This study aimed to determine the effect of virtual reality on pain, anxiety, and vital signs of oncology patients undergoing port catheter implantation. The study was carried out with 139 participants (69 intervention, 70 control) between September 2019 and January 2020. A patient identification form, state anxiety inventory, a table for vital signs, and a visual analog scale for pain severity were used for the data collection. Data were collected from the patients before, during, and after the implantation. In the intervention group, a virtual reality device, movies, and relaxing music were provided to the patients.
To determine the effect of virtual reality (VR) on pain, anxiety, and vital signs of oncology patients undergoing port catheter implantation. The study was a randomized controlled study. The study was carried out with 139 participants (69 intervention, 70 control) between September 2019 and January 2020. Data were collected before, during, and after the implantation by using a patient identification form, State Anxiety Inventory (SAI), a table for vital signs, and a visual analog scale for pain severity. In the intervention group, a virtual reality device, movies, and relaxing music were provided and patients were instructed to use it during the implantation and when they felt pain after the implantation. Data of the study were analyzed with IBM SPSS v25.0.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Intervention | Experimental | For the patients in this group, a virtual reality device was provided to the patients and patients wear it during the port catheter implantation and after the port catheter implantation when they felt pain. |
|
| Control | No Intervention | For the patients in this group, there wasn't any specific intervention during or after the port catheter implantation. |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Virtual Reality Distraction | Other | The patients were administered to use the virtual reality device and they were free to choose the theme and video in the library to watch. Patients used the device during the port catheter implantation and untill the 4 hour after the implantation when they felt pain. |
| Measure | Description | Time Frame |
|---|---|---|
| Pain Severity | A visual analog scale was used the examine the pain of the patients. Patients mark the severity of their experiences on 10 cm lines and the beginning of the line shows the lowest degree of the experience while the end of the line shows the highest. This scale is frequently used to determine the severity of the patient's pain. In this study, a 10 cm line was used to assess the severity of the patient's pain. While 0 reflects no pain, 10 reflects the highest severity of the pain. VAS was used for both groups before and after the port catheter implantation. | Change from baseline pain severity at 4 hours |
| Anxiety | State anxiety inventory was used to examine the patients' anxiety. The scale was by Spielberger et al (1970). The Cronbach's Alpha internal consistency coefficients were range between .83 and .87. The State Anxiety Scale is a 20-item scale about how an individual feels at the moment. Originally, the scale consisted of two main domains, state anxiety, and trait anxiety. Only one of these two domains, state anxiety, was used in this study. The scores on the scale range between 20 and 80. Higher points reflect higher levels of anxiety. The scale was reported valid and reliable for Turkish society. The Cronbach's Alpha of the Turkish version was reported between 0.94 and 0.96. The scale was used for both groups before and after the port catheter implantation. | Change from baseline anxiety levels at 4 hours |
| Blood Pressure (Systolic and Diastolic) | The blood pressure of the patients was assessed by using the Con-Tec CMS5100 device. The results presented as mmHg. The blood pressure measuring was administered for the patients in both groups. | Change from the baseline blood pressure at 4 hours |
| Heart Rate | Heart rates were assessed by using the Con-Tec CMS5100 device. Beat per minute was used for comparison. Heart rates were measured for both groups. | change from baseline heart rate at 4 hours |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| TuÄŸba Menekli, Ph.D. | TuÄŸba Menekli | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| İnönü Üniversitesi | Malatya | 44100 | Turkey (Türkiye) |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D010146 | Pain |
| D001008 | Anxiety Disorders |
| D001832 | Body Temperature Changes |
| ID | Term |
|---|---|
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D001523 | Mental Disorders |
Not provided
Not provided
The study was of a randomized controlled design. There were two groups in the study; intervention and control. For the intervention group, the virtual reality distraction method was administered to the patients during the port catheter implantation in the intervention group while it wasn't administered to the patients in the control group.
Not provided
Not provided
There wasn't a masking in the study.
|
| Respiratory Rate | The respiratory rate was assessed by using the Con-Tec CMS5100 device. Respiration (inhalation and exhalation) per minute was used for comparison. The respiratory rate was measured for both groups. | change from baseline respiratory rate at 4 hours |
| O2 saturation | O2 saturation was assessed by using the Con-Tec CMS5100 device. O2% were used for comparison. O2 Saturation was measured for both groups. | change from baseline O2 saturation at 4 hours |