This is a post - market study with a wound dressing, a CE-marked medical device available on the european market. The device will be used in routine clinical practice, i.e. within its intended purpose and without any additional invasive or stressing examinations for the patients.
Up to 36 adult patients with wounds suitable to be treated with the medical device and meeting the inclusion/exclusion criteria will be enrolled at two participating German sites.
During 5 on-site visits within 28 days routine weekly dressing changes the Health Care Professional will examine the wound and will perform required wound care and dressing changes. Pictures of the wound with and without dressing will be taken at each visit and used for automatic analysis. The subjects will be asked to rate their general wound pain and the pain perceived during dressing changes. A wound-related quality of life questionnaire will be presented to the subjects twice and the subject and HCP will rate their safisfaction with the product.
This Post Market Clinical Follow up (PMCF) study will examine product features of the CE-marked wound dressing after having received market authorization regarding the fulfilment of predefined requirements for the successful management of skin integrity during wound care. The primary purpose of this study is to evaluate clinical safety and performance of the product when used on several wounds in routine wound care without any additional invasive or burdensome methods and within the intended use.
As primary objective the dressing´s absorption performance and its ability to prevent exudate accumulation in the wound will be investigated. Further, device disintegration, need of debridement, wound and skin conditions, treatment related pain, general wound pain, dressing adhesion and quality of life as well as Helath Care professional's (HCP´s) and patient´s satisfaction are considered as secondary outcomes.
In total, 36 eligible subjects will be enrolled at 2 German sites, including 15 % dropouts.
5 on-site visits are to be performed by the subjects in the scope of routine weekly wound care/dressing change visits during 28 days (Day 0, Day7, Day 14, Day21, Day28). The IMD will be applied during each on-site visit including wound care, wound examination/documentation and dressing change according to HCP's judgment and individual circumstances of the wound. Photographic documentation of the wound and the wound with applied dressings will be performed and used for further automatic wound/tissue analyis. General wound pain as well as pain perceived during dressing change will be documented, as well as Wound-related Quality of life as well as Patient's/HCP's satisfaction with the product.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Cutimed® Gelling Fiber | Device | application of dressing |
| Measure | Description | Time Frame |
|---|---|---|
| Exudate absorption by IMD ('yes', 'no') | Percentage of subjects with exudate absorbed by the IMD per visit | day 7 |
| Exudate absorption by IMD ('yes', 'no') | Percentage of subjects with exudate absorbed by the IMD per visit | day 14 |
| Exudate absorption by IMD ('yes', 'no') | Percentage of subjects with exudate absorbed by the IMD per visit | day 21 |
| Exudate absorption by IMD ('yes', 'no') | Percentage of subjects with exudate absorbed by the IMD per visit | day 28 |
| Exudate accumulation in the wound by IMD ( 'no', 'minimal amount', 'medium amount', 'high amount') | Percentage of subjects with remaining exudate in wound per amount and visit | day 7 |
| Exudate accumulation in the wound by IMD ( 'no', 'minimal amount', 'medium amount', 'high amount') | Percentage of subjects with remaining exudate in wound per amount and visit | day 14 |
| Exudate accumulation in the wound by IMD ( 'no', 'minimal amount', 'medium amount', 'high amount') | Percentage of subjects with remaining exudate in wound per amount and visit | day 21 |
| Exudate accumulation in the wound by IMD ( 'no', 'minimal amount', 'medium amount', 'high amount') |
| Measure | Description | Time Frame |
|---|---|---|
| Changes in need for debridement | Percentage of subjects with need for debridement per visit | Throughout days 0, 7, 14, 21 and 28 |
| Changes in debridement ease | Percentage of subjects per debridement ease ('easy', 'moderate', 'heavy', 'not applicable') per visit |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Representativeness of the investigation population is assumed to be high in relation to the target population since this is a PMCF study, where the IMD will be used within the intended purpose including the intended patient population. Therefore, the IMD will be tested by the population for whom it is in fact intended for once placed on the market among other intended users. Inclusion and exclusion criteria are aligned with the product´s intended purpose.
No vulnerable subjects such as children, pregnant women, or sponsors or manufacturers staff will participate in this study guaranteed by specific inclusion and exclusion criteria.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Arne Böhling, Dr. | BSN Medical GmbH | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Christliches Klinikum Melle GmbH, Unfallchirurgie | Melle | 49324 | Germany |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Percentage of subjects with remaining exudate in wound per amount and visit |
| day 28 |
| Throughout days 0, 7, 14, 21 and 28 |
| Changes in wound margin condition | Percentage of subjects per wound margin condition('intact', 'macerated', 'redness', 'ragged') per visit | Throughout days 0, 7, 14, 21 and 28 |
| Changes in peri-wound skin condition | Percentage of subjects per peri-wound skin condition ('intact', 'macerated', 'redness', 'dry/flaky', 'edematous' ,'weeping') per visit | Throughout days 0, 7, 14, 21 and 28 |
| Changes in wound tissue type | Percentage of subjects per wound tissue type ('epithelialization tissue', 'granulation tissue', 'slough', 'eschar/necrotic tissue', 'other') per visit | Throughout days 0, 7, 14, 21 and 28 |
| Ease of application | Percentage of subjects per ease of application ('very easy', 'easy', 'difficult', 'very difficult') per visit | Throughout days 0, 7, 14, 21 and 28 |
| Conformability during application | Percentage of subjects per conformability ('very good', 'good', 'poor', 'very poor') per visit | Throughout days 0, 7, 14, 21 and 28 |
| Ease of removal | Percentage of subjects per ease of removal ('very easy', 'easy', 'difficult', 'very difficult') per visit | Throughout days 7, 14, 21 and 28 |
| Dressing adherence on removal | Percentage of subjects per adherence ('none', 'minor', 'moderate', 'marked') per visit | Throughout days 7, 14, 21 and 28 |
| Pain on removal | Mean pain perceived by subject using a pain ruler (scale 0-10) per visit | Throughout days 7, 14, 21 and 28 |
| Changes in wound-pain | Mean pain perceived by subject using a pain ruler (scale 0-10) per visit | Throughout days 7, 14, 21 and 28 |
| Changes in Wound-quality of life Wound-QoL | percentage change in Wound-QoL total scores and subscale scores ('body', 'psyche', 'everyday life' and standalone item) between both visits | Day 0 and Day 28 |
| HCP Overall satisfaction | Percentage per HCP overall satisfaction category ('Very good', 'Good', 'Satisfactory', 'Sufficient', 'Insufficient') for final visit | day 28 |
| Subject Overall satisfaction | Percent of patient overall satisfaction category ('Very good', 'Good', 'Satisfactory', 'Sufficient', 'Insufficient') for all patients at visit 5 | day 28 |
| Incidence of adverse events related to IMD | Total occurence of IMD related adverse events | Throughout days 0, 7, 14, 21 and 28 |
| Incidence of device disintegration (removability in one piece) | Total occurence of IMD disintegration during removal | Throughout days 0, 7, 14, 21 and 28 |
| ID | Term |
|---|---|
| D007871 | Leg Ulcer |
| D017719 | Diabetic Foot |
| D003668 | Pressure Ulcer |
| D000072836 | Surgical Wound |
| D022125 | Lacerations |
| D002056 | Burns |
| ID | Term |
|---|---|
| D012883 | Skin Ulcer |
| D012871 | Skin Diseases |
| D017437 | Skin and Connective Tissue Diseases |
| D003925 | Diabetic Angiopathies |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D016523 | Foot Ulcer |
| D048909 | Diabetes Complications |
| D003920 | Diabetes Mellitus |
| D004700 | Endocrine System Diseases |
| D003929 | Diabetic Neuropathies |
| D014947 | Wounds and Injuries |