Fluid are used to increase cardiac output (CO) and blood pressure in patients admitted to the intensive care unit (ICU) .Fluid is an important line of therapy that needed in shocked patient, hypovolemic and following surgery to correct the volume state and avoid acute kidney injury. However, excess fluid administration may be harmful leading itself to increase rates of acute kidney injury (AKI), prolonged days of mechanical ventilation and death . Excess fluid administration may increase right and left atrial pressure leading to congestion and edema.
Increasing cardiac output more than 15% following fluid administration was used as fluid responsiveness method by the Surviving Sepsis Campaign (SSC) guidelines. However, these strategies may promote over-resuscitation as most recommend continuing fluid administration until the patients are no longer VR. VR-based strategies do not assess elevations in right atrial pressure (RAP) or assess for venous congestion which could occur earlier.
The elevations of left atrial pressure can be seen clinically with hypoxia, cephalization on chest X-ray and B-lines on ultrasound resulting from pulmonary edema, while the elevation in right-sided pressure is much more difficult to detect.
It is possible that rightsided venous flow changes detect clinically important elevations in right atrial pressure that lead to venous congestion and end organ injury . Doppler flow patterns of hepatic veins (HV), portal vein (PV) and intra-renal veins (RV) are noninvasive and accurately identify early stages of right-sided venous congestion in patients who have cardiac dysfunction and congestive heart failure with elevated right atrial pressures . If HV, PV and RV can be validated as reliable measures of elevated RAP, such indicators might have utility in modulating fluid resuscitation in other critically ill patient populations.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| doppler US of portal vein, hepatic veins, intrarenal veins | Other | Hepatic Vein Doppler : To obtain the HV PW, a phased array transducer is used with cardiac pre-sets. ECG leads are placed to assist in the interpretation of HVD in sinus rhythm as well as atrial fibrillation. The middle hepatic vein is identified from mid-subcostal or lateral views during the end-expiratory phase of the patients respiratory cycle. Portal vein Doppler: From a lateral costal or subcostal window, the portal vein is identified in the coronal plane using a phased-array transducer. The PV were considered abnormal if the pulsatilty index was greater than 30%. The portal pulsatility index was defined as: (VMax - VMin/VMax) * 100%. Here, VMax is the maximal velocity and VMin is the minimal velocity during the cardiac cycle. Intra-renal venous Doppler: From lateral costal window, the kidney is located in the coronal plane and a color flow box placed over the distal renal calyceal junction to cortex. |
| Measure | Description | Time Frame |
|---|---|---|
| Changes in Doppler flow patterns of hepatic veins (HV), portal vein (PV) and intra-renal veins (RV) in critically ill patients and their relations to the patients' volume state. | hepatic veins (HV), portal vein (PV) and intra-renal veins doppler changes in critically ill patients | 1 year |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
- Adult patients who admitted to critical care unit and intermediate critical care unit of Internal medicine department after obtaining consent
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Mohammed Alyamany Kobeisy, MD | Contact | 01002228914 | mohamed.hussien10@med.au.edu.eg | |
| Dina Ali Ahmed Abd El-All, MD | Contact | 01063040703 | dinaalihamad@aun.edu.eg |
Not provided
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 33076961 | Result | Spiegel R, Teeter W, Sullivan S, Tupchong K, Mohammed N, Sutherland M, Leibner E, Rola P, Galvagno SM Jr, Murthi SB. The use of venous Doppler to predict adverse kidney events in a general ICU cohort. Crit Care. 2020 Oct 19;24(1):615. doi: 10.1186/s13054-020-03330-6. |