Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Alcon Research | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Some parameters, such as a change in the optic tilt and axial decentration, can affect the optical characteristics of intraocular lenses (IOLs) in postoperative period, which leads to residual refractive errors and other complications.
The stability of the intraocular lens in the eye is largely dependent on the mechanical design of its haptic support elements. Thus, the new Clareon IOL has a flat haptic with a flexible design that minimizes axial changes and allows the IOL to maintain a stable position in a given plane during compression.
Currently there is no published data of the stability for Clareon AutonoMe IOL for long eyes.
The purpose of the current study is to evaluate and compare the axis displacement and stability of optical tilt, visual and refractive results in patients after implantation of two different models of intraocular lenses: Clareon AutonoMe (Alcon, USA) and Hoya iSert 251 (Japan) in the long-term postoperative period (after cataract surgery).
The optical performance of intraocular lenses (IOLs) can be affected by changes in optic tilt and decentration that occur after implantation, resulting in residual refractive errors and other complications. Intraocular lens stability is largely dependent on the mechanical design of the haptics. Clareon IOL has a flat haptic with a flexible design that minimizes axial changes and allows the IOL to maintain a stable position in a given plane during compression.
Based on our knowledge, nobody has compared Clareon AutonoMe and Hoya iSert 251 IOLs in clinical setting.
Scientific Rationale:
This study investigates the stability of IOLs in patients with long axial length. IOL stability on long eyes has a limited clinical data, no in Vivo research has been done. It is known that eyes with long axial length have a large capsule bag. With such eyes, it is difficult to predict the effective lens position.
Each 0,5 mm axial displacement lead to approximately 0,5 D of the refractive error.
For long eyes, it is important to use the latest generation of multi-component IOL calculation formulas for accurately prediction of effective lens position.
The mail purpose of the study is to evaluate and compare the axis displacement and stability of optical tilt, visual and refractive results in patients after implantation of two different models of intraocular lenses: Clareon AutonoMe (Alcon, USA) and Hoya iSert 251 (Japan) in the long-term postoperative period (after cataract surgery).
The research purpose is to evaluate the prediction error for each IOL calculation formula (Barrett Universal II, Kane, EVO, Holladay I with Van Koch correction)
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| IOL Clareon AutonoMe | Experimental | The first group of patients (39 eyes) who received the monofocal IOL Clareon AutonoMe after the phacoemulsification of cataract. |
|
| IOL Hoya iSert 251 | Active Comparator | the second group of patients (39 eyes) who received the monofocal IOL Hoya iSert 251 after the phacoemulsification of cataract |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| IOL Clareon AutonoMe | Procedure | Phacoemulsification of cataract with implantation of two types of IOLs - Clareon AutonoMe and Hoya iSert 251. Operations will be performed by one surgeon using the Centurion vision system under control of the Verion navigation system. The Verion system will be used for capsulorhexis and IOL centration (limbus centration). |
| Measure | Description | Time Frame |
|---|---|---|
| Intraocular lens axial displacement | Axial displacement of the intraocular lens, stable position of the intraocular lens in the capsule bag after surgery, optics tilt, deviation from baseline, the distance from the corneal epithelium to the anterior surface of the intraocular lens, the stretching degree of the surgical wound will be assessed by the anterior segment OCT (AS-OCT). | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Near and distance vision visual acuity | Improving the clarity of images of observed objects. For one focus distance (reading and working at near / far (depending on the calculation of the IOL for emmetropia or weak myopic refraction) / intermediate distance, it is possible to use spectacle correction in the postoperative period. | 6 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Boris E Malyugin, MD, PhD | The S. Fyodorov Eye Microsurgery Federal State Institution | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| The S. N. Fyodorov Eye Microsurgery Federal State Institution | Moscow | 127486 | Russia |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 14967267 | Background | Wirtitsch MG, Findl O, Menapace R, Kriechbaum K, Koeppl C, Buehl W, Drexler W. Effect of haptic design on change in axial lens position after cataract surgery. J Cataract Refract Surg. 2004 Jan;30(1):45-51. doi: 10.1016/S0886-3350(03)00459-0. | |
| 32901830 | Background | Remon L, Cabeza-Gil I, Calvo B, Poyales F, Garzon N. Biomechanical Stability of Three Intraocular Lenses With Different Haptic Designs: In Silico and In Vivo Evaluation. J Refract Surg. 2020 Sep 1;36(9):617-624. doi: 10.3928/1081597X-20200713-02. |
Not provided
Not provided
We plan to share Clinical Study Report, present and publish results of the study.
During the study and after.
upon request
Not provided
Not provided
The first group of patients will receive the IOL Clareon AutonoMe (Alcon, USA), and the second group of patients will receive the IOL Hoya iSert 251 (Japan), 39 eyes in each group, total 78 patients, 78 eyes.
Not provided
Not provided
Not provided
Not provided
|
| IOL Hoya iSert 251 | Procedure | Phacoemulsification of cataract with implantation of two types of IOLs - Clareon AutonoMe and Hoya iSert 251. Operations will be performed by one surgeon using the Centurion vision system under control of the Verion navigation system. The Verion system will be used for capsulorhexis and IOL centration (limbus centration). |
|
| Patient's subjective satisfaction of with the quality of vision |
Increased subjective satisfaction of patients with the quality of vision after surgery will be assessed using the VF-14 questionnaire (Steinberg E.P., 1994). |
| 6 months |
| Deviation from emmetropic refraction | Accurate IOL calculation before surgery. | 6 months |
| Number of intra- and postoperative complications | Intra- and postoperative complications in the operated eye will be assessed according to the observation data of the research subjects. | 6 months |
| 20884057 | Background | Bang S, Edell E, Yu Q, Pratzer K, Stark W. Accuracy of intraocular lens calculations using the IOLMaster in eyes with long axial length and a comparison of various formulas. Ophthalmology. 2011 Mar;118(3):503-6. doi: 10.1016/j.ophtha.2010.07.008. Epub 2010 Sep 29. |
| 30686704 | Background | Lane S, Collins S, Das KK, Maass S, Thatthamla I, Schatz H, Van Noy S, Jain R. Evaluation of intraocular lens mechanical stability. J Cataract Refract Surg. 2019 Apr;45(4):501-506. doi: 10.1016/j.jcrs.2018.10.043. Epub 2019 Jan 25. |
| ID | Term |
|---|---|
| D009216 | Myopia |
| D001251 | Astigmatism |
| D064090 | Intraocular Lymphoma |
| ID | Term |
|---|---|
| D012030 | Refractive Errors |
| D005128 | Eye Diseases |
| D008223 | Lymphoma |
| D009370 | Neoplasms by Histologic Type |
| D009369 | Neoplasms |
| D005134 | Eye Neoplasms |
| D009371 | Neoplasms by Site |
| D008232 | Lymphoproliferative Disorders |
| D008206 | Lymphatic Diseases |
| D006425 | Hemic and Lymphatic Diseases |
| D007160 | Immunoproliferative Disorders |
| D007154 | Immune System Diseases |
Not provided
Not provided