):16-24. doi: 10.1016/j.jvs.2019.08.273. Epub 2020 Feb 13. |
| 29268916 | Result | Chaikof EL, Dalman RL, Eskandari MK, Jackson BM, Lee WA, Mansour MA, Mastracci TM, Mell M, Murad MH, Nguyen LL, Oderich GS, Patel MS, Schermerhorn ML, Starnes BW. The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg. 2018 Jan;67(1):2-77.e2. doi: 10.1016/j.jvs.2017.10.044. |