The Wovex bifurcated dacron vascular prostheses have been available on the French market since 2008. They are mainly used to treat aneurysmal or occlusive aortic diseases. To date, they have not been the subject of a specific clinical efficacy/safety study, unlike other Dacron prostheses used in the same field.
We purpose a monocentric, retrospective, consecutive study based on medical data, including all the patients operated for aneurysms or occlusive disease of the abdominal aorta at Dijon Bourgogne University Hospital between 2013 and 2017 and who received a WOVEX bifurcated prosthesis (Wovex® Polyester Vascular Protheses).
The objective is to explore the safety (short-term postoperative morbidity and mortality at 5 years) and efficacy (primary permeability, secondary permeability and dilatation of the prosthesis at 5 years) of the WOVEX prosthesis.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patient with WOVEX bifurcated prosthesis |
|
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Data collection | Other | demographics co-morbidities risk factors operative, hospital and vascular follow-up data |
|
| Measure | Description | Time Frame |
|---|---|---|
| Safety and security | Occurrence of death or major re-intervention (bypass stenosis/thrombosis, false anastomotic aneurysm, prosthesis infection, anastomosis rupture, amputation) over the entire follow-up period (from date of surgery to study end date (February 28, 2021)) | 5 years |
| Measure | Description | Time Frame |
|---|---|---|
| Major surgical reintervention | bypass stenosis/thrombosis, false anastomotic aneurysm, prosthesis infection, anastomosis rupture, amputation throughout the follow-up period | 5 years |
| Primary permeability |
Not provided
Inclusion Criteria:
Exclusion Criteria:
- Deceased patients who have expressed their refusal of post-mortem processing of their personal health data
Not provided
Not provided
Not provided
Patients operated for aneurysms or occlusive disease of the abdominal aorta at Dijon Bourgogne University Hospital between January, 1st 2013 and December 31, 2017 who received a WOVEX bifurcated prosthesis (Wovex® Polyester Vascular Protheses) from LEMAITRE VASCULAR Society
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Chu Dijon Bourogne | Dijon | 21000 | France |
Not provided
Not provided
Not provided
Not provided
Stenosis/thrombosis of the prosthesis over the entire follow-up period
| 5 years |
| Secondary permeability | Stenosis/thrombosis after reintervention over the entire follow-up period | 5 years |
| Dilatation of the prothesis | Diameter of the prosthesis over the entire follow-up period | 5 years |
| Occurence of MAVE and MACE | Occurence of MAVE and MACCE (re-interventions, ischemic cardiac, neurological (stroke/TIA), pulmonary and renal complications) throughout the follow-up period | 5 years |
| Occurence of adverse events | Other adverse events over the entire follox-up period | 5 years |
| ID | Term |
|---|---|
| D000783 | Aneurysm |
| ID | Term |
|---|---|
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D003625 | Data Collection |
| ID | Term |
|---|---|
| D004812 | Epidemiologic Methods |
| D008919 | Investigative Techniques |
| D017531 | Health Care Evaluation Mechanisms |
| D011787 | Quality of Health Care |
| D017530 | Health Care Quality, Access, and Evaluation |
| D011634 | Public Health |
| D004778 | Environment and Public Health |
Not provided
Not provided